Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: DEV STDS MODIFICATION REVIEW
Permit Number - DS09-08
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/06/2009 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 04/07/2009 | DAVE MANN | FIRE | REVIEW | Approved | |
| 04/07/2009 | RONALD BROWN | ZONING HC SITE | REVIEW | Approved | |
| 04/08/2009 | MATT FLICK | ENGINEERING | REVIEW | Approv-Cond | DS09-08 2nd/Anderson Residences DSD Engineering has no objection or adverse comment to approval of a DSMR for the following: Use of the sidewalk along 2nd Street as part of the continuous pedestrian circulation path. Reduction of onsite circulation width to 3 feet. DSD Engineering CONDITIONALLY APPROVES a DSMR for the following: Use of the 45-degree enclosure option from Anderson Boulevard conditional upon reduction of the slope at the driveway not to exceed two percent (2%). |
| 04/13/2009 | JHERSHE1 | COMMUNITY PLANNING | REVIEW | Approved | URBAN PLANNING AND DESIGN COMMENTS City of Tucson CDRC - Community Design Review Committee CASE NAME & NUMBER: DS09-08, 3148 E. 2nd Street Submittal #: 1 COMMENTS DUE: 4/13/09 REVISED COMMENTS SENT: 4/17/09 Items reviewed: Site Plan DSMR, justification for requests Related: land use plan(s) - N/A Staff has reviewed this proposal, and finds that the project is not part of a rezoning case, and is not an RCP or FLD case. Staff has no comments. REVIEWER: Joanne Hershenhorn DATE: 4/17/09 S:\CASE REVEIW\CDRC_Cases\2009_Reviews\DS09-08_3148_E_Second_St.doc |
| 04/14/2009 | DAVID RIVERA | ZONING | REVIEW | Approved | CDRC TRANSMITTAL FROM: David Rivera Principal Planner DSD Zoning Review Section PROJECT: DSMR-09-08 3148 e 2ND STREET 2ND/Anderson Residences (Site Plan) Development Standard Modification Request Transmittal date: April 14, 2009 COMMENTS: Approved with conditions 1. DS 2-08.3.0 & 2-08.3.1 - approved 2. DS 2-08.5.1.A Conidionally approved per Craig Gross to a minimum width of 42 inches. 3. DS 6-0.0, 4.1, 4.2 approved pending approval by the Traffic engineering and Environmental Services. In the event that Traffic or Environmental Services denies the DSMR request for this standard the zoning approval is void. A re-design, review and approval this area may be required if this standard is denied.) If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. ` |
| 04/15/2009 | ANDY VERA | ENV SVCS | REVIEW | Approv-Cond | 1. No objections to the placement of the solid waste enclosure or the access and approach to the area. 2. However, the trash enclosure diagram provided must include provisions for the gates to be secured in the open and closed positions. DS 6-01.4.2.C.4. Recommend showing within diagram and annotate "Positive locking with (Bayonet) anchors, Qty. 4/ 1 inch dia. x 6 inch long galvanized pipe flush in concrete/foundation." If you have any questions you may contact Andy Vera at (520) 791-5543 ext 1212 or e-mail: Andy.Vera@tucsonaz.gov |
| 04/15/2009 | JOSE ORTIZ | TRAFFIC | TRAFFIC | Approved | |
| 04/16/2009 | PATRICIA GEHLEN | ZONING-DECISION LETTER | WRITE DECISION LETTER | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE CITY OF TUCSON - DEVELOPMENT SERVICES April 16, 2009 Wally Gasser WG Gasser Design 3102 East Seneca Street Tucson, Arizona 85716 Re: DSMR 09-08 - 3148 East 2nd Street (T09CM00312) Request: DS 2-08.3.1 - Modify Development Standards to allow sidewalk in 2nd Street right-of-way to act as on-site pedestrian circulations system north of units 5, 6, and 7, DS 2-08.5.1.A - Modify Development Standards to allow on site pedestrian circulation system on be a minimum of 42" wide, DS 6-01 - Modify ESD standard per attached description. The Development Standard Modification Requests (DSMRs) listed above has been APPROVED by the CRDC committee with the following conditions: 1) Use of the 45-degree enclosure option from Anderson Boulevard conditional upon reduction of the slope at the driveway not to exceed two percent (2%), 2) The trash enclosure diagram provided must include provisions for the gates to be secured in the open and closed positions. PLEASE NOTE THAT A GENERAL NOTE MUST BE ADDED TO THE SITE PLAN WHICH STATES THE DSMR CASE NUMBER, DATE OF APPROVAL, MODIFICATIONS GRANTED, AND CONDITIONS IMPOSED. IN ADDITION, THE CASE NUMBER MUST BE ADDED TO EACH SHEET OF THE SITE PLAN, LANDSCAPE PLAN, AND NPPO PLAN, IN THE LOWER RIGHT CORNER NEAR THE TITLE BLOCK. If you have any additional questions, please contact me at 837-4919. Sincerely, Patricia Gehlen Zoning/CDRC Manager Development Services Department Attachments: 1 XC: file Records Fax 867-8121 |