Permit Review Detail
Review Status: Completed
Review Details: DEV STDS MODIFICATION REVIEW
Permit Number - DS08-59
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/10/2008 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 12/11/2008 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 12/11/2008 | RONALD BROWN | ZONING HC SITE | REVIEW | Approv-Cond | THE SITE WAS REVIEWED FOR 100% COMPLIANCE AS PER ZONING DEPARTMENT EVALUATION NOT JUST FOR PARKING LOT RECONSTRUCTION. CONDITIONAL APPROVAL BASED UPON ZONING REVIEW AND APPROVAL. |
| 12/12/2008 | MATT FLICK | ENGINEERING | REVIEW | Approved | DS 3-05.2.1.C.1 -- PAAL south of Bldg F. DS 3-05.2.2.B.1 -- Pedestrian refuge/sidewalk along PAAL adjacent to Bldgs. F & G. |
| 12/12/2008 | DAVID RIVERA | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL FROM: David Rivera Principal Planner DSD Zoning Review Section PROJECT: DSMR-08-59 2835 N Stone Avenue Vidas Serenas Apartments Development Standard Modification Request Transmittal date: December 12, 2008 COMMENTS: Conditional Approval of DS 3.05.2.2.B.1, Denied - 3.05.2.1.C.1 1. DS 3-05.2.1.C.1 cannot be supported or approved. A modification to a PAAL width must be approved through a Board of Adjustment Variance. (The section requested for a modification is for a one way PAAL that also would provide Fire Access.) 2. The modification to reduce or eliminate the pedestrian refuge requirement is conditionally approved: building G (reduce the refuge area), the existing building next bldg G (eliminate the refuge area), and the pedestrian refuge area along the southwest corner of building F (eliminate the refuge area). Conditions of approval: A. Construct a sidewalk along building G. B. Provide the circulation to the buildings where the refuge is eliminated via the routes highlighted on the plan. Demonstrate on the site plan the proposed continuous pedestrian circulation by key notes. If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. |
| 12/15/2008 | JOSE ORTIZ | TRAFFIC | TRAFFIC | Approved | |
| 12/17/2008 | ANDY VERA | ENV SVCS | REVIEW | Approved | ES has no objections to this request as it pertains to solid waste collections/disposal. |
| 12/17/2008 | PATRICIA GEHLEN | ZONING-DECISION LETTER | WRITE DECISION LETTER | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE CITY OF TUCSON - DEVELOPMENT SERVICES December 17, 2008 J. Lorenzo Ortiz, P.E. DOWL HKM 166 West Alameda Tucson, Arizona 85701 Re: DSMR 08-59 - 2835 North Stone Avenue (T08CM03039) Request: DS 3-05.2.2.B.1 - Modify Development Standards to allow less than five (5) between a building and a PAAL as shown on the site plan and detailed in the on-line Zoning comments. The Development Standard Modification Request (DSMR) listed above has been APPROVED by the CRDC committee with the following conditions: 1) Construct a sidewalk along building G, 2) Provide the circulation to the buildings where the refuge is eliminated via the routes highlighted on the plan. Demonstrate on the site plan the proposed continuous pedestrian circulation by key notes. Request: DS 3-05.2.1.C.1 - Modify Development Standards to allow a PAAL to be reduced to less than 24 feet in width. The Development Standard Modification Request (DSMR) listed above has been DENIED by the CRDC committee per the on-line comments. THE PAAL IN QUESTION (SOUTH OF BUILDING F) IS CONSIDERED NON-CONFORMING PER ZONING ADMINISTRATOR E-MAIL DATED 12/15/2008. PLEASE NOTE THAT A GENERAL NOTE MUST BE ADDED TO THE DEVELOPMENT PLAN WHICH STATES THE DSMR CASE NUMBER, DATE OF APPROVAL, MODIFICATIONS GRANTED, AND CONDITIONS IMPOSED. IN ADDITION, THE CASE NUMBER MUST BE ADDED TO EACH SHEET OF THE DEVELOPMENT PLAN, LANDSCAPE PLAN, AND NPPO PLAN, IN THE LOWER RIGHT CORNER NEAR THE TITLE BLOCK. If you have any additional questions, please contact me at 837-4919. Sincerely, Patricia Gehlen Zoning/CDRC Manager Development Services Department Attachments: 1 XC: file Records Fax 624-0384 |
| 12/17/2008 | PGEHLEN1 | COMMUNITY PLANNING | REVIEW | Passed | due to hard zoning |