Permit Number: DS08-54
Parcel: 12616319D

Address: Unknown

Review Status: Completed

Review Details: DEV STDS MODIFICATION REVIEW

Permit Number - DS08-54
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/18/2008 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
11/18/2008 RONALD BROWN ZONING HC SITE REVIEW Approved
11/19/2008 JOSE ORTIZ TRAFFIC TRAFFIC Approved
11/20/2008 DAVE MANN FIRE REVIEW Approved
11/20/2008 MATT FLICK ENGINEERING REVIEW Denied Since 1999, Mayor and Council has established a policy that all sidewalks be constructed to a width of six feet (6'). Accordingly, TDOT established a policy of increasing sidewalk widths along arterials for spot improvements if the length exceeds one hundred feet (100'). The length along this project is about four hundred feet (400') and should be increased in width to 6' in accordance with Mayor & Council policy. Adequate right-of-way exists for the installation of the wider sidewalk.
11/20/2008 DAVID RIVERA ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

FROM: David Rivera
Principal Planner
DSD Zoning Review Section
PROJECT: DSMR-08-54
431 N Alvernon Way
Double Tree Hotel
Development Standard Modification Request

Transmittal date: November 20, 2008

COMMENTS: Approved with conditions

1. Zoning supports the Modification pending approval by TDOT and DSD Engineering. IF TDOT or Engineering deny the DSMR the Zoning approval is void.


If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.
11/25/2008 ANDY VERA ENV SVCS REVIEW Approved ES has no objections to this request as it pertains to solid waste disposal.
11/28/2008 JOHN BEALL COMMUNITY PLANNING REVIEW Approved DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Development Standard Modification Request (DSMR)

CASE NUMBER: CASE NAME: DATE SENT

DS-08-54 431 Alvernon Way 12/1/08

( ) Tentative Plat
(XXXX) Development Plan
( ) Landscape Plan
( ) Revised Plan/Plat
( ) Board of Adjustment
( ) Other - Site Plan

CROSS REFERENCE: D08-0036 & C9-72-72

NEIGHBORHOOD PLAN: Alvernon-Broadway

GATEWAY/SCENIC ROUTE: N.A.

COMMENTS DUE BY: 11/25/08

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

(XXXX) Proposal Complies with Annexation or Rezoning Conditions



REVIEWER: drcorral 791-4505 DATE: 11/25/08
12/03/2008 PATRICIA GEHLEN ZONING-DECISION LETTER WRITE DECISION LETTER Denied COMMUNITY DESIGN REVIEW COMMITTEE
CITY OF TUCSON - DEVELOPMENT SERVICES

December 3, 2008

Steve Oliverio
The WLB Group
4444 East Broadway Blvd.
Tucson, Arizona 85711

Re: DSMR 08-54 - 431 South Alvernon Way (D08-0036)

Request: DS 3-01.3.3.A - Modify Development Standards to allow a less than six foot sidewalk in the Alvernon Way right-of-way.

The Development Standard Modification Request (DSMR) listed above has been DENIED by the CRDC committee per the on-line comments.




PLEASE NOTE THAT A GENERAL NOTE MUST BE ADDED TO THE DEVELOPMENT PLAN WHICH STATES THE DSMR CASE NUMBER, DATE OF APPROVAL, MODIFICATIONS GRANTED, AND CONDITIONS IMPOSED. IN ADDITION, THE CASE NUMBER MUST BE ADDED TO EACH SHEET OF THE DEVELOPMENT PLAN, LANDSCAPE PLAN, AND NPPO PLAN, IN THE LOWER RIGHT CORNER NEAR THE TITLE BLOCK.


If you have any additional questions, please contact me at 837-4919.

Sincerely,


Patricia Gehlen
Zoning/CDRC Manager
Development Services Department

Attachments: 1
XC: file
Records

Fax 881-7492