Review Date Reviewer's Name Type of Review Description Status Comments
09/15/2008 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
09/16/2008 RONALD BROWN ZONING HC SITE REVIEW Approved
09/17/2008 CARL SCHULTZ FIRE REVIEW Approved
09/19/2008 JOSE ORTIZ TRAFFIC TRAFFIC Approved
09/22/2008 MATT FLICK ENGINEERING REVIEW Approved DSD Engineering has no objection or adverse comment to approval of a DSMR for a portion of Sec. 4.3.1 in Dev. Std. 10-01 (Detention/Retention Manual) as follows:

No objection to sideslopes being continuous and uniform or exceeding 20% of the basin perimeter.

Since it is stated that the basin is not multi-use, multi-use basin requirements do not apply. Single-purpose basins are permitted by the Dev. Std. There is no requirement for the basin to be natural looking. Visual quality requirements remain in force except as modified by the DSMR.
09/22/2008 DAVID RIVERA ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

FROM: David Rivera for Joseph Linville - Landscape Review Section
Principal Planner
DSD Zoning Review Section
PROJECT: DSMR-08-45
266 E Missouri Street
Toyotalift , Inc
Development Standard Modification Request

Transmittal date: September 22, 2008

COMMENTS: Approved with conditions

1. Landscape Section recommends approval of DSMR request with the exception of the Slope to Depth Ratios per page 78 Stormwater, Detention, and Retention Manual.

If you have any questions about this transmittal, please call Joseph Linvilee or David Rivera, (520) 791-5608.
09/24/2008 ANDY VERA ENV SVCS REVIEW Approved
10/01/2008 DCORRAL1 COMMUNITY PLANNING REVIEW Approved DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Development Standard Modification Request (DSMR)

CASE NUMBER: CASE NAME: DATE SENT

DS08-45 266 E. Missouri St. 09/26/08

( ) Tentative Plat
( ) Development Plan
( ) Landscape Plan
( ) Revised Plan/Plat
( ) Board of Adjustment
(XXXX) Other - Site Plan

CROSS REFERENCE: N/A

AREA/NEIGHBORHOOD PLAN: General Plan

GATEWAY/SCENIC ROUTE: NO

COMMENTS DUE BY 09/22/08

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

(XXXX) Proposal Complies with Annexation or Rezoning Conditions
See Additional Comments Attached

This may be an opportunity to apply other water harvesting approaches.




REVIEWER: Rhowlett 791-4505 DATE: 09/26/08
10/06/2008 PATRICIA GEHLEN ZONING-DECISION LETTER WRITE DECISION LETTER Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
CITY OF TUCSON - DEVELOPMENT SERVICES

October 6, 2008

Philip Veneziano
Architects Studio Inc.
6011 East Grant Road
Tucson, Arizona 85712

Re: DSMR 08-45 - 266 East Missouri Street (T08CM01986)

Request: DS 10-01.4.3.1 - Modify the Development Standards to allow a basin to have continuous and uniform sideslopes that exceed 20% of the basin perimeter.

The Development Standard Modification Request (DSMR) listed above has been APPROVED by the CRDC committee with the following conditions:

1) Visual quality requirements remain in force except as modified by the DSMR,
2) The slope to depth ratios must meet page 78 of the Stormwater, Detention, and Retention manual.



PLEASE NOTE THAT A GENERAL NOTE MUST BE ADDED TO THE SITE PLAN WHICH STATES THE DSMR CASE NUMBER, DATE OF APPROVAL, MODIFICATIONS GRANTED, AND CONDITIONS IMPOSED. IN ADDITION, THE CASE NUMBER MUST BE ADDED TO EACH SHEET OF THE SITE PLAN, LANDSCAPE PLAN, AND NPPO PLAN, IN THE LOWER RIGHT CORNER NEAR THE TITLE BLOCK.


If you have any additional questions, please contact me at 837-4919.