Permit Number: DS08-43
Parcel: 13303283E

Review Status: Completed

Review Details: DEV STDS MODIFICATION REVIEW

Permit Number - DS08-43
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/04/2008 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
09/05/2008 RONALD BROWN ZONING HC SITE REVIEW Approved
09/08/2008 DAVE MANN FIRE REVIEW Approved
09/11/2008 MATT FLICK ENGINEERING REVIEW Approved DSD Engineering has no objection to approval of a DSMR to:

Dev. Std. 3-05.2.1.C.1, 3-05.6.0 (Fig. 1), 3-05.2.4.A.4 & 3-05.2.4.A.5: As it relates to parking areas between Lots 3/4 and 6/7.

Please note that this reviewer believes the detail for Lots 6/7, as referenced on Sheet 3 of 4, should be F/2, not E/2.
09/11/2008 JOHN BEALL COMMUNITY PLANNING REVIEW Approv-Cond DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Development Standard Modification Request (DSMR)

CASE NUMBER: CASE NAME: DATE SENT

DS08-43 1755 N. Houghton Rd. 09/11/08

( ) Tentative Plat
( ) Development Plan
( ) Landscape Plan
( ) Revised Plan/Plat
( ) Board of Adjustment
(XXXX) Other - Site Plan

CROSS REFERENCE: S06-236

AREA/NEIGHBORHOOD PLAN: Bear Canyon Neighborhood Plan

GATEWAY/SCENIC ROUTE: Houghton Road

COMMENTS DUE BY 09/11/08

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

(XXXX) Proposal Complies with Annexation or Rezoning Conditions (See additional comment)
( ) Proposal in Substantial Compliance with Plan Policies
(XXXX) See Additional Comments Below

Guest Parking to be clearly marked as such.

REVIEWER: R. Howlett 791-4505 DATE: 09/11/08
09/11/2008 JOSE ORTIZ TRAFFIC TRAFFIC Approved
09/12/2008 DAVID RIVERA ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

FROM: David Rivera
Principal Planner
DSD Zoning Review Section
PROJECT: DSMR-08-43
175 N Houghton Road
Wootton Property - Lots 1-7
Development Standard Modification Request

Transmittal date: September 12, 2008

COMMENTS: Approved with conditions

1. The DSMR application has been reviewed by zoning and can support one of the DSMR requests. While it appears that the specific DS sections are not presented correctly it is inferred that the request should be for a modification of the street cross sections figure one or two or both. This standard is DS 3-01 figure 1 and 2.

2. Zoning cannot support the 3-05.6.0 or 3-05.2.1.C.1. This request would require approval through the Board of Adjustments. The parking area next to lots 6 and 7 appears to meet the minimum requirements for on site maneuverability. The parking lot area next lot 3 and 4 does not meet the minimum requirements for onsite maneuverability and cannot be approved through a DSMR. An option to this request would be to move the parking spaces right up to the edge of the street pavement and make the parking area part of the street cross section rather than an easement.

If this proposed parking area is moved closer to the edge of the street pavement but kept in an easement the parking area is subject to landscape requirements. Also if the parking spaces are moved closer to the edge of the street pavement the sidewalk area must be relocated around the front of the parking spaces.

The five (5) parking space parking lot area must be redesigned to comply with development standards 3-05 and LUC section 3.3.7.2 table 3.3.7-I.



If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.
09/17/2008 ANDY VERA ENV SVCS REVIEW Approved
09/24/2008 PATRICIA GEHLEN ZONING-DECISION LETTER WRITE DECISION LETTER Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
CITY OF TUCSON - DEVELOPMENT SERVICES

September 24, 2008

Roberta Jo Chinea
Urban Engineering, Inc.
877 S. Alvernon Way, Suite 200
Tucson, Arizona 85711

Re: DSMR 08-43 - 1755 North Houghton Road (S06-235)

Request: DS 3-01 figures 1 and 2 - Modify the Development Standards to allow guest parking to back into a private street.

The Development Standard Modification Request (DSMR) listed above has been APPROVED FOR THE PARKING BETWEEN LOTS 6 AND 7 by the CRDC committee with the following conditions:

1) Guest parking to be clearly marked as such,
2) Detail for Lots 6/7 as reference on sheet 3 of 4 should be F/2, not E/2

The Development Standard Modification Request (DSMR) listed above has been DENIED FOR THE PARKING BETWEEN LOTS 3 AND 4.


PLEASE NOTE THAT A GENERAL NOTE MUST BE ADDED TO THE TENTATIVE PLAT WHICH STATES THE DSMR CASE NUMBER, DATE OF APPROVAL, MODIFICATIONS GRANTED, AND CONDITIONS IMPOSED. IN ADDITION, THE CASE NUMBER MUST BE ADDED TO EACH SHEET OF THE TENTATIVE PLAT, LANDSCAPE PLAN, AND NPPO PLAN, IN THE LOWER RIGHT CORNER NEAR THE TITLE BLOCK.


If you have any additional questions, please contact me at 837-4919.

Sincerely,


Patricia Gehlen
Zoning/CDRC Manager
Development Services Department

Attachments: 1
XC: file