Permit Review Detail
Review Status: Completed
Review Details: DEV STDS MODIFICATION REVIEW
Permit Number - DS08-43
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/04/2008 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 09/05/2008 | RONALD BROWN | ZONING HC SITE | REVIEW | Approved | |
| 09/08/2008 | DAVE MANN | FIRE | REVIEW | Approved | |
| 09/11/2008 | MATT FLICK | ENGINEERING | REVIEW | Approved | DSD Engineering has no objection to approval of a DSMR to: Dev. Std. 3-05.2.1.C.1, 3-05.6.0 (Fig. 1), 3-05.2.4.A.4 & 3-05.2.4.A.5: As it relates to parking areas between Lots 3/4 and 6/7. Please note that this reviewer believes the detail for Lots 6/7, as referenced on Sheet 3 of 4, should be F/2, not E/2. |
| 09/11/2008 | JOHN BEALL | COMMUNITY PLANNING | REVIEW | Approv-Cond | DEPARTMENT OF URBAN PLANNING & DESIGN Regarding SUBJECT: Development Standard Modification Request (DSMR) CASE NUMBER: CASE NAME: DATE SENT DS08-43 1755 N. Houghton Rd. 09/11/08 ( ) Tentative Plat ( ) Development Plan ( ) Landscape Plan ( ) Revised Plan/Plat ( ) Board of Adjustment (XXXX) Other - Site Plan CROSS REFERENCE: S06-236 AREA/NEIGHBORHOOD PLAN: Bear Canyon Neighborhood Plan GATEWAY/SCENIC ROUTE: Houghton Road COMMENTS DUE BY 09/11/08 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: (XXXX) Proposal Complies with Annexation or Rezoning Conditions (See additional comment) ( ) Proposal in Substantial Compliance with Plan Policies (XXXX) See Additional Comments Below Guest Parking to be clearly marked as such. REVIEWER: R. Howlett 791-4505 DATE: 09/11/08 |
| 09/11/2008 | JOSE ORTIZ | TRAFFIC | TRAFFIC | Approved | |
| 09/12/2008 | DAVID RIVERA | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL FROM: David Rivera Principal Planner DSD Zoning Review Section PROJECT: DSMR-08-43 175 N Houghton Road Wootton Property - Lots 1-7 Development Standard Modification Request Transmittal date: September 12, 2008 COMMENTS: Approved with conditions 1. The DSMR application has been reviewed by zoning and can support one of the DSMR requests. While it appears that the specific DS sections are not presented correctly it is inferred that the request should be for a modification of the street cross sections figure one or two or both. This standard is DS 3-01 figure 1 and 2. 2. Zoning cannot support the 3-05.6.0 or 3-05.2.1.C.1. This request would require approval through the Board of Adjustments. The parking area next to lots 6 and 7 appears to meet the minimum requirements for on site maneuverability. The parking lot area next lot 3 and 4 does not meet the minimum requirements for onsite maneuverability and cannot be approved through a DSMR. An option to this request would be to move the parking spaces right up to the edge of the street pavement and make the parking area part of the street cross section rather than an easement. If this proposed parking area is moved closer to the edge of the street pavement but kept in an easement the parking area is subject to landscape requirements. Also if the parking spaces are moved closer to the edge of the street pavement the sidewalk area must be relocated around the front of the parking spaces. The five (5) parking space parking lot area must be redesigned to comply with development standards 3-05 and LUC section 3.3.7.2 table 3.3.7-I. If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. |
| 09/17/2008 | ANDY VERA | ENV SVCS | REVIEW | Approved | |
| 09/24/2008 | PATRICIA GEHLEN | ZONING-DECISION LETTER | WRITE DECISION LETTER | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE CITY OF TUCSON - DEVELOPMENT SERVICES September 24, 2008 Roberta Jo Chinea Urban Engineering, Inc. 877 S. Alvernon Way, Suite 200 Tucson, Arizona 85711 Re: DSMR 08-43 - 1755 North Houghton Road (S06-235) Request: DS 3-01 figures 1 and 2 - Modify the Development Standards to allow guest parking to back into a private street. The Development Standard Modification Request (DSMR) listed above has been APPROVED FOR THE PARKING BETWEEN LOTS 6 AND 7 by the CRDC committee with the following conditions: 1) Guest parking to be clearly marked as such, 2) Detail for Lots 6/7 as reference on sheet 3 of 4 should be F/2, not E/2 The Development Standard Modification Request (DSMR) listed above has been DENIED FOR THE PARKING BETWEEN LOTS 3 AND 4. PLEASE NOTE THAT A GENERAL NOTE MUST BE ADDED TO THE TENTATIVE PLAT WHICH STATES THE DSMR CASE NUMBER, DATE OF APPROVAL, MODIFICATIONS GRANTED, AND CONDITIONS IMPOSED. IN ADDITION, THE CASE NUMBER MUST BE ADDED TO EACH SHEET OF THE TENTATIVE PLAT, LANDSCAPE PLAN, AND NPPO PLAN, IN THE LOWER RIGHT CORNER NEAR THE TITLE BLOCK. If you have any additional questions, please contact me at 837-4919. Sincerely, Patricia Gehlen Zoning/CDRC Manager Development Services Department Attachments: 1 XC: file Records Fax 318-3808 |