Parcel: 122173090

Review Status: Completed

Review Details: DEV STDS MODIFICATION REVIEW

Permit Number - DS08-40
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/22/2008 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
08/25/2008 DAVE MANN FIRE REVIEW Approved
08/26/2008 RONALD BROWN ZONING HC SITE REVIEW Approved
08/27/2008 DAVID RIVERA ZONING REVIEW Approved CDRC TRANSMITTAL

FROM: David Rivera
Principal Planner
DSD Zoning Review Section
PROJECT: DSMR-08-40
3139 E Bellevue St.
Bellevue Apartments
Development Standard Modification Request

Transmittal date: August 27, 2008

COMMENTS: Approved

If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.
08/27/2008 JOSE ORTIZ TRAFFIC TRAFFIC Approved
08/29/2008 MATT FLICK ENGINEERING REVIEW Approved DSD Engineering has no objection or adverse comment to approval of a DSMR for the following:

Dev. Std. 2-08.4.1: DSMR to allow the use of wedge curbing as separation of sidewalk from vehicular travel lane.

Dev. Std. 2-08.4.1.F: DSMR to allow for the placement of a sidewalk between a parking space and PAAL.




It should be noted that the FFEs presented on plan sheet A-1 do not conform with Dev. Std. 11-01.8.1.A. DSD Engineering would object to the approval of a DSMR for the excessive fill elevations.

Matt Flick, P.E.
Engineering Manager
Development Services Department
City of Tucson

Phone: (520) 837-4931
Fax: (520) 879-8010

Please visit our web site: www.ci.tucson.az.us/dsd
09/04/2008 ANDY VERA ENV SVCS REVIEW Approved
09/09/2008 ROGER HOWLETT COMMUNITY PLANNING REVIEW Approved DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Development Standard Modification Request (DSMR)

CASE NUMBER: CASE NAME: DATE SENT

DS08-40 3139 E. Bellevue St. 09/09/08

() Tentative Plat
() Development Plan
() Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
(XXXX) Other – Site Plan

CROSS REFERENCE: N/A

AREA/NEIGHBORHOOD PLAN: Grant-Alvernon Area Plan

GATEWAY/SCENIC ROUTE: No

COMMENTS DUE BY 08/29/08

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

(XXXX) Proposal Complies with Annexation or Rezoning Conditions
() Proposal in Substantial Compliance with Plan Policies
(XXXX) See Additional Comments Attached
() No Additional Comments - Complies With Planning Comments Submitted on:

Based on past experience, approval of these requests will result in guest parking taking place on sidewalk areas. Staff defers to traffic engineering and engineering.

REVIEWER: R. Howlett 791-4505 DATE: 09/09/08
09/10/2008 PATRICIA GEHLEN ZONING-DECISION LETTER WRITE DECISION LETTER Approved COMMUNITY DESIGN REVIEW COMMITTEE
CITY OF TUCSON - DEVELOPMENT SERVICES

September 10, 2008

Farzad Nakhai
Architect
905 North 10th Avenue
Tucson, Arizona 85705

Re: DSMR 08-40 - 3139 East Bellevue Street (T08CM01330)

Request: DS 2-08.4.1.F - Modify Development Standards to allow a pedestrian circulation system between a PAAL and a parking space,
DS 3-01 - figure 1 - Modify street cross section to allow a wedge curb to be adjacent to a sidewalk.

The Development Standard Modification Request (DSMR) listed above has been APPROVED by the CRDC committee without conditions.



PLEASE NOTE THAT A GENERAL NOTE MUST BE ADDED TO THE SITE PLAN WHICH STATES THE DSMR CASE NUMBER, DATE OF APPROVAL, MODIFICATIONS GRANTED, AND CONDITIONS IMPOSED. IN ADDITION, THE CASE NUMBER MUST BE ADDED TO EACH SHEET OF THE SITE PLAN, LANDSCAPE PLAN, AND NPPO PLAN, IN THE LOWER RIGHT CORNER NEAR THE TITLE BLOCK.


If you have any additional questions, please contact me at 837-4919.

Sincerely,


Patricia Gehlen
Zoning/CDRC Manager