Review Status: Completed
Review Details: DEV STDS MODIFICATION REVIEW
Permit Number - DS08-33
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/18/2008 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Passed | |
| 07/18/2008 | DAVE MANN | FIRE | REVIEW | Approved | |
| 07/21/2008 | DAVID RIVERA | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL FROM: David Rivera Principal Planner DSD Zoning Review Section PROJECT: DSMR-08-33 1801 W Valencia Road S08-043 The Shops At Midvale Development Standard Modification Request Transmittal date: July 21, 2008 COMMENTS: Approved with conditions 1. Approval by DSD Engineering and COT Traffic required. If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. |
| 07/21/2008 | RONALD BROWN | ZONING HC SITE | REVIEW | Approved | |
| 07/21/2008 | JOSE ORTIZ | TRAFFIC | TRAFFIC | Approved | |
| 07/24/2008 | MATT FLICK | ENGINEERING | REVIEW | Approv-Cond | DSD Engineering CONDITIONALLY APPROVES the DSMR to Dev. Std. 11-01.9.0.9.4 to allow the cut slope to extend to the property line with the following condition: Southbound shoulder/sidewalk area of Valley Indian Agency Road shall be graded at a maximum 2% cross-slope between the edge of pavement and top of basin/channel. DSD Engineering has NO OBJECTION OR ADVERSE COMMENT regarding the DSMRs to the following: Dev. Std. 3-01.3.2.C (drive spacing) Dev. Std. 2-03.2.4.L (minimum channel slope) Dev Std. 2-05.2.4.D (size of loading zone) Dev. Std. 9-06 (riparian habitat) |
| 07/24/2008 | INPL | CONSERVATION & SUSTAINABLE DEVELOPMENT | OCSD | Approved | see landscape review comments |
| 07/25/2008 | JOE LINVILLE | LANDSCAPE | REVIEW | Approv-Cond | The Landscape Section recommends approval the modifications, subject to incorporation of the following revisions into the Landscape and PRA Mitigation Plans: 1) Revise cross section on sheet 4 to show placement of plants on 4:1 slope and remove the reference to a 5' vegetative screen on sheet 4 of 5 of the PRA Mitigation Plan. 2) Revise the last sentence of item 4C on sheet 1 of the PRA Mitigation Plan. It may be necessary to provide irrigation for a longer term or to use the system during times of drought. 3) Revise the landscape plan to replace the Olneya tesota in the mitigation area with Prosopis velutina and to specify the native Desert Willow for the mitigation area, not the "Lois Adams". |
| 07/29/2008 | ANDY VERA | ENV SVCS | REVIEW | Approved | |
| 07/30/2008 | ROGER HOWLETT | COMMUNITY PLANNING | REVIEW | Approved | DEPARTMENT OF URBAN PLANNING & DESIGN Regarding SUBJECT: Development Standard Modification Request (DSMR) CASE NUMBER: CASE NAME: DATE SENT DS08-33 1801 W. Valencia Road 07/30/08 ( X ) Tentative Plat ( X ) Development Plan ( ) Landscape Plan ( ) Revised Plan/Plat ( ) Board of Adjustment ( ) Other - Site Plan CROSS REFERENCE: C9-07-20; S08-043 AREA/NEIGHBORHOOD PLAN: General Plan GATEWAY/SCENIC ROUTE: Gateway COMMENTS DUE BY July 24, 2008 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: ( X ) Proposal Complies with Annexation or Rezoning Conditions ( ) Proposal in Substantial Compliance with Plan Policies ( ) See Additional Comments Attached ( ) No Additional Comments - Complies With Planning Comments Submitted on: ( X ) No Resubmittal Required: ( ) Tentative Plat ( ) Development Plan ( ) Landscape Plan ( ) Other REVIEWER: JBeall 791-4505 DATE: 7/25/08 |
| 08/08/2008 | PATRICIA GEHLEN | ZONING-DECISION LETTER | WRITE DECISION LETTER | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE CITY OF TUCSON - DEVELOPMENT SERVICES August 8, 2008 John Holley, P.E. The WLB Group 4444 East Broadway Blvd. Tucson, Arizona 85711 Re: DSMR 08-33 - 1801 West Valencia Road (S08-043) Request: DS 3-01.6.3 Modify Development Standards to allow a less than 150 feet jog between streets. DS 2-03.2.4.L - Modify minimum slope for unlined channel as required by City of Tucson Manual for Drainage Design Section VIII 8.5.8. DS 9-06 - Modify Development Standards to allow a greater than 5% encroachment into the Protected Riparian Habitiat. DS 11-01.9.0.9.4 - Modify Development Standards to allow the cut slope to extend to the property line. The Development Standard Modification Request (DSMR) listed above has been APPROVED by the CRDC committee with the following conditions: 1) Southbound shoulder/sidewalk area of Valley Indian Agency Road shall be graded at a maximum 2% cross-slope between the edge of pavement and top of basin/channel. 2) Revise cross section on sheet 4 to show placement of plants on 4:1 slope and remove the reference to a 5' vegetative screen on sheet 4 of 5 of the PRA Mitigation Plan. 3) Revise the last sentence of item 4C on sheet 1 of the PRA Mitigation Plan. It may be necessary to provide irrigation for a longer term or to use the system during times of drought. 4) Revise the landscape plan to replace the Olneya tesota in the mitigation area with Prosopis velutina and to specify the native Desert Willow for the mitigation area, not the "Lois Adams". Request: LUC 3.4.5.3 - Reduce size of loading zone to 18'x10' The Land Use Code modification listed above has been DENIED by the CDRC committee because a Board of Adjustment variance is required for such a request. PLEASE NOTE THAT A GENERAL NOTE MUST BE ADDED TO THE TENTATIVE PLAT WHICH STATES THE DSMR CASE NUMBER, DATE OF APPROVAL, MODIFICATIONS GRANTED, AND CONDITIONS IMPOSED. IN ADDITION, THE CASE NUMBER MUST BE ADDED TO EACH SHEET OF THE TENTATIVE PLAT, LANDSCAPE PLAN, AND NPPO PLAN, IN THE LOWER RIGHT CORNER NEAR THE TITLE BLOCK. If you have any additional questions, please contact me at 837-4919. Sincerely, Patricia Gehlen Zoning/CDRC Manager Development Services Department Attachments: 1 XC: file Records Fax (520) 881-7492 |