Permit Review Detail
Review Status: Completed
Review Details: DEV STDS MODIFICATION REVIEW
Permit Number - DS08-30
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/02/2008 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 07/02/2008 | DAVID RIVERA | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL FROM: Terry Stevens Lead Planner DSD Zoning Review Section PROJECT: DSMR-DS08-30 11265 E. Fire Dancer Drive Development Standard Modification (DSMR) Request Transmittal date: 07/02/08 COMMENTS: Approved with conditions 1. Zoning has no issues with the requested DSMR. 2. Approval by Engineering and TDOT is required. If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961. |
| 07/03/2008 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 07/03/2008 | RONALD BROWN | ZONING HC SITE | REVIEW | Denied | 1. DENIED REMOVING SIDEWALKS, THAT WILL PUT PEDESTRIANS, WALKERS, IN THE ROAD. 2. APPROVE KNUCKLE CHANGE |
| 07/07/2008 | JOSE ORTIZ | TRAFFIC | TRAFFIC | Approved | |
| 07/09/2008 | PGEHLEN1 | COMMUNITY PLANNING | REVIEW | Approved | DEPARTMENT OF URBAN PLANNING & DESIGN Regarding SUBJECT: Development Standard Modification Request (DSMR) CASE NUMBER: CASE NAME: DATE SENT DS08-30 11265 E. Fire Dancer Drive 07/08/07 (X) Tentative Plat () Development Plan () Landscape Plan () Revised Plan/Plat () Board of Adjustment () Other CROSS REFERENCE: C9-06-15 & S07-173 NEIGHBORHOOD PLAN: H.A.M.P. SCENIC ROUTE: Yes COMMENTS DUE BY: 7/10/08 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: () No Annexation or Rezoning Conditions, Not an RCP - No Comment (XX) Proposal Complies with Annexation or Rezoning Conditions () RCP Proposal Complies with Plan Policies () See Additional Comments Attached () No Additional Comments - Complies With Planning Comments Submitted on: () Resubmittal Required: () Tentative Plat () Development Plan () Landscape Plan () Other REVIEWER: drcorral791-4505 DATE: 7/7/08 |
| 07/10/2008 | MATT FLICK | ENGINEERING | REVIEW | Approved | No objection or adverse comment to knuckle geometry and warped street section as per tentative plat. |
| 07/14/2008 | ANDY VERA | ENV SVCS | REVIEW | Approved | |
| 07/28/2008 | PATRICIA GEHLEN | ZONING-DECISION LETTER | WRITE DECISION LETTER | Approved | COMMUNITY DESIGN REVIEW COMMITTEE CITY OF TUCSON - DEVELOPMENT SERVICES July 28, 2008 Warren D. Thompson, PE Stantec Consulting, Inc. 201 North Bonita Avenue, Suite 101 Tucson, Arizona 85745 Re: DSMR 08-30 - 11265 East Fire Dancer Drive (S07-173) Request: DS 3-01.2.7.A - Modify Development Standards to allow the elimination of required sidewalk along east side of lots 39 and 58 in the proposed public ROW. The Development Standard Modification Request (DSMR) listed above has been DENIED by the CRDC committee. Request: DS 3-01.2.??? - Modify Development Standards to allow the geometrics of the street knuckles east of lots 21, 39, and 58 as shown on the tentative plat. The Development Standard Modification Request (DSMR) listed above has been APPROVED by the CRDC committee without condition. PLEASE NOTE THAT A GENERAL NOTE MUST BE ADDED TO THE TENTATIVE PLAT WHICH STATES THE DSMR CASE NUMBER, DATE OF APPROVAL, MODIFICATIONS GRANTED, AND CONDITIONS IMPOSED. IN ADDITION, THE CASE NUMBER MUST BE ADDED TO EACH SHEET OF THE TENTATIVE PLAT, LANDSCAPE PLAN, AND NPPO PLAN, IN THE LOWER RIGHT CORNER NEAR THE TITLE BLOCK. If you have any additional questions, please contact me at 837-4919. Sincerely, Patricia Gehlen Zoning/CDRC Manager Development Services Department Attachments: 1 XC: file Records Fax (520) 750-7470 |