Permit Number: DS08-18
Parcel: 13628005K

Review Status: Completed

Review Details: DEV STDS MODIFICATION REVIEW

Permit Number - DS08-18
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/15/2008 FRODRIG2 START PLANS SUBMITTED Completed
04/16/2008 DAVE MANN FIRE REVIEW Approved
04/17/2008 MATT FLICK ENGINEERING REVIEW Approv-Cond DS08-18

DSD Engineering CONDITIONALLY APPROVES the DSMR to Dev. Std. 2-05.2.4.L. The following condition is requested:

Sidewalk passing areas must be established at a reasonable distance not to exceed 200 feet and are to be a minimum of 6 feet in width. Transitions from other widths are to be made at a 3:1 ratio. Sidewalk to be constructed per SD 200 and SD 203. Existing sidewalk within the transition and passing area is to be saw cut to its full depth, removed and disposed as part of the sidewalk installation.
04/17/2008 JOSE ORTIZ TRAFFIC TRAFFIC Approved
04/18/2008 RONALD BROWN ZONING HC SITE REVIEW Denied 1. DOCUMENT "GOOD CONDITION" OF EXISTING CONCRETE SIDE WALK. SEND AN INSPECTOR TO CONFIRM
2. PROVIDE SPOT GRADES TO CONFIRM THAT SLOPES MEET COT DOT STANDARDS FOR ACCESSIBLE ROUTES. IF DOT SLOPE STANDARDS DO NOT EXIST, USE ADAAG SECTION 4.5.
04/22/2008 DAVID RIVERA ZONING REVIEW Approved CDRC TRANSMITTAL

FROM: Terry Stevens
Lead Planner
DSD Zoning Review Section

PROJECT: DSMR-DS08-18
4110 S. Pantano Rd.

Development Standard Modification (DSMR) Request

Transmittal date: 4/22/08

COMMENTS: Approved.

1. Zoning has no issues with the requested DSMR.


If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961.
04/24/2008 FRODRIG2 COMMUNITY PLANNING REVIEW Denied DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Development Standard Modification Request (DSMR)

CASE NUMBER: CASE NAME: DATE SENT

DS08-18 4110 S. Pantano Rd. 04/22/08

() Tentative Plat
(XXXX) Development Plan
() Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
() Other – Site Plan

CROSS REFERENCE: C9-07-03

AREA/NEIGHBORHOOD PLAN: Groves Neighborhood Plan/South Pantano Area Plan

GATEWAY/SCENIC ROUTE: N/A

COMMENTS DUE BY 04/22/08

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() Proposal Complies with Annexation or Rezoning Conditions
() Proposal in Substantial Compliance with Plan Policies
(XXXX) See Additional Comments Attached – Proposal Does not comply with Plan policy
() No Additional Comments - Complies With Planning Comments Submitted on:


REVIEWER: RHowlett791-4505 DATE: 04/22//08



The Circulation Element of the General Plan provides the following policy direction.

General Plan
Element 3: Circulation

Policy 5 Pedestrian Facilities: Plan and encourage the use of pedestrian facilities as a critical element of a safe and livable community to meet the transportation and recreational needs of the community.

5.1 Provide for the construction of accessible pedestrian facilities with all street construction and reconstruction; all private residential, commercial, and industrial development; and all public development in the urban area.

5.2 Develop a program for the installation of pedestrian facilities in already developed urban areas where they do not currently exist.

5.3 Design pedestrian facilities that are direct, safe, comfortable, aesthetically pleasing, and continuous.

5.4 Improve pedestrian visibility and safety and raise awareness of the benefits of walking.

Identify specific pedestrian mobility and accessibility challenges and develop measures for implementation of necessary improvements.

Given this site is located on a arterial street adjacent to a high school and a major park, a standard six foot sidewalk should be provided on both sides of Pantano Road to encourage and support pedestrian access to and from these facilities to the Groves neighborhood. Therefore, staff does not support the reduction in sidewalk width along Pantano Road.
04/25/2008 PATRICIA GEHLEN ZONING-DECISION LETTER WRITE DECISION LETTER Denied COMMUNITY DESIGN REVIEW COMMITTEE
CITY OF TUCSON - DEVELOPMENT SERVICES

April 25, 2008

Steve Oliverio
The WLB Group, Inc.
4444 East Broadway Blvd.
Tucson, Arizona 85711

Re: DSMR 08-18-4110 S. Pantano Road (D07-0053)

Request: DS 2-05.2.4.L - Modify Development Standards to allow existing four (4) foot sidewalk to remain in the right-of-way of Pantano Road instead of providing a six (6) foot sidewalk.

The Development Standard Modification Request (DSMR) listed above has been DENIED by the CRDC committee per the on-line comments.



PLEASE NOTE THAT A GENERAL NOTE MUST BE ADDED TO THE DEVELOPMENT PLAN WHICH STATES THE DSMR CASE NUMBER, DATE OF APPROVAL, MODIFICATIONS GRANTED, AND CONDITIONS IMPOSED. IN ADDITION, THE CASE NUMBER MUST BE ADDED TO EACH SHEET OF THE DEVELOPMENT PLAN, LANDSCAPE PLAN, AND NPPO PLAN, IN THE LOWER RIGHT CORNER NEAR THE TITLE BLOCK.


If you have any additional questions, please contact me at 837-4919.

Sincerely,


Patricia Gehlen
Zoning/CDRC Manager
Development Services Department

Attachments: 1
XC: file
Records

Fax (520) 881-7492
04/25/2008 ANDY VERA ENV SVCS REVIEW Approved No objections to this request as it pertains to ES requirements.