Permit Number: DS08-14
Parcel: 124170390

Address:
990 E 17TH ST

Review Status: Completed

Review Details: DEV STDS MODIFICATION REVIEW

Permit Number - DS08-14
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/21/2008 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
03/21/2008 DAVE MANN FIRE REVIEW Approved
03/21/2008 JOSE ORTIZ TRAFFIC TRAFFIC Approved
03/26/2008 DAVID RIVERA ZONING REVIEW Approv-Cond FROM: Steve Shields
Lead Planner
DSD Zoning Review Section

PROJECT: DSMR-DS08-14
990 E. 17th Street

Development Standard Modification (DSMR) Request

Transmittal date: March 26, 2008

COMMENTS: Conditionally Approved

1. Zoning conditionally approves the requested DSMR with the following conditions.

2. Zoning approves the DSMR request for modification of D.S. 3-05.2.2.B.1

3. Zoning denies the DSMR request for modification of D.S. 2-08.5.1.C Provide a sidewalk along the west end of the building that connects to the sidewalk system along the north side of the building. This sidewalk must be physically separated from any vehicular travel lane by means of curbing, grade separation, barriers, railings, or other means and be constructed per D.S. 2-08.5.1.C

4. This conditional approval of the DSMR does not approve the submitted site plan. A separate site plan review and approval is required.

If you have any questions about this transmittal, please call Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov.
03/27/2008 ANDY VERA ENV SVCS REVIEW Approved ES has no objections to this modification request as it has no adverse affect to ES requirements.
03/27/2008 MATT FLICK ENGINEERING REVIEW Approved DSD Engineering has no objection to approval of a DSMR for the following Development Standards:

DS 2-08.5.1.C - To allow an asphalt sidewalk in lieu of portland cement concrete.

DS 3-05.2.2.B.1 - To allow elimination of the 5' pedestrian refuge along the proposed addition.
04/02/2008 FRODRIG2 COMMUNITY PLANNING REVIEW Approved DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Development Standard Modification Request (DSMR)

CASE NUMBER: CASE NAME: DATE SENT

DS08-14 990 E. Seventeenth St. 04/01/08

() Tentative Plat
() Development Plan
() Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
(XXXX) Other – Site Plan

CROSS REFERENCE: N/A

NEIGHBORHOOD PLAN: Greater South Park Plan

GATEWAY/SCENIC ROUTE:

COMMENTS DUE BY 03/27/08

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() Proposal Complies with Annexation or Rezoning Conditions
(XXXX) Proposal in Substantial Compliance with Plan Policies
() See Additional Comments Attached
() No Additional Comments - Complies With Planning Comments Submitted on:

() Resubmittal Required:
() Tentative Plat
() Development Plan
() Landscape Plan
() Other


REVIEWER: RHowlett791-4505 DATE: 04/01/08/07
04/04/2008 PATRICIA GEHLEN ZONING-DECISION LETTER WRITE DECISION LETTER Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
CITY OF TUCSON - DEVELOPMENT SERVICES

April 4, 2008

Dinkar Gangwal
Alpha Engineering, Inc.
117 North 6th Avenue
Tucson, Arizona 85701

Re: DSMR 08-14- 990 East Seventeenth Street (T08OT00640)

Request: DS 3-05.2.2.B.1 - Modify Development Standards to eliminate a portion of the pedestrian circulation system along the south side of the proposed building enclosure.

The Development Standard Modification Request (DSMR) listed above has been APPROVED by the CRDC committee without condition.

Request: DS 2-08.5.1.C - Modify Development Standards to allow a portion of the pedestrian circulation system to be asphalt instead of concrete.

The Development Standard Modification Request (DSMR) listed above has been DENIED by the CDRC committee.

PLEASE NOTE THAT A GENERAL NOTE MUST BE ADDED TO THE SITE PLAN WHICH STATES THE DSMR CASE NUMBER, DATE OF APPROVAL, MODIFICATIONS GRANTED, AND CONDITIONS IMPOSED. IN ADDITION, THE CASE NUMBER MUST BE ADDED TO EACH SHEET OF THE SITE PLAN, LANDSCAPE PLAN, AND NPPO PLAN, IN THE LOWER RIGHT CORNER NEAR THE TITLE BLOCK.


If you have any additional questions, please contact me at 837-4919.

Sincerely,


Patricia Gehlen
Zoning/CDRC Manager
Development Services Department

Attachments: 1
XC: file
Records

Fax (520) 622-8334