Permit Number: DS08-13
Parcel: 13408280E

Address:
8525 E 22ND ST

Review Status: Completed

Review Details: DEV STDS MODIFICATION REVIEW

Permit Number - DS08-13
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/18/2008 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
03/19/2008 MATT FLICK ENGINEERING REVIEW Approved DSD Engineering has no objection to approval of a DSMR to Dev. Std. 3-01.6.2.C.2 (& Figure 23) for a hammerhead with an angle of less than 90 degrees (approx. 68 degrees).
03/20/2008 DAVE MANN FIRE REVIEW Approved
03/20/2008 JOSE ORTIZ TRAFFIC TRAFFIC Approved
03/20/2008 DAVID RIVERA ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

FROM: Terry Stevens
Lead Planner
DSD Zoning Review Section

PROJECT: DSMR-DS08-13
8525 E. 22nd St.

Development Standard Modification (DSMR) Request

Transmittal date:

COMMENTS: Approved with conditions

1. Zoning has no issues with the requested DSMR.

2. Approval by Engineering is required.

If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961.
03/26/2008 ANDY VERA ENV SVCS REVIEW Approved
03/28/2008 CDRC1 COMMUNITY PLANNING REVIEW Passed DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Development Standard Modification Request (DSMR)

CASE NUMBER: CASE NAME: DATE SENT

DS08-13 8525 E. 22nd Street

(X) Tentative Plat
() Development Plan
() Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
() Other

CROSS REFERENCE: S06-221 (RCP Subdivision)

NEIGHBORHOOD PLAN: Pantano East Area Plan

GATEWAY/SCENIC ROUTE: NO

COMMENTS DUE BY 3/25/08

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() Proposal Complies with Annexation or Rezoning Conditions
(X) Proposal in Substantial Compliance with Plan Policies
() See Additional Comments Attached
() No Additional Comments - Complies With Planning Comments Submitted on:










REVIEWER: msp 791-4505 DATE: 3/25/08
04/04/2008 PATRICIA GEHLEN ZONING-DECISION LETTER WRITE DECISION LETTER Approved COMMUNITY DESIGN REVIEW COMMITTEE
CITY OF TUCSON - DEVELOPMENT SERVICES

April 4, 2008

Dinkar Gangwal
Alpha Engineering, Inc.
117 North 6th Avenue
Tucson, Arizona 85701

Re: DSMR 08-13- 8525 East 22nd Street (S06-221)

Request: DS 3-01.6.2.C.2 and figure 23 - Modify Development Standards to allow a hammerhead with an angle of less than 90 degrees (approximately 68 degrees).

The Development Standard Modification Request (DSMR) listed above has been APPROVED by the CRDC committee without condition.



PLEASE NOTE THAT A GENERAL NOTE MUST BE ADDED TO THE TENTATIVE PLAT WHICH STATES THE DSMR CASE NUMBER, DATE OF APPROVAL, MODIFICATIONS GRANTED, AND CONDITIONS IMPOSED. IN ADDITION, THE CASE NUMBER MUST BE ADDED TO EACH SHEET OF THE TENTATIVE PLAT, LANDSCAPE PLAN, AND NPPO PLAN, IN THE LOWER RIGHT CORNER NEAR THE TITLE BLOCK.


If you have any additional questions, please contact me at 837-4919.