Permit Review Detail
Review Status: Completed
Review Details: DEV STDS MODIFICATION REVIEW
Permit Number - DS08-07
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/28/2008 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 02/29/2008 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 02/29/2008 | MATT FLICK | ENGINEERING | REVIEW | Approved | DSD Engineering has no objection or adverse comment to the issuance of a DSMR to Dev. Std. 2-08.4.1.B to omit the sidewalk between the expanded parking area at the SW corner of the site and the existing building along the southern property line. |
| 03/03/2008 | JOSE ORTIZ | TRAFFIC | TRAFFIC | Approved | |
| 03/06/2008 | ANDY VERA | ENV SVCS | REVIEW | Approv-Cond | 1. In regards to the modification request of DS 2-08.4.1.B ES has no objections to this request. However, upon further review, this site plan does not mention or show provisions for on site refuse and recycling collection services. Where the existing dumpster is positioned the plan does not allow adequate egress from the dumpster due to the proposed covered walkway and patio obstructing this pathway. Please clarify. If you have any questions you may contact Andy Vera at (520) 791-5543 ext 1212 or e-mail: Andy.Vera@tucsonaz.gov |
| 03/06/2008 | DAVID RIVERA | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL FROM: Terry Stevens Lead Planner DSD Zoning Review Section PROJECT: DSMR-DS08-07 3830 E. Bellevue Development Standard Modification (DSMR) Request Transmittal date: COMMENTS: Approved with conditions 1. Zoning approves conditionally the elimination of the sidewalk along the west side of the south building 2. The parking area proposed be limited to employee parking only. If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961. |
| 03/10/2008 | FRODRIG2 | COMMUNITY PLANNING | REVIEW | Approved | DEPARTMENT OF URBAN PLANNING & DESIGN Regarding SUBJECT: Development Standard Modification Request (DSMR) CASE NUMBER: CASE NAME: DATE SENT DS08-07 3830 E. Belleveu 03/06/08 () Tentative Plat () Development Plan () Landscape Plan () Revised Plan/Plat () Board of Adjustment (XXXX) Other – Site Plan CROSS REFERENCE: NEIGHBORHOOD PLAN: Grant-Alvernon GATEWAY/SCENIC ROUTE: COMMENTS DUE BY March. 6, 2008 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: () Proposal Complies with Annexation or Rezoning Conditions () Proposal in Substantial Compliance with Plan Policies (XXXX) See Additional Comments Attached () No Additional Comments - Complies With Planning Comments Submitted on: () Resubmittal Required: () Tentative Plat () Development Plan () Landscape Plan () Other REVIEWER: drcorral 791-4505 DATE: 03/4/08 The applicant is requesting relief from Development Standard 2-08.4.1 that requires a sidewalk be provided adjacent to any parking space accessed by a PAAL. Policies in the Grant-Alvernon Area Plan are as follows: A. GENERAL LAND USE POLICIES: Intent Statement: The General Land Use Policies are intended to provide criteria for determining where development is appropriate. They support development that serves to enhance the character and quality of Grant-Alvernon neighborhoods. These policies are meant to be used in conjunction with the General Design Guidelines. Policy 5. Utilize Defensible Space Guidelines in design development (see General Design Guidelines). E. DEFENSIBLE SPACE Design Guideline 1. Utilize curbs and sidewalks to define public, semi- public, and private areas. Based on the design of the site, the applicant has provided sufficient justification for this development standard modification request; thus, the plans support relief from Development Standard 2-08.4.1.B. |
| 03/13/2008 | PATRICIA GEHLEN | ZONING-DECISION LETTER | WRITE DECISION LETTER | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE CITY OF TUCSON - DEVELOPMENT SERVICES March 13, 2008 David Johns Omni Architecture Inc. 2910 North Swan Road #105 Tucson, Arizona 85712 Re: DSMR 08- 07- 3830 East Bellevue (no activity number found) Request: DS 2-08.4.1.C - Modify Development Standards to eliminate the portion of the on-site pedestrian circulation system along the west side of the southern most existing building. The Development Standard Modification Request (DSMR) listed above has been APPROVED by the CRDC committee with the following conditions: 1) Although not related to this DSMR, ESD has concerns about the dumpster location. Please see Permits Plus for detailed list of concerns. 2) The parking area proposed be limited to employee parking only. PLEASE NOTE THAT A GENERAL NOTE MUST BE ADDED TO THE SITE PLAN WHICH STATES THE DSMR CASE NUMBER, DATE OF APPROVAL, MODIFICATIONS GRANTED, AND CONDITIONS IMPOSED. IN ADDITION, THE CASE NUMBER MUST BE ADDED TO EACH SHEET OF THE SITE PLAN, LANDSCAPE PLAN, AND NPPO PLAN, IN THE LOWER RIGHT CORNER NEAR THE TITLE BLOCK. If you have any additional questions, please contact me at 837-4919. Sincerely, Patricia Gehlen Zoning/CDRC Manager Development Services Department Attachments: 1 XC: file Records Fax 326-0528 |