Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: DS08-05
Parcel: 106030550

Address:
3232 N STONE AV

Review Status: Completed

Review Details: DEV STDS MODIFICATION REVIEW

Permit Number - DS08-05
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/20/2008 FRODRIG2 START PLANS SUBMITTED Completed
02/25/2008 MATT FLICK ENGINEERING REVIEW Approv-Cond DSD Engineering CONDITIONALLY APPROVES the request for a 3' sidewalk along the southern property line if there are no walls to be constructed adjacent to the sidewalk. If a wall is to be constructed, the minimum sidewalk width shall remain 4'.
02/26/2008 DAVE MANN FIRE REVIEW Approved
02/26/2008 JOSE ORTIZ TRAFFIC TRAFFIC Approved
02/27/2008 DAVID RIVERA ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

FROM: Terry Stevens
Lead Planner
DSD Zoning Review Section

PROJECT: DSMR-DS08-05
3232 N. Stone Ave.

Development Standard Modification (DSMR) Request

Transmittal date:

COMMENTS: Approved with conditions

1. Zoning has no issues with the requested DSMR.

2. Approval by Engineering is required.

If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961.
02/29/2008 FRODRIG2 COMMUNITY PLANNING REVIEW Approv-Cond DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Development Standard Modification Request (DSMR)

CASE NUMBER: CASE NAME: DATE SENT

DS08-05 3232 N. Stone Avenue 02/28/08

() Tentative Plat
() Development Plan
() Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
(XX) Other – Site Plan

CROSS REFERENCE:

NEIGHBORHOOD PLAN: Cragin-Keeling

GATEWAY/SCENIC ROUTE:

COMMENTS DUE BY 02/27/08

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() Proposal Complies with Annexation or Rezoning Conditions
() Proposal in Substantial Compliance with Plan Policies
(XXXX) See Additional Comments Attached

() No Additional Comments - Complies With Planning Comments Submitted on:

() Resubmittal Required:
() Tentative Plat
() Development Plan
() Landscape Plan
() DSMR Denied



REVIEWER: drcorral 791-4505 DATE: 02/28/08

The Cragin-Keeling Area Plan provides policy direction for this request.

The applicant proposes to install a three-foot-wide sidewalk instead of the required four-foot-wide sidewalk along the southern border of the site adjacent to an alley. Per Cragin-Keeling Area Plan policy, the applicant is required to provide safe pedestrian refuge areas and sidewalks, for all new developments. Constricting pedestrians between an alley and parked cars seems to be counter to what the Plan calls for. There appear to be other options to the overall site design, such as the a six foot no build area along the north side of the project, which seems to be a logical place to locate a sidewalk area.

TRANSPORTATION
Intent Statement: These policies are intended to ensure the integration of new development and road improvements, ensure the safety of neighborhood residents, reduce traffic flow by discouraging non-arterial through traffic, and to ensure that new development is responsive to the use of alternative modes of transportation.
10. Provide safe and efficient pedestrian access throughout the Cragin-Keeling area.
a. Provide pedestrian refuge areas with street improvements and within new developments.
b. Require sidewalks in all new private and public development per the adopted sidewalk policy.
02/29/2008 ANDY VERA ENV SVCS REVIEW Approved ES has no objections to this request. Curbside APC refuse and recycle collection service will be adequate for this small office development.
03/04/2008 PATRICIA GEHLEN ZONING-DECISION LETTER WRITE DECISION LETTER Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
CITY OF TUCSON - DEVELOPMENT SERVICES

March 4, 2008

Martio L. Harris
Tio's Master Cutz
3100 North Stone Avenue, #A126
Tucson, Arizona 85705

Re: DSMR 08- 05- 3232 North Stone Avenue (T07CM01348)

Request: DS 2-08.5.1.A - Modify Development Standards to allow the portion of the on-site pedestrian circulation system along the south property line to be three (3) feet in width.

The Development Standard Modification Request (DSMR) listed above has been APPROVED by the CRDC committee with the following conditions:

1) No walls may be constructed adjacent to the three (3) foot sidewalk,
2) Relocate the sidewalk to the north side of the property (in the no-build easement) if possible.


PLEASE NOTE THAT A GENERAL NOTE MUST BE ADDED TO THE SITE PLAN WHICH STATES THE DSMR CASE NUMBER, DATE OF APPROVAL, MODIFICATIONS GRANTED, AND CONDITIONS IMPOSED. IN ADDITION, THE CASE NUMBER MUST BE ADDED TO EACH SHEET OF THE SITE PLAN, LANDSCAPE PLAN, AND NPPO PLAN, IN THE LOWER RIGHT CORNER NEAR THE TITLE BLOCK.


If you have any additional questions, please contact me at 837-4919.

Sincerely,


Patricia Gehlen
Zoning/CDRC Manager
Development Services Department

Attachments: 1
XC: file
Records

Fax 798-3399