Permit Number: DS07-50
Parcel: 12510006C

Review Status: Completed

Review Details: DEV STDS MODIFICATION REVIEW

Permit Number - DS07-50
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/21/2007 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
11/21/2007 DAVID RIVERA ZONING REVIEW Approved
11/23/2007 JIM EGAN FIRE REVIEW Approved
11/23/2007 MATT FLICK ENGINEERING REVIEW Approved DSD Engineering has no objection or adverse comment to approval of a DSMR to Dev. Std. 2-08.3.1 to allow the use of pedestrian paths within the rights-of-way toward on-site pedestrian connection/circulation.
11/26/2007 JOSE ORTIZ TRAFFIC TRAFFIC Approved Traffic Engineering has no objections to the requested DSMR to Development Standard 2-08.3.1.
11/30/2007 FRODRIG2 COMMUNITY PLANNING REVIEW Approv-Cond DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Development Standards Modification Request (DSMR)

CASE NUMBER: CASE NAME: DATE SENT

DS07-50 3601 E. Broadway Boulevard 11/28/07

() Tentative Plat
(XXXX) Development Plan
() Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
() Other – Site Plan

CROSS REFERENCE: D07- 0029 (El Con)

NEIGHBORHOOD PLAN: Alvernon Broadway


GATEWAY/SCENIC ROUTE: Gateway

COMMENTS DUE BY: 11/29/07


SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

( ) No Annexation or Rezoning Conditions, Not an RCP - No Comment
() Proposal Complies with Annexation or Rezoning Conditions
() RCP Proposal Complies With Plan Policies
( X ) See Additional Comments Attached
( ) No Additional Comments - Complies With Planning Comments Submitted on:
( X ) No Resubmittal Required:
() Tentative Plat
() Development Plan
() Landscape Plan
() Other

REVIEWER: JBeall 791-4505 DATE: November 28, 2007

Comments


The Development Standard Modification Review for PAD 6 which proposes to follow the same pedestrian access path as PAD 7 can be approved with the following condition:

That the pedestrian access and crossing as shown on the Development Plan which connects Claim Jumper - PAD 7 to the parking lot to the north of its site be constructed at the same time as the development and construction of PAD 6 as identified on the Development Plan, Sheet SP1.2.
12/03/2007 ANDY VERA ENV SVCS REVIEW Approved
12/07/2007 PATRICIA GEHLEN ZONING-DECISION LETTER WRITE DECISION LETTER Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
CITY OF TUCSON - DEVELOPMENT SERVICES



December 6, 2007

Ghazal Farhang
Novak Environmental Inc.
4574 North First Avenue
Tucson, Arizona 85718

Re: DSMR 07- 50- 3601 East Broadway Boulevard (D07-0029)

Request: DS 2-08.3.1 - Modify pedestrian circulation system to share access to Broadway and Dodge Boulevards with other Pads in the development.

The Development Standard Modification Request (DSMR) listed above has been APPROVED by the CRDC committee with the following conditions:

1) The pedestrian access and crossing as shown on the development plan which connects Pad 7 to the parking lot to the north be constructed at the same time as this development as shown on sheet SP1.2.


PLEASE NOTE THAT A GENERAL NOTE MUST BE ADDED TO THE DEVELOPMENT PLAN WHICH STATES THE DSMR CASE NUMBER, DATE OF APPROVAL, MODIFICATIONS GRANTED, AND CONDITIONS IMPOSED. IN ADDITION, THE CASE NUMBER MUST BE ADDED TO EACH SHEET OF THE DEVELOPMENT PLAN, LANDSCAPE PLAN, AND NPPO PLAN, IN THE LOWER RIGHT CORNER NEAR THE TITLE BLOCK.

If you have any additional questions, please contact me at 837-4919.

Sincerely,


Patricia Gehlen
Zoning/CDRC Manager
Development Services Department

Attachments: 1
XC: file