Permit Number: DS07-48
Parcel: 12215312A

Review Status: Completed

Review Details: DEV STDS MODIFICATION REVIEW

Permit Number - DS07-48
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/15/2007 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
11/16/2007 JIM EGAN FIRE REVIEW Approved
11/16/2007 MATT FLICK ENGINEERING REVIEW Approved DSD Engineering has no objection or adverse comment to location of the walls within the future right-of-way and future SVT (DS 3-01.5.1.B.2) along Country Club Road.

Matt Flick, P.E.
Engineering Manager
Development Services Department
City of Tucson

Phone: (520) 837-4931
Fax: (520) 879-8010

Please visit our web site: www.ci.tucson.az.us/dsd
11/20/2007 JOSE ORTIZ TRAFFIC TRAFFIC Approved
11/21/2007 DAVID RIVERA ZONING REVIEW Approved
11/26/2007 FRODRIG2 COMMUNITY PLANNING REVIEW Approved DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Development Standards Modification Request (DSMR)

CASE NUMBER: CASE NAME: DATE SENT

DS07-48 1900 N. Country Club 11/26/07

() Tentative Plat
(XXXX) Development Plan
() Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
() Other – Site Plan

CROSS REFERENCE:

NEIGHBORHOOD PLAN: Grant-Alvernon Area Plan


GATEWAY/SCENIC ROUTE:

COMMENTS DUE BY: 11/23/07


SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

(XXXX) No Annexation or Rezoning Conditions, Not an RCP - No Comment
() Proposal Complies with Annexation or Rezoning Conditions
() RCP Proposal Complies With Plan Policies
() See Additional Comments Attached
( ) No Additional Comments - Complies With Planning Comments Submitted on:
( ) No Resubmittal Required:
() Tentative Plat
() Development Plan
() Landscape Plan
() Other

REVIEWER: drcorral 791-4505 DATE: November 26, 2007
11/27/2007 ANDY VERA ENV SVCS REVIEW Approv-Cond 1. ES has no objections to the request for modifcations to DS 3-01.5.1.B.2

However, in reviewing the site plan the current positioning of the refuse/recycle enclosure is in conflict with the adjacent parking. Manueverability is not adequate within the required minimum 14 ft x 40 ft clear approach to enclosure area. Recommend positioning enclosure at a 30 degree angle or move back 5 ft to allow adequate maneuverability and approach to enclosure.

If you have any questions you may contact Andy Vera at (520) 791-5543 ext 1212 or e-mail: Andy.Vera@tucsonaz.gov
11/27/2007 PATRICIA GEHLEN ZONING-DECISION LETTER WRITE DECISION LETTER Approved COMMUNITY DESIGN REVIEW COMMITTEE
CITY OF TUCSON - DEVELOPMENT SERVICES

November 27, 2007

Chris Evans
J. Chris Evans, Architect
3220 East Terra Alta #9
Tucson, Arizona 85716

Re: DSMR 07- 48- 1900 N. Country Club Road (T07CM02684)

Request: DS 3-01.5.1.B.2 - Place wall in future right-of-way and future sight visibility triangle.

The Development Standard Modification Request (DSMR) listed above have been APPROVED by the CRDC committee without condition.





PLEASE NOTE THAT A GENERAL NOTE MUST BE ADDED TO THE SITE PLAN WHICH STATES THE DSMR CASE NUMBER, DATE OF APPROVAL, MODIFICATIONS GRANTED, AND CONDITIONS IMPOSED. IN ADDITION, THE CASE NUMBER MUST BE ADDED TO EACH SHEET OF THE SITE PLAN, LANDSCAPE PLAN, AND NPPO PLAN, IN THE LOWER RIGHT CORNER NEAR THE TITLE BLOCK.

If you have any additional questions, please contact me at 837-4919.

Sincerely,


Patricia Gehlen
Zoning/CDRC Manager
Development Services Department

Attachments: 1
XC: file
Records

Fax (520) 319-8835 (call first)