Review Details: DEV STDS MODIFICATION REVIEW
Permit Number - DS07-25
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/28/2007 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 07/02/2007 | JIM EGAN | FIRE | REVIEW | Approved | |
| 07/02/2007 | JOSE ORTIZ | TRAFFIC | TRAFFIC | Approved | |
| 07/03/2007 | MATT FLICK | ENGINEERING | REVIEW | Approv-Cond | DSD Engineering conditionally approves the request for the DSMR with the condition that the DSMR to Dev. Std. 2-02.2.1.A.32 is not granted. There is no objection to placement of the dumpster as shown. DSD Engineering has no objection to approval of a DSMR to Dev. Std. 6-01.2.2.A and 6-01.4.1.I to allow access to the dumpster location from Utah Street. DSD Engineering objects to granting a DSMR to Dev. Std. 2-02.2.1.A.32: "32. Refuse container location, size, and access thereto fully dimensioned." Since DSD Engineering believes it is necessary to show the refuse container location, size, and access thereto. Given that the applicant has shown much of this information on Sheet A0.02 (submitted with the DSMR application) and references further information (Detail 11) on Sheet A0.0, DSD Engineering believes the applicant has mistakenly included this development standard in the application. |
| 07/10/2007 | DAVID RIVERA | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL FROM: David Rivera Principal Planner DSD Zoning Review Section PROJECT: DSMR-07-25 407 W Utah St. Dorey Apartments - Multi-Family development Development Standard Modification Request - Modification to Development Standards - 2-02.2.1.A.32, 6-01.A.1.I, 6-01.2.2.A Transmittal date: July 10, 2007 COMMENTS: Approved with conditions Zoning and Landscape staff reviewers conditionally approve the proposed DSMR pending approval by the Engineering, Traffic, Environmental Services departments. Zoning and Landscape reviewers do not see a need for a Board of Adjustment variance due to the location of the Dumpster and enclosure location. The width of the ten (10) foot landscape buffer may not be reduced due to the location of the enclosure. If the DSMR is approved for the width of the driveway entrance the length of the street landscape buffer meets code. Add the following to verify that the enclosure does not reduce the required width of the ten-foot landscape buffer. 1. Add a dimension from the nearest corner of the enclosure to the property line. The enclosure must measure a full ten feet. If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. |
| 07/11/2007 | ANDY VERA | ENV SVCS | REVIEW | Approved | 1. Access and approach will work as shown. 2. Refuse enclosure requires a minimum of two bollards at the rear and one bollard on each side within the enclsoure service/dumpster with a 10ft x 10ft inside clear area between the bollards. |
| 07/17/2007 | CDRC1 | COMMUNITY PLANNING | REVIEW | Approved | DEPARTMENT OF URBAN PLANNING & DESIGN COMMENTS Regarding SUBJECT: Development Standard Modification Request (DSMR) CASE NUMBER: CASE NAME: DATE SENT DS04-25 407 W. Utah ( ) Tentative Plat ( ) Development Plan ( ) Landscape Plan ( ) Revised Plan/Plat ( ) Board of Adjustment (XXXX) Other - Site Plan CROSS REFERENCE: NEIGHBORHOOD PLAN: 12th Avenue and Valencia GATEWAY/SCENIC ROUTE: COMMENTS DUE BY: 07/06/07 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: ( ) No Annexation or Rezoning Conditions, Not an RCP - No Comment (XXXX) Proposal Complies with Annexation or Rezoning Conditions ( ) RCP Proposal Complies with Plan Policies ( ) See Additional Comments Attached ( ) No Additional Comments - Complies With Planning Comments Submitted on: ( ) Resubmittal Required: ( ) Tentative Plat ( ) Development Plan ( ) Landscape Plan ( ) Other REVIEWER: drcorral 791-4505 DATE: 7/6/07 |
| 07/17/2007 | PATRICIA GEHLEN | ZONING-DECISION LETTER | WRITE DECISION LETTER | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE CITY OF TUCSON - DEVELOPMENT SERVICES July 17, 2007 Chris Anderson/Eric V. Fike The Architecture Company 2625 North Silverbell Road Tucson, Arizona 85745 Re: DSMR 07- 25- 407 West Utah (No site plan activity number could be found) Request: DS 6-01.4.1.I and 2.2.A- Modify location of dumpster to allow access and maneuvering in the right of way of Utah Street. The Development Standard Modification Request (DSMR) listed above has been APPROVED by the CRDC committee with the following conditions: 1) Add a dimension from the nearest corner of the enclosure to the property line. The enclosure may not encroach into the l0 foot landscape buffer, 2) Refuse enclosures require a minimum of two bollards at the rear and one bollard on each side within the enclosure with a 10 foot x 10 foot inside clear area between the bollards. PLEASE NOTE THAT A GENERAL NOTE MUST BE ADDED TO THE SITE PLAN WHICH STATES THE DSMR CASE NUMBER, DATE OF APPROVAL, MODIFICATIONS GRANTED, AND CONDITIONS IMPOSED. IN ADDITION, THE CASE NUMBER MUST BE ADDED TO EACH SHEET OF THE SITE PLAN, LANDSCAPE PLAN, AND NPPO PLAN, IN THE LOWER RIGHT CORNER NEAR THE TITLE BLOCK. If you have any additional questions, please contact me at 837-4919. Sincerely, Patricia Gehlen Zoning/CDRC Manager Development Services Department Attachments: 1 XC: file Records Fax (520) 620-6097 |