Permit Review Detail
Review Status: Completed
Review Details: DEV STDS MODIFICATION REVIEW
Permit Number - DS07-21
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/22/2009 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 09/23/2009 | RONALD BROWN | ZONING HC | REVIEW | Approved | |
| 09/24/2009 | DAVID RIVERA | ZONING | REVIEW | Approved | CDRC TRANSMITTAL FROM: David Rivera Principal Planner DSD Zoning Review Section PROJECT: DSMR-07-21 209 E Limberlost Drive Callecita Villas Condos Development Standard Modification Request Transmittal date: September 24, 2009 COMMENTS: Approved with conditions 1. DSMR for DS 3-01.2.2.A: After discussions with Traffic Engineering staff it has been determined that the ADT can be reduced to under 140 ADT based on alternate entrances and likely traffic patterns for the subdivision to the north. DMSR request approved. 2. DSMR for 3-05.2.2.B.1: The development standard modification will not reduce the sidewalk width less than four feet. This width is sufficient to comply with the minimum ADA requirements and is requested for three small section of the sidewalk area. DSMR request approved. 3. DSMR for DS 3-01.3.3.A: Zoning approves the request with the conditions that DSD engineering and TDOT supports and approves the DSMR request. DSMR request approved conditionally. If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. |
| 09/24/2009 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 09/25/2009 | MATT FLICK | ENGINEERING | REVIEW | Approved | PDSD Engineering has no objection to approval of a DSMR whereby Ponderosa Street ADT is less than 140. PDSD Engineering disagrees with the methodology used. PDSD Engineering has no objection to approval of a DSMR to allow 4' wide sidewalks at the locations shown. PDSD Engineering disagrees with the reasoning presented. PDSD Engineering has no objection to approval iof a DSMR to allow the 4' sidewalk along Limberlost Drive to remain as it is in good condition and there are no long stretches where passing is not possible. Whether Limberlost is classified per the MS&RP seems immaterial. |
| 09/28/2009 | MPADILL1 | COMMUNITY PLANNING | REVIEW | Completed | DEPARTMENT OF PLANNING & DEVELOPMENT SERVICES COMMENTS Regarding SUBJECT: Development Standard Modification Request (DSMR) CASE NUMBER: CASE NAME: DATE SENT DS07-21 Callecita Villas Condos ( ) Tentative Plat ( ) Development Plan ( ) Landscape Plan ( ) Revised Plan/Plat ( ) Board of Adjustment (X) Other - Site Plan CROSS REFERENCE: DS06-20 NEIGHBORHOOD PLAN: North Stone Neighborhood Plan GATEWAY/SCENIC ROUTE: No COMMENTS DUE BY: 09/29/09 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: ( ) No Annexation or Rezoning Conditions, Not an RCP - No Comment (X) Proposal in Substantial Compliance with Plan Policies ( ) RCP Proposal Complies with Plan Policies ( ) See Additional Comments Attached ( ) No Additional Comments - Complies With Planning Comments Submitted on: ( ) Resubmittal Required: ( ) Tentative Plat ( ) Development Plan ( ) Landscape Plan ( ) Other REVIEWER: msp 791-5505 DATE: 09/25/09 |
| 10/02/2009 | ANDY VERA | ENV SVCS | REVIEW | Approved | |
| 10/05/2009 | JOSE ORTIZ | TRAFFIC | TRAFFIC | Approved | |
| 10/09/2009 | PATRICIA GEHLEN | ZONING-DECISION LETTER | WRITE DECISION LETTER | Approved | COMMUNITY DESIGN REVIEW COMMITTEE CITY OF TUCSON - DEVELOPMENT SERVICES ***REVISED*** June 11, 2007 October 9, 2009 Mike Harris Capital S, LLC 4800 College Blvd., Suite 101 Farmington, NM 87402 Re: DSMR 07- 21- 209 East Limberlost Drive (T09CM02016) Request: DS 3-01.2.2.A - Modify Average Daily Trips for condominium development, DS 3-01.3.3.A- Modify Development Standards to allow the four (4) foot wide sidewalk in the Limberlost Drive ROW to remain as is. The Development Standard Modification Request (DSMR) listed above has been APPROVED by the CRDC committee without condition. Please note that DS06-20 also applies to this project. PLEASE NOTE THAT A GENERAL NOTE MUST BE ADDED TO THE SITE PLAN WHICH STATES THE DSMR CASE NUMBER, DATE OF APPROVAL, MODIFICATIONS GRANTED, AND CONDITIONS IMPOSED. IN ADDITION, THE CASE NUMBER MUST BE ADDED TO EACH SHEET OF THE SITE PLAN, LANDSCAPE PLAN, AND NPPO PLAN, IN THE LOWER RIGHT CORNER NEAR THE TITLE BLOCK. If you have any additional questions, please contact me at 837-4919. Sincerely, Patricia Gehlen Zoning/CDRC Manager Development Services Department Attachments: 1 XC: file Records Fax (505) 326-1611 |