Permit Review Detail
Review Status: Completed
Review Details: DEV STDS MODIFICATION REVIEW
Permit Number - DS07-20
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/23/2007 | MARILYN KALTHOFF | START | PLANS SUBMITTED | Completed | |
| 05/24/2007 | JIM EGAN | FIRE | REVIEW | Approved | |
| 05/25/2007 | ANDY VERA | ENV SVCS | REVIEW | Approved | ES has no objections to this DSMR. |
| 05/29/2007 | MATT FLICK | ENGINEERING | REVIEW | Approv-Cond | DSD Engineering conditionally approves the DSMR to Dev. Stds. 2-03.2.4.F, 3-01.2.7.A and 3-01.6.5.D for the purpose of elimination of sidewalk and the installation of wedge curb. The following conditions are requested: An area of sufficient width must be provided within the sidewalk area (currently shown as 7.5') or the PUE (currently shown as 10') for pedestrian travel. The 10-year discharge must be conveyed beneath the area provided for pedestrian travel |
| 05/29/2007 | JOSE ORTIZ | TRAFFIC | TRAFFIC | Approved | The proposed DSMR is for private roadways therefore traffic has no objections to the proposed DSMR. |
| 06/04/2007 | FRODRIG2 | COMMUNITY PLANNING | REVIEW | Approved | DEPARTMENT OF URBAN PLANNING & DESIGN COMMENTS Regarding SUBJECT: Development Standard Modification Request (DSMR) CASE NUMBER: CASE NAME: DATE SENT DS07-20 Littletown/Wilmot Industrial (XXXX) Tentative Plat () Development Plan () Landscape Plan () Revised Plan/Plat () Board of Adjustment () Other - NPPO CROSS REFERENCE: Annexation C15-95-16 & S06-270 NEIGHBORHOOD PLAN: Rincon Southeast GATEWAY/SCENIC ROUTE: COMMENTS DUE BY: 05/31/07 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: () No Annexation or Rezoning Conditions, Not an RCP - No Comment (XXXX) Proposal Complies with Annexation or Rezoning Conditions () RCP Proposal Complies with Plan Policies () See Additional Comments Attached () No Additional Comments - Complies With Planning Comments Submitted on: () Resubmittal Required: () Tentative Plat () Development Plan () Landscape Plan () Other REVIEWER: drcorral 791-4505 DATE: 05/30/07 |
| 06/05/2007 | DAVID RIVERA | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL FROM: David Rivera Principal Planner DSD Zoning Review Section PROJECT: DSMR-07-20 6702 S. Wilmot Rd. Littletown and Wilmot Industrial Park Development Standard Modification Request Transmittal date: June 5, 2007 COMMENTS: Supported with conditions 1. Zoning will support the request to eliminate the concrete sidewalk requirement with the following condition. The pedestrian area is constructed per the Jerry L. Zillman's email response to Patricia Gehlen dated 6/6/07. "As we anticipate traffic over this pedestrian way we will place asphaltic concrete per the Geotech's recommendations for the parking lot areas, which is 2.5" AC over 5" of ABC." 2. Support for using wedge curbs in place of vertical curbs is supported by Zoning. If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. |
| 06/08/2007 | PATRICIA GEHLEN | ZONING-DECISION LETTER | WRITE DECISION LETTER | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE CITY OF TUCSON - DEVELOPMENT SERVICES June 8 2007 Jerry Zillman The WLB Group Inc 4444 East Broadway Blvd. Tucson, Arizona 85711 Re: DSMR 07- 20- 6702 South Wilmot (S06-270) Request: DS 3-01.4.1.C.1 - Modify material to be used for sidewalk from concrete to asphaltic concrete DS 3-01.3.2 - Modify curbing from vertical curb to wedge curb. The Development Standard Modification Requests (DSMRs) listed above has been APPROVED by the CRDC committee with the following condition(s): 1) The 10-year discharge must be conveyed beneath the area provided for pedestrian travel, 2) The material to be used for the sidewalk will be asphaltic concrete per the Geotech's recommendations for the parking lot areas, which is 2.5" AC over 5" of ABC. PLEASE NOTE THAT A GENERAL NOTE MUST BE ADDED TO THE TENTATIVE PLAT WHICH STATES THE DSMR CASE NUMBER, DATE OF APPROVAL, MODIFICATIONS GRANTED, AND CONDITIONS IMPOSED. IN ADDITION, THE CASE NUMBER MUST BE ADDED TO EACH SHEET OF THE TENTATIVE PLAT, LANDSCAPE PLAN, AND NPPO PLAN, IN THE LOWER RIGHT CORNER NEAR THE TITLE BLOCK. If you have any additional questions, please contact me at 837-4919. Sincerely, Patricia Gehlen Zoning/CDRC Manager Development Services Department Attachments: 1 XC: file Records Fax (520) 881-7492 |