Permit Number: DS07-19
Parcel: 106110070

Address: Unknown

Review Status: Completed

Review Details: DEV STDS MODIFICATION REVIEW

Permit Number - DS07-19
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/29/2007 MARILYN KALTHOFF START PLANS SUBMITTED Completed
05/29/2007 JIM EGAN FIRE REVIEW Approved
05/29/2007 JOSE ORTIZ TRAFFIC TRAFFIC Approved DSMR is on-site therefore traffic has no objections.
05/31/2007 MATT FLICK ENGINEERING REVIEW Approved DSD Engineering has no objection to elimination of sidewalk or the pedestrian refuge area along the southeast corner and east side of the proposed warehouse but offers the following comment:

The applicant should refer to Dev. Std. 2-08.3.1 which states:

"Areas within the development which are not required to
be connected to the pedestrian circulation path are those which will be used only for maintenance or for nonpublic truck use, such as truck loading spaces. Portions of certain
Land Use Classes which by their nature will not be used for public pedestrian access, such as industrial uses, commercial storage uses, wholesale uses, contractor's yards, or similar uses, are not required to have sidewalks constructed in conformance with this Standard, as long as adequate pedestrian refuge areas are provided."

The pedestrian refuge area is not necessarily for the benefit of the public. Pedestrian does not exclusively equal customers and the public.

DSD Engineering has no objection or adverse comment regarding a DSMR to Dev. Std. 6-01.0.
06/04/2007 FRODRIG2 COMMUNITY PLANNING REVIEW Approved DEPARTMENT OF URBAN PLANNING & DESIGN COMMENTS

Regarding

SUBJECT: Development Standard Modification Request (DSMR)


CASE NUMBER: CASE NAME: DATE SENT

DS07-19 American Home Furnishings 06/01/07

( ) Tentative Plat
( ) Development Plan
( ) Landscape Plan
( ) Revised Plan/Plat
( ) Board of Adjustment
(XXXX) Other - Site plan

CROSS REFERENCE:

NEIGHBORHOOD PLAN: General Plan

GATEWAY/SCENIC ROUTE:

COMMENTS DUE BY: 05/31/07

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

( ) No Annexation or Rezoning Conditions, Not an RCP - No Comment
(XXXX) Proposal Complies with Annexation or Rezoning Conditions
( ) RCP Proposal Complies with Plan Policies
( ) See Additional Comments Attached
( ) No Additional Comments - Complies With Planning Comments Submitted on:
( ) Resubmittal Required:
( ) Tentative Plat
( ) Development Plan
( ) Landscape Plan
( ) Other

REVIEWER: drcorral 791-4505 DATE: 05/30/07
06/07/2007 DAVID RIVERA ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

FROM: Steve Shields
Lead Planner
DSD Zoning Review Section

PROJECT: DSMR-DS07-19
2020 W. Prince Road
American Home Furnishings Warehouse Expansion
Development Standard Modification Request

Transmittal date: June 7, 2007

COMMENTS: Approved with conditions

1. D.S 2-08.4.1.B A two (2) foot minimum setback from the parking area access land (PAAL) to the southeast corner of the proposed warehouse addition must be maintained.

2. D.S. 6-01 Approval form Environmental Services and DSD Landscape review is required. If this request is to eliminate the screening requirement a board of adjustment for variance may be required.



If you have any questions about this transmittal, please call Steve Shields, (520) 837-4956.
06/15/2007 ANDY VERA ENV SVCS REVIEW Approved
06/19/2007 PATRICIA GEHLEN ZONING-DECISION LETTER WRITE DECISION LETTER Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
CITY OF TUCSON - DEVELOPMENT SERVICES


June 19 2007

Roberta Chinea
Psomas
800 East Wetmore Road, Suite 110
Tucson, Arizona 85719

Re: DSMR 07- 19- 2020 West Prince Road. (T06CM05594)

Request: DS 2-08.4.1.B - Modify on-site pedestrian circulation system so that it is eliminated along the south east corner and east side of the building,

The Development Standard Modification Request (DSMR) listed above has been APPROVED by the CRDC committee with the following condition(s):

1) Two (2) foot setback from the PAAL to the southeast corner of the proposed warehouse must be maintained.

Request: DS 6-01 - Eliminate required screening for compactor.

The Development Standard Modification Request (DSMR) listed above has been DENIED by the CRDC committee because a Board of Adjustment Variance is required to eliminate screening.

PLEASE NOTE THAT A GENERAL NOTE MUST BE ADDED TO THE SITE PLAN WHICH STATES THE DSMR CASE NUMBER, DATE OF APPROVAL, MODIFICATIONS GRANTED, AND CONDITIONS IMPOSED. IN ADDITION, THE CASE NUMBER MUST BE ADDED TO EACH SHEET OF THE SITE PLAN, LANDSCAPE PLAN, AND NPPO PLAN, IN THE LOWER RIGHT CORNER NEAR THE TITLE BLOCK.

If you have any additional questions, please contact me at 791-5608.

Sincerely,


Patricia Gehlen
Zoning/CDRC Manager
Development Services Department

Attachments: 1
XC: file
Records

Fax (520) 292-1290