Permit Number: DS07-17
Parcel: 10603035A

Address:
131 E MOHAVE RD

Review Status: Completed

Review Details: DEV STDS MODIFICATION REVIEW

Permit Number - DS07-17
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/07/2007 MARILYN KALTHOFF START PLANS SUBMITTED Completed
05/11/2007 DAVE MANN FIRE REVIEW Approved To: Patricia Gehlen
Develolpment Services Department
CDRC
From: Dave Mann
Date: 05/08/07
Comments: No objection
05/11/2007 MATT FLICK ENGINEERING REVIEW Approved DSD Engineering has no objection or adverse comment to approval of a DSMR to Dev. Std. 3-05.2.2.B.1 to allow a 4' pedestrian refuge area between the PAAL and structure.

DSD Engineering has no objection or adverse comment to approval of a DSMR to Dev. Std. 3-05.2.2.B.3 to allow a distance of 11" between the PAAL and wall.

DSD Engineering has no objection or adverse comment to approval of curbside pickup in accordance with Dev. Std. 6-01.3.0, et. seq.

Ref: T06CM05925
05/11/2007 MKALTHO1 COMMUNITY PLANNING REVIEW Approved DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Development Standard Modification Request (DSMR)

CASE NUMBER: CASE NAME: DATE SENT

DS07-17 131 E. Mohave Ave.
Sunshine Child Care

( ) Tentative Plat
( ) Development Plan
( ) Landscape Plan
( ) Revised Plan/Plat
( ) Board of Adjustment
(ΓΌ) Other - Site Plan

CROSS REFERENCE: NA

NEIGHBORHOOD PLAN: Cragin-Keeling

GATEWAY/SCENIC ROUTE: NA

COMMENTS DUE BY: 05/14/07

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

( X ) Proposal Complies with Annexation or Rezoning Conditions
( ) Proposal in Substantial Compliance with Plan Policies
( ) Additional Comments
( ) No Additional Comments - Complies With Planning Comments Submitted on:
( ) Resubmittal Required:
( ) Tentative Plat
( ) Development Plan
( ) Landscape Plan
( ) Other


REVIEWER: drcorral 791-4505 DATE: May 10, 2007
05/11/2007 DAVE MANN FIRE REVIEW Approved From: Tucson Fire Department, Dave Mann
Date: 05/08/07
Comments: No objection.
05/14/2007 DAVID RIVERA ZONING REVIEW Approv-Cond David Rivera
Zoning Rreview Section
DS07-17

Approved with conditions

1. Draw and annotate the location of the APC storage area and location of pickup.
05/16/2007 JOSE ORTIZ TRAFFIC TRAFFIC Approved
05/17/2007 ANDY VERA ENV SVCS REVIEW Approved ES has no objections to this DSMR.

1. Approved for APC curbside refuse/recycle service due to lack of space for accomodating for onsite refuse storage and maximum student capacity of 57.
05/18/2007 PATRICIA GEHLEN ZONING-DECISION LETTER WRITE DECISION LETTER Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
CITY OF TUCSON - DEVELOPMENT SERVICES

May 18 2007

Paul Dominguez
Archwest P.C.
1051 North Columbus Blvd.
Tucson, Arizona 85711

Re: DSMR 07- 17- 131 E. Mohave Road (T06CM05925)

Request: DS 3-05.2.2.B.1 -Modify pedestrian circulation system along the east side of the building to be four (4) feet wide.
DS 3-05.2.2.B.3 - Modify shy space between PAAL and wall along east property line to 11" (including wall).
DS 6-01.3 - Allow for APC's for trash collection.

The Development Standard Modification Request (DSMR) listed above has been APPROVED by the CRDC committee with the following condition(s):

1) Draw and annotate the location of the APC storage area and location for pickup on the site plan.


PLEASE NOTE THAT A GENERAL NOTE MUST BE ADDED TO THE SITE PLAN WHICH STATES THE DSMR CASE NUMBER, DATE OF APPROVAL, MODIFICATIONS GRANTED, AND CONDITIONS IMPOSED. IN ADDITION, THE CASE NUMBER MUST BE ADDED TO EACH SHEET OF THE SITE PLAN, LANDSCAPE PLAN, AND NPPO PLAN, IN THE LOWER RIGHT CORNER NEAR THE TITLE BLOCK.

If you have any additional questions, please contact me at 791-5608.

Sincerely,


Patricia Gehlen
Zoning/CDRC Manager
Development Services Department

Attachments: 1
XC: file
Records

Fax (520) 622-9655 and (520) 579-1976