Permit Number: DS07-13
Parcel: 10610005A

Address:
2020 W PRINCE RD

Review Status: Completed

Review Details: DEV STDS MODIFICATION REVIEW

Permit Number - DS07-13
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/16/2007 MARILYN KALTHOFF START PLANS SUBMITTED Completed
04/17/2007 MATT FLICK ENGINEERING REVIEW Approved DSD Engineering has no objection or adverse comment to granting the DSMR to Dev. Std. 3-01.3.2.E to allow the existing driveways to exceed the maximum widths listed in Table 5.3 of the TAMG.
04/17/2007 JOSE ORTIZ TRAFFIC TRAFFIC Approved The DSMR is along a local road that services other non-residential lots; therefore Traffic has no objections to the DSMR for driveway widths wider then the standard 35' per 3-01.3.2.E
04/19/2007 JIM EGAN FIRE REVIEW Approved
04/20/2007 MKALTHO1 COMMUNITY PLANNING REVIEW Approved DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Development Standard Modification Request (DSMR)

CASE NUMBER: CASE NAME: DATE SENT

DS07-13 2020 W. Prince Road Home Furnishings Warehouse Addition

( ) Tentative Plat
(XX) Development Plan
( ) Landscape Plan
( ) Revised Plan/Plat
( ) Board of Adjustment
( ) Other -

CROSS REFERENCE:

NEIGHBORHOOD PLAN: General Plan

GATEWAY/SCENIC ROUTE: No

COMMENTS DUE BY: April 20, 2007

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

( X ) Proposal Complies with Annexation or Rezoning Conditions
( ) Proposal in Substantial Compliance with Plan Policies
( ) Additional Comments
( ) No Additional Comments - Complies With Planning Comments Submitted on:
( ) Resubmittal Required:
( ) Tentative Plat
( ) Development Plan
( ) Landscape Plan
( ) Other


REVIEWER: drcorral 791-4505 DATE: 04/19/07
04/20/2007 ANDY VERA ENV SVCS REVIEW Approv-Cond * No objections to this DSMR. However I will note the following facts refencing on site refuse collection:

* Sheet 1A under key notes (21) makes mention of a new dumpster enclosure which shows it just west of loading zone area. Yet there is no detail of enclosure, nothing identifying specific placement for enclosure nor any shown maneuverability for service vehicle. Clarify and demonstrate. Per DS 6-01.0.

* Sheet 2 key note (22) mentions existing private compactor and dumpster but provides no detail to ensure full code compliance to DS 6-01.0.
04/30/2007 DAVID RIVERA ZONING REVIEW Approved
05/03/2007 PATRICIA GEHLEN ZONING-DECISION LETTER WRITE DECISION LETTER Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
CITY OF TUCSON - DEVELOPMENT SERVICES

May 3 2007

Daninel L. Bjelk
Psomas, Inc.,
800 East Wetmore Road, Ste #110
Tucson, Arizona 85719

Re: DSMR 07- 13- 2020 West Prince Road (T06CM05594)

Request: DS 3-01.3.2.E Chapter 25 - Modify driveway widths to exceed 35 feet to allow for truck manuvering.

The Development Standard Modification Request (DSMR) listed above has been APPROVED by the CRDC committee with the following conditions:

1) Details for trash enclosures and compactor must be shown on the site plan so compliance with DS 6-01 for the enclosure and access may be verified.


PLEASE NOTE THAT A GENERAL NOTE MUST BE ADDED TO THE SITE PLAN WHICH STATES THE DSMR CASE NUMBER, DATE OF APPROVAL, MODIFICATIONS GRANTED, AND CONDITIONS IMPOSED. IN ADDITION, THE CASE NUMBER MUST BE ADDED TO EACH SHEET OF THE SITE PLAN, LANDSCAPE PLAN, AND NPPO PLAN, IN THE LOWER RIGHT CORNER NEAR THE TITLE BLOCK.

If you have any additional questions, please contact me at 791-5608.

Sincerely,


Patricia Gehlen
Zoning/CDRC Manager
Development Services Department

Attachments: 1
XC: file
Records

Fax 292-1290