Permit Review Detail
Review Status: Completed
Review Details: DEV STDS MODIFICATION REVIEW
Permit Number - DS07-11
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/27/2007 | MARILYN KALTHOFF | START | PLANS SUBMITTED | Completed | |
| 03/28/2007 | JIM EGAN | FIRE | REVIEW | Approved | |
| 04/03/2007 | ANDY VERA | ENV SVCS | REVIEW | Approved | * ES has no objections to this DSMR. * Curbside frontage APC service remains feasible. |
| 04/04/2007 | MKALTHO1 | COMMUNITY PLANNING | REVIEW | Approved | DEPARTMENT OF URBAN PLANNING & DESIGN Regarding SUBJECT: Development Standard Modification Request (DS) CASE NUMBER: CASE NAME: DATE SENT DS07-11 Las Nubes 04/03/07 (XXXX) Tentative Plat ( ) Development Plan ( ) Landscape Plan ( ) Revised Plan/Plat ( ) Board of Adjustment ( ) Other - NPPO CROSS REFERENCE: C9-04-22 NEIGHBORHOOD PLAN: Tucson Mountains Subregional Plan Map Detail 1 GATEWAY/SCENIC ROUTE: Goret COMMENTS DUE BY: 04/03/07 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: ( ) Proposal Complies with Annexation or Rezoning Conditions (XXXX) Proposal in Substantial Compliance with Plan Policies ( ) See Additional Comments Attached ( ) No Additional Comments - Complies With Planning Comments Submitted on: ( ) Resubmittal Required: ( ) Tentative Plat ( ) Development Plan ( ) Landscape Plan ( ) Other REVIEWER: drcorral 791-4505 DATE: 04/03/07 |
| 04/05/2007 | JOSE ORTIZ | TRAFFIC | TRAFFIC | Approved | |
| 04/06/2007 | DAVID RIVERA | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL FROM: David Rivera Principal Planner DSD Zoning Review Section PROJECT: DSMR-07-11 Las Nubes Lots 1-14 Tentative Plat - RCP Subdivision Development Standard Modification Request Transmittal date: April 4, 2007 COMMENTS: Approved with conditions 1. Zoning supports the requested DSMR for D.S. 3-01.2.4, 3-01.2.7, 3-01.3.2 and 3-01.3.3. 2. Zoning supports the requested DSMR for D.S. 3-01.2 and .3 with conditions that documentation related to the proposed improvements to Goret Road are submitted with the re-submittal of the tentative plat or approval of the DSMR by TDOT confirming the future improvements. 3. All notes related to a residential cluster project must be removed from the plan. If this development is to be a RCP the sidewalk system within the subdivision must meet the construction material and width and must be on both sides of the street. |
| 04/11/2007 | MATT FLICK | ENGINEERING | REVIEW | Approv-Cond | DSD Engineering conditionally approves the request for a DSMR to Dev. Std. 3-01.3.2 & 3-01.3.3 provided that a graded shoulder of sufficient width for pedestrians and drainage is provided. DSD Engineering has no objection or adverse comment to the request for a DSMR to Dev. Std. 3-01.0 to allow the onsite roadway cross-section as shown. |
| 04/13/2007 | PATRICIA GEHLEN | ZONING-DECISION LETTER | WRITE DECISION LETTER | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE CITY OF TUCSON - DEVELOPMENT SERVICES April 13 2007 Michael Marks, AICP MJM Consulting 7002 East 4th Street Tucson, Arizona 85710 Re: DSMR 07- 11- 2740 West Goret Road (S06-050) Request: DS 3-01 - Modify the street cross section as detailed on the tentative plat and attachment A of the DSMR application DS 3-01.3.2. and DS 3-01.3.3 - Postpone right-of-way improvement (curb and sidewalk) in Goret Road per attachment A The Development Standard Modification Requests (DSMRs) listed above has been APPROVED by the CRDC committee with the following conditions: 1) Provide documentation of proposed roadway improvements to Goret Road with resubmittal of tentative plat, 2) All notes related to a residential cluster project (RCP) must be removed from the plan. If this development is to be an RCP, the sidewalk system within the subdivision must meet the construction material and width required by the Development Standards and must be on both sides of the street, 3) A graded shoulder of sufficient width for pedestrians and drainage must be provided along Goret Road. PLEASE NOTE THAT A GENERAL NOTE MUST BE ADDED TO THE TENTATIVE PLAT WHICH STATES THE DSMR CASE NUMBER, DATE OF APPROVAL, MODIFICATIONS GRANTED, AND CONDITIONS IMPOSED. IN ADDITION, THE CASE NUMBER MUST BE ADDED TO EACH SHEET OF THE TENTATIVE PLAT, LANDSCAPE PLAN, AND NPPO PLAN, IN THE LOWER RIGHT CORNER NEAR THE TITLE BLOCK. If you have any additional questions, please contact me at 791-5608. Sincerely, Patricia Gehlen Zoning/CDRC Manager Development Services Department Attachments: 1 XC: file Records Fax 885-5021 |