Permit Review Detail
Review Status: Completed
Review Details: DEV STDS MODIFICATION REVIEW
Permit Number - DS07-08
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/15/2007 | MARILYN KALTHOFF | START | PLANS SUBMITTED | Completed | |
| 03/16/2007 | JIM EGAN | FIRE | REVIEW | Approved | |
| 03/16/2007 | MATT FLICK | ENGINEERING | REVIEW | Denied | DSD Engineering Comments for DS07-08 - 3227 N Palo Verde Avenue DSD Engineering does not support the approval of a DSMR to Dev. Std. 3-05.2.2.B.1 and Dev. Std. 3-05.2.2.B.3. The applicant states that since the width of the PAAL is substandard, there isn't sufficient room for the pedestrian refuge area (Dev. Std. 3-05.2.2.B.1) and the 2' separation (Dev. Std. 3-05.2.2.B.3). It is DSD Engineering's position that the narrow PAAL makes it more important to have sufficient pedestrian refuge space and vehicle/wall separation. If there were a standard 24' PAAL, the need for the pedestrian refuge area and wall separation would be less critical as there would be some space for vehicles to avoid the wall and pedestrians. It should also be noted that DSD Engineering has opposed the granting of a variance to the PAAL width. If the PAAL along the northern side of the building was one-way and paired with another one-way PAAL (perhaps along the southern side of the building), DSD Engineering might reconsider its position on the pedestrian refuge and wall separation issues. DSD Engineering has no objection to the approval of a DSMR to Dev. Std. 6-01.4.0 to allow on-street garbage pickup. |
| 03/21/2007 | MKALTHO1 | COMMUNITY PLANNING | REVIEW | Approv-Cond | DEPARTMENT OF URBAN PLANNING & DESIGN Regarding SUBJECT: Development Standard Modification Request (DS) CASE NUMBER: CASE NAME: DATE SENT DS07-08 Interior Designs ( ) Tentative Plat ( ) Development Plan ( ) Landscape Plan ( ) Revised Plan/Plat ( ) Board of Adjustment (XXXX) Other - Site Plan CROSS REFERENCE: C10-07-08 & DRB 07-05 NEIGHBORHOOD PLAN: Northside Area Plan GATEWAY/SCENIC ROUTE: COMMENTS DUE BY: March 22, 2007 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: ( ) No Annexation or Rezoning Conditions, Not an RCP - No Comment ( ) Proposal Complies with Annexation or Rezoning Conditions ( ) RCP Proposal Complies With Plan Policies (XXXX) See Additional Comments Attached ( ) No Additional Comments - Complies With Planning Comments Submitted on: ( ) Resubmittal Required: ( ) Tentative Plat ( ) Development Plan ( ) Landscape Plan ( ) Other - REVIEWER: drcorral 791-4505 DATE: March 21, 2007 COMMENTS The site is within Subarea 5, Binghampton of the Northside Area Plan (NSNP). The General Plan and the Design Guidelines Manual also provide guidance for this project. Request: To eliminate the requirement for a minimum five-foot-wide pedestrian refuge area between Parking Area Access Lane (PAAL) and the north patio wall of the principal structure. Response: A parallel request has been filed with the Board of Adjustment (BOA) for a variance from the minimum 24-foot width requirement for a PAAL. Request: To eliminate the requirement for a two-foot separation required between the PAAL and the screen wall on the north boundary. Response: A parallel request for a variance has been filed with the BOA to allow an 11-foot PAAL between a screen wall on the north boundary and the patio wall enclosing a covered porch on the north side of the principal building. Staff's comments on BOA case C10-07-08, were as follows: ยจ Elimination of the interior (north) landscape border can be supported if PAAL is not reduced to less than 18 feet The above recommendation is based on the fact that removal of the covered porch on the north side of the principal building would allow for an 18-foot wide PAAL. The plan goals for the NSNP are to provide safe and efficient circulation systems for all modes of transport, including pedestrian. Policy 5.b of the Plan specifically states to ensure well-designed nonresidential developments by providing common access points and parking, integrated vehicular and pedestrian circulation systems. As such, the plans can support the requests to 1) eliminate the requirement for a minimum five-foot-wide pedestrian refuge area between Parking Area Access lane (PAAL) and the north patio wall of the principal structure and 2) eliminate the requirement for a two-foot separation required between the PAAL and the screen wall on the north boundary, if the PAAL is not reduced to less than 18 feet in width. The Plans can support the applicant's DSMR request for curbside refuse collection subject to Environmental Services approval |
| 03/22/2007 | ANDY VERA | ENV SVCS | REVIEW | Approved | * ES has no objection to this DSMR. Curbside collection has and can continue to be a viable option for refuse collection to this office environment. |
| 03/23/2007 | JOSE ORTIZ | TRAFFIC | TRAFFIC | Approved | |
| 03/30/2007 | DAVID RIVERA | ZONING | REVIEW | Denied | CDRC TRANSMITTAL FROM: David Rivera Principal Planner DSD Zoning Review Section PROJECT: DSMR-07-08 3227 N. Palo Verde Interior Trends Office Development Standard Modification Request Transmittal date: March 30, 2007 COMMENTS: Zoning cannot support the DSMR request at this time. 1. It is Zoning's understanding that the Board of Adjustment variance process has been continued. At this time Zoning cannot support the requested DSMR application. It is not clear at this time what conditions of approval may be imposed if the variance request is successful. It is requested that the DSMR application be re-submitted once the Board of Adjustments has ruled on the variance requests. If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. |
| 04/02/2007 | PATRICIA GEHLEN | ZONING-DECISION LETTER | WRITE DECISION LETTER | Denied | COMMUNITY DESIGN REVIEW COMMITTEE CITY OF TUCSON - DEVELOPMENT SERVICES April 2, 2007 Frank S. Bangs, Jr. Lewis and Roca LLP One South Church Avenue, Suite 700 Tucson, Arizona 85701-1611 Re: DSMR 07- 08- 3225/3227 North Palo Verde Avenue (T06CM06306) Request: DS 3-05.2.2.B.1 Modify pedestrian circulation system by eliminating pedestrian refuge along north side of the building. DS 3-05.2.2.B.3 Modify width of vehicle access along north side of property by eliminating the two (2) foot separation required between a PAAL and a wall. The Development Standard Modification Requests (DSMR) listed above have been Denied by the CRDC committee until the Board of Adjustment Variance has been obtained. DSMR may be resubmitted after the meeting with the Board of Adjustment has been completed. Request: DS6-01.4.0 Continue to allow for curb side trash pick up. The Development Standard Modification Request (DSMR) listed above has been approved by the CDRC committee without condition. PLEASE NOTE THAT A GENERAL NOTE MUST BE ADDED TO THE SITE PLAN WHICH STATES THE DSMR CASE NUMBER, DATE OF APPROVAL, MODIFICATIONS GRANTED, AND CONDITIONS IMPOSED. IN ADDITION, THE CASE NUMBER MUST BE ADDED TO EACH SHEET OF THE SITE PLAN, LANDSCAPE PLAN, AND NPPO PLAN, IN THE LOWER RIGHT CORNER NEAR THE TITLE BLOCK. If you have any additional questions, please contact me at 791-5608. Sincerely, Patricia Gehlen Zoning/CDRC Manager Development Services Department Attachments: 1 XC: file Records Fax 879-4701 |