Permit Number: DS07-01
Parcel: 12514016B

Address:
3164 E 4TH ST

Review Status: Completed

Review Details: DEV STDS MODIFICATION REVIEW

Permit Number - DS07-01
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/29/2007 MARILYN KALTHOFF START PLANS SUBMITTED Completed
01/30/2007 JIM EGAN FIRE REVIEW Approved
01/30/2007 JOSE ORTIZ TRAFFIC TRAFFIC Approved Traffic Engineering has no objection to DS07-01 - Fourth Street RCP (S05-244) (modification request to Development Standards 6-01.2.2.B.3 & 6-01.2.2.C).

Jose Ortiz, P.E.
Engineering Project Manager
Department of Transportation
(520) 791-4259 Ext 76730
Fax (520) 791-5526
email: jose.ortiz@tucsonaz.gov
01/31/2007 MATT FLICK ENGINEERING REVIEW Approved DSD Engineering has no objection to approval of the DSMR to Dev. Std. 6-01.2.2.B.3 and Dev. Std. 6-01.2.2.C to allow refuse collection in the alley having less than 25' vertical clearance and having a width of less than 20'.

Ref: S05-244
02/06/2007 MKALTHO1 COMMUNITY PLANNING REVIEW Approved DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Development Standard Modification Request (DS)

CASE NUMBER: CASE NAME: DATE SENT

DS07-01 Fourth Street RCP


(X) Tentative Plat
() Development Plan
() Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
() Other - Site Plan

CROSS REFERENCE: S05-244

NEIGHBORHOOD PLAN: Santa Cruz

GATEWAY/SCENIC ROUTE: No

COMMENTS DUE BY February 5, 2007

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

( ) Proposal Complies with Annexation or Rezoning Conditions
(XXXX) Proposal in Substantial Compliance with Plan Policies
( ) See Additional Comments Attached
( ) No Additional Comments - Complies With Planning Comments Submitted on:

( ) Resubmittal Required:
( ) Tentative Plat
( ) Development Plan
( ) Landscape Plan
( ) Other


REVIEWER: drcorral 791-4505 DATE: 02/05/07
02/07/2007 AVERA1 ENV SVCS REVIEW Approved * Okay for refuse collection to be performed within alley. Access and approach to enclosure will work.
02/08/2007 DAVID RIVERA ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

FROM: David Rivera
Principal Planner
DSD Zoning Review Section
PROJECT: DSMR-07-01
3164 & 3168 E. 4th Street
Fourth Street RCP - Tentative Plat - S05-244
Development Standard Modification Request

Transmittal date: February 8, 2007

COMMENTS: Based on the memo from John Clark, Environmental Services approving the location, Zoning supports the DSMR with the following condition.

1. A variance must be applied for and approved for the required screen wall along the south side of the property as described by the landscape reviewer in his review comments for the tentative plat, specifically comment 9, case number S05-044.

Landscape Reviewer comment:
9) "The refuse collection area may not be accessed from the alley. Per LUC Table 3.7.2-I a 5' high masonry wall is required to screen the vehicular use area proposed to provide access to the Dumpster."

It may be necessary to apply and get approval for the B. of A. variance and prior to actual approval of the DSMR.

If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.
02/12/2007 PATRICIA GEHLEN ZONING-DECISION LETTER WRITE DECISION LETTER Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
CITY OF TUCSON - DEVELOPMENT SERVICES



February 12, 2007

Steven J. Gregor, P.E.
Gregor Engineering, Inc.
5232 East Pima Street, Suite A
Tucson, Arizona 85718

Re: DSMR 07- 01- 3164 and 3168 East 4th Street (S05-244)

Request: DS 6-01.2.2.B.3 - Reduce overhead clearance above dumpster,
DS 6-01.2.2.C - Modify minimum alley requirements for garbage pick-up.

The Development Standard Modification Requests (DSMRs) listed above have been Approved by the CRDC committee with the following conditions:

1) Compliance with landscape and screening requirements per tentative plat review required.

PLEASE NOTE THAT A GENERAL NOTE MUST BE ADDED TO THE TENTATIVE PLAT WHICH STATES THE DSMR CASE NUMBER, DATE OF APPROVAL, MODIFICATIONS GRANTED, AND CONDITIONS IMPOSED. IN ADDITION, THE CASE NUMBER MUST BE ADDED TO EACH SHEET OF THE TENTATIVE PLAT, LANDSCAPE PLANS, AND NPPO PLANS, IN THE LOWER RIGHT CORNER NEAR THE TITLE BLOCK.

If you have any additional questions, please contact me at 791-5608.

Sincerely,


Patricia Gehlen
Zoning/CDRC Manager
Development Services Department

Attachments: 1
XC: file
Records