Permit Number: DS06-48
Parcel: 13613020C

Address: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - DEVELOPMENT STANDARDS REVIEW

Permit Number - DS06-48
Review Name: RESUBMITTAL - DEVELOPMENT STANDARDS REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/26/2007 MARILYN KALTHOFF START PLANS SUBMITTED Completed
03/26/2007 JOSE ORTIZ COT NON-DSD TRAFFIC Approved The proposed roadways are private therefore Traffic Engineering has no objection to DS06-48 - Oasis - Golf Links (S06-144) (modification request to Development Standards 3-01.2.3.A & 3-01 Fig 22) for 10' lanes versus required 12' travel lanes and reduced curb radius (60' to 50').

Jose Ortiz, P.E.
Engineering Project Manager
Department of Transportation
(520) 791-4259 Ext 305
Fax (520) 791-5526
email: jose.ortiz@tucsonaz.gov
03/27/2007 JIM EGAN COT NON-DSD FIRE Approved
03/30/2007 ANDY VERA ENV SVCS REVIEW Approved * No objections to this DSMR. Remains good for street frontage access and APC curside refuse seervice.
04/03/2007 DAVID RIVERA ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

FROM: David Rivera
Principal Planner
DSD Zoning Review Section
PROJECT: DSMR-06-48
Oasis Golf Links Subdivision - RCP
S06-144
Development Standard Modification Request

Transmittal date: April 3, 2007

COMMENTS: Approved with conditions

1. Zoning supports the proposed DSMR request for DS 3-01.2.3.A.1 if support and approval by the fire department and Environmental Services is granted.

2. Zoning supports the proposed DSMR request for DS 3-01.2.8 with the following condition. The access ramps at the north and southwest corners are aligned to provide a continuous pedestrian circulation. Also truncated domes must be added to the entire length of the depressed sidewalk. The truncated domes must comply with ANSI section 406.12.

3. Zoning supports the proposed DSMR request for DS 3-01 fig 1, 2, 5 with private streets as depicted on the plan.

If you have any questions about this transmittal, please call David Rivera, (520) 837-4957.
04/04/2007 ROGER HOWLETT COT NON-DSD URBAN PLANNING & DESIGN Approved *****REVISED****
DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding
SUBJECT: Development Standard Modification Request (DSMR)

CASE NUMBER: CASE NAME: DATE SENT

DS06-48 Oasis Golf Links

(XXXX) Tentative Plat
( ) Development Plan
(XXXX) Landscape Plan
( ) Revised Plan/Plat
( ) Board of Adjustment
( ) Other

CROSS REFERENCE:

NEIGHBORHOOD PLAN: South Pantano

GATEWAY/SCENIC ROUTE:

COMMENTS DUE BY: 04/02/07

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

( ) No Annexation or Rezoning Conditions, Not an RCP - No Comment
(XXXX) Proposal Complies with Annexation or Rezoning Conditions
( ) RCP Proposal Complies With Plan Policies
( ) See Additional Comments Attached
( ) No Additional Comments - Complies With Planning Comments Submitted on:
( ) Resubmittal Required:
( ) Tentative Plat
( ) Development Plan
( ) Landscape Plan
( ) Other

REVIEWER: D. R. Corral 791-4505 DATE: 04/03/07
04/06/2007 MATT FLICK ENGINEERING REVIEW Approved DSD Engineering has no objection to granting a DSMR to Dev. Std. 3-01.2.3.A.1 to allow 10' wide travel lanes in lieu of 12' wide lanes on the private street.

DSD Engineering has no objection to granting a DSMR to Dev. Std. 3-01.2.8 to allow a depressed sidewalk opposite Lot 34 to allow drainage to pass over this sidewalk.

DSD Engineering has no objection to granting a DSMR to Dev. Std. 3-01, Figs, 1, 2 & 5 to allow 90-degree vehicle parking to back into the private street.
04/12/2007 PGEHLEN1 ZONING-DECISION LETTER WRITE DECISION LETTER Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
CITY OF TUCSON - DEVELOPMENT SERVICES
***REVISED***


April 12, 2007

Dan Castro
Rick Engineering Company, Inc
1745 East River Road, Suite 101
Tucson, Arizona 85718

Re: DSMR 06-48 - Oasis - Golf Links Tentative Plat (S06-144) -

Request: DS 3-01.2.3.A.1 - Modify travel lane width on private streets to 10 feet.
DS 3-01 Figure 22 - Modify radius on knuckle to 50 feet.
DS 3-01 Figures 1, 2, and 5 - Modify street standard to allow 90 degree guest parking to back out into private right-of-way.
DS 3-01.2.8 - Allow for a depressed sidewalk in the southwest corner of the site to allow for natural drainage patterns.


The Development Standard Modification Requests (DSMRs) listed above have been Approved by the CRDC committee with the following condition:

1) The access ramps at the north and southwest corners are aligned to provide continuous pedestrian circulation.
2) Truncated domes must be added to the entire length of the depressed sidewalk. The truncated domes must comply with ANSI section 406.12.

PLEASE NOTE THAT A GENERAL NOTE MUST BE ADDED TO THE TENTATIVE PLAT WHICH STATES THE DSMR CASE NUMBER, DATE OF APPROVAL, MODIFICATIONS GRANTED, AND CONDITIONS IMPOSED. IN ADDITION, THE CASE NUMBER MUST BE ADDED TO EACH SHEET OF THE TENTATIVE PLAT, LANDSCAPE PLAN, AND NPPO PLAN, IN THE LOWER RIGHT CORNER NEAR THE TITLE BLOCK.

If you have any additional questions, please contact me at 791-5608.

Sincerely,

Patricia Gehlen
Zoning/CDRC Manager
Development Services Department

Fax Number: 322-6956