Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: DS06-46
Parcel: 12101006A

Address:
6105 E PIMA ST

Review Status: Completed

Review Details: DEV STDS MODIFICATION REVIEW

Permit Number - DS06-46
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/25/2006 MARILYN KALTHOFF START PLANS SUBMITTED Completed
10/26/2006 JCLARK3 ENV SVCS REVIEW Approved
10/26/2006 MATT FLICK ENGINEERING REVIEW Approved Alamo Lofts is a proposed 22-unit condominium subdivision located at 6105 E Pima Street (near the Alamo Avenue alignment). Pima Street is designated as a Collector on the Major Streets and Routes Plan. The site is presently vacant and does not lie within a mapped floodplain and does not lie within a designated critical basin or balanced basin. Detention is not required; threshold retention is required due to the proposed density of the site. Onsite PAALs and drives are to be private.

The DSD Engineering Division has no objection or adverse comment to the granting of a DSMR to Dev. Std. 2-08.4.1.B in order to allow the relocation of the sidewalk from being adjacent to the PAAL to being located along the eastern side of the easternmost units.
10/26/2006 JOSE ORTIZ TRAFFIC TRAFFIC Approved The proposed DSMR is on-site and has no adverse effects to access; therefore Traffic Engineering has no objection to DS06-46 - 6105 East Pima St. Alamo Lofts (S06-018) (modification request to Development Standard 2-08.4.1.B) for required sidewalks adjacent to a PAAL.

Jose Ortiz, P.E.
Engineering Project Manager
Department of Transportation
(520) 791-4259 Ext 305
Fax (520) 791-5526
email: jose.ortiz@tucsonaz.gov
10/27/2006 DAVID RIVERA ZONING REVIEW Approved
10/31/2006 JIM EGAN FIRE REVIEW Approv-Cond Provide no parking signs.
11/03/2006 MKALTHO1 COMMUNITY PLANNING REVIEW Approved DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding
SUBJECT: Development Standard Modification Request (DSMR)

CASE NUMBER: CASE NAME: DATE SENT

DS06-046 Alamo Lofts 11/30/06

(XXXX) Tentative Plat
( ) Development Plan
( ) Landscape Plan
( ) Revised Plan/Plat
( ) Board of Adjustment
( ) Other -

CROSS REFERENCE: C9-05-19 & S06-018

NEIGHBORHOOD PLAN: Arcadia-Alamo Are Plan

GATEWAY/SCENIC ROUTE:

COMMENTS DUE BY: 10/31/06

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

( ) No Annexation or Rezoning Conditions, Not an RCP - No Comment
(XXXX) Proposal Complies with Annexation or Rezoning Conditions
( ) RCP Proposal Complies With Plan Policies
( ) See Additional Comments Attached
( ) No Additional Comments - Complies With Planning Comments Submitted on:
( ) Resubmittal Required:
( ) Tentative Plat
( ) Development Plan
( ) Landscape Plan
( ) Other

REVIEWER: D. R. Corral 791-4505 DATE: 10/27/06
11/06/2006 PATRICIA GEHLEN ZONING-DECISION LETTER WRITE DECISION LETTER Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
CITY OF TUCSON - DEVELOPMENT SERVICES



November 6, 2006

Dan Castro
Rick Engineering Company
1745 East River Road, Suite 101
Tucson, Arizona 85718

Re: DSMR 06-46 - Alamo Lofts Tentative Plat (S06-018) - 6105 East Pima Street

Request: DS 2-08.4.1.B - Modify location of pedestrian sidewalk so it does not have to be between the PAAL and the proposed buildings (move from west side of buildings to east side of site).


The Development Standard Modification Request (DSMR) listed above has been Approved by the CRDC committee with the following condition:

1) "No parking" signs are required to be posted per Fire Department requirements.







If you have any additional questions, please contact me at 791-5608.

Sincerely,


Patricia Gehlen
Zoning/CDRC Manager
Development Services Department

Attachments: 1

XC: file
Records