Permit Review Detail
Review Status: Completed
Review Details: DEV STDS MODIFICATION REVIEW
Permit Number - DS06-45
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/24/2006 | MARILYN KALTHOFF | START | PLANS SUBMITTED | Completed | |
| 10/25/2006 | JIM EGAN | FIRE | REVIEW | Approved | |
| 10/26/2006 | MATT FLICK | ENGINEERING | REVIEW | Approved | Las Sendas is a proposed 77-lot subdivision located at the southwest corner of Ajo Way and Pandora Avenue. Ajo Way is a designated Gateway Route. The site does not lie within a mapped floodplain or a designated balanced basin or critical basin. Threshold retention is required based upon the proposed site density. Streets and drives on the site are proposed to be private. The DSD Engineering Division has no objection or adverse comment to the granting of a DSMR to Dev. Std. 3-01.2.3 to allow perpendicular parking and the cross-sections as shown on Sections A-A, C-C and D-D. The DSD Engineering Division has no objection or adverse comment to the granting of a DSMR to Dev. Std. 3-01.6.2 to allow the private turnarounds as shown on the detail supplied with the DSMR application. |
| 10/26/2006 | JCLARK3 | ENV SVCS | REVIEW | Approved | |
| 10/26/2006 | JOSE ORTIZ | TRAFFIC | TRAFFIC | Approved | The proposed DSMR is on-site/private property and has no adverse effects to public ROW access; therefore Traffic Engineering has no objection to DS06-45 - 1435 W. Ajo Way Las Sendas Subdivision (S06-205) (modification request to Development Standards 3-01.2.3 & 3-01.6.2) for roadway width requirements and geometric design of the hammerhead. Jose Ortiz, P.E. Engineering Project Manager Department of Transportation (520) 791-4259 Ext 305 Fax (520) 791-5526 email: jose.ortiz@tucsonaz.gov |
| 10/27/2006 | DAVID RIVERA | ZONING | REVIEW | Approved | |
| 10/30/2006 | MKALTHO1 | COMMUNITY PLANNING | REVIEW | Approved | DEPARTMENT OF URBAN PLANNING & DESIGN Regarding SUBJECT: Development Standard Modification Request (DSMR) CASE NUMBER: CASE NAME: DATE SENT DS06-45 Las Sendas Subdivision (S06-205) 10/30/06 ( ) Tentative Plat ( ) Development Plan ( ) Landscape Plan ( ) Revised Plan/Plat ( ) Board of Adjustment (ü) Other - Plat and turn-around detail CROSS REFERENCE: C9-05-04, S06-205 NEIGHBORHOOD PLAN: Santa Cruz Area Plan GATEWAY/SCENIC ROUTE: Ajo Way is Gateway Route COMMENTS DUE BY October 31, 2006 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: ( ) Proposal Complies with Annexation or Rezoning Conditions ( ) Proposal in Substantial Compliance with Plan Policies (ü) See Comments Attached ( ) No Additional Comments - Complies with Planning Comments submitted on: (ü) Resubmittal Required: No Resubmittal Required ( ) Tentative Plat ( ) Development Plan ( ) Landscape Plan ( ) Other REVIEWER: J. Hershenhorn 791-4505 DATE: 10/30/06 DS-06-45 Las Sendas Subdivision (S06-205) 1) This section has no comments/no objections to the granting of this DSMR. |
| 11/06/2006 | PATRICIA GEHLEN | ZONING-DECISION LETTER | WRITE DECISION LETTER | Approved | COMMUNITY DESIGN REVIEW COMMITTEE CITY OF TUCSON - DEVELOPMENT SERVICES November 6, 2006 J. Lorenzo Ortiz, P.E. Indevco A & E, Inc. 5995 East Grant Road, #111 Tucson, Arizona 85712 Re: DSMR 06-45 - La Sendas Tentative Plat (S06-205) - 1435 West Ajo Way Request: DS 3-01 Figure 2 (as detailed throughout DS 3-01) - Modify street cross sections for this subdivision as detailed in cross sections A-A, C-C, and D-D on sheet 4 of 4 of the tentative plat. This is to include 90 degree parking backing into a private street. DS 3-01.6.2 - Modify turnarounds as detailed in attachment because they will not be used by the Fire or Environmental Services Departments The Development Standard Modification Requests (DSMRs) listed above have been Approved by the CRDC committee without condition: If you have any additional questions, please contact me at 791-5608. Sincerely, Patricia Gehlen Zoning/CDRC Manager Development Services Department Attachments: 1 XC: file Records |