Permit Number: DS06-27
Parcel: 11618351B

Review Status: Completed

Review Details: DEV STDS MODIFICATION REVIEW

Permit Number - DS06-27
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/26/2006 MARILYN KALTHOFF START PLANS SUBMITTED Completed
06/27/2006 DALE KELCH TRAFFIC TRAFFIC Approved Traffic Engineering has no objection to DSMR DS06-27 Westmoreland (S05-129)

4220436, 460-468 N. Westmoreland Ave.
06/28/2006 JIM EGAN FIRE REVIEW Approved
06/29/2006 MATT FLICK ENGINEERING REVIEW Approved DSD Engineering Comments for DS06-27 - Westmoreland

DSD Engineering offers the following:

Dev. Std. 3-01.2.3.A.1 - No objection to granting the DSMR to allow a 12' travel lane within C.A. "A" located behind the Lots.

Dev. Std. 3-01.2.7.A - No objection to granting the DSMR to allow the omission of sidewalk along the drives within C.A. "A" located behind the lots.

Dev. Std. 3-01.3.2 - No objection to granting the DSMR to allow the omission of curbing along the "garage side" of the drives located in C.A. "A" behind the lots. Curbing shall be provided in the areas between Westmoreland Avenue and Lots 1 and 8, and between Menlo Park Place and Lots 7 and 14.

Matt Flick
Engineering Manager
19JUN06
06/29/2006 JCLARK3 ENV SVCS REVIEW Approved Project was reviewed under S05-129. Project was approved for APC refuse service off the 12 foot roadway and utilizing the 4 foot for the APC's on the persons property. Roadway has radises of 35 feet at the corners.
07/11/2006 DAVID RIVERA ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

FROM: David Rivera
Principal Planner
DSD Zoning Review Section
PROJECT: DS06-27
422-468 N. Westmoreland Avenue
Westmoreland Tentative Plat

Development Standard Modification Request

Transmittal date: July 11, 2006

COMMENTS: Approved with conditions

1. Zoning requests that no parking signs be provided along the one-way drive lanes in order to maintain a clear 12-foot clearance for access to all units.

2. The sidewalk must be extended to the Common Area B-2 next lot 7 to provide access to the Functional Open Space. The functional spaces must be accessible for the handicapped.





If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.
07/13/2006 MKALTHO1 COMMUNITY PLANNING REVIEW Approved DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Development Standard Modification Request (DSMR)

CASE NUMBER: CASE NAME: DATE SENT

DS06-27 Westmoreland 07/07/06

( ) Tentative Plat
( ) Development Plan
( ) Landscape Plan
( ) Revised Plan/Plat
( ) Board of Adjustment
(XXXX) Other - Site Plan

CROSS REFERENCE: S05-129

NEIGHBORHOOD PLAN: Santa Cruz

GATEWAY/SCENIC ROUTE:

COMMENTS DUE BY July 3, 2006

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

( ) Proposal Complies with Annexation or Rezoning Conditions
(XXXX) Proposal in Substantial Compliance with Plan Policies
( ) ( ) See Additional Comments Attached
( ) No Additional Comments - Complies With Planning Comments Submitted on:

( ) Resubmittal Required:
( ) Tentative Plat
( ) Development Plan
( ) Landscape Plan
( ) Other


REVIEWER: MSP 791-4505 DATE: 07/08/06
07/21/2006 PATRICIA GEHLEN ZONING-DECISION LETTER WRITE DECISION LETTER Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
CITY OF TUCSON - DEVELOPMENT SERVICES



July 21, 2006

Craig A. Hunt, P.E.
Engineering and Environmental Consultants
4625 East Fort Lowell Road
Tucson, Arizona 85712

Re: DSMR 06-27 - 422-426, 460-468 N. Westmoreland Avenue (S05-129)

Request: DS 3-01.2.3.A.1 - Revise street standard to allow for a one-way 12 foot wide travel lane road way,
DS 3-01.2.7 - Modify street sidewalk requirement to provide sidewalk on public street but not on private street
DS 3-01.3.2.A - Modify curb height along private street from 6" to ".



The Development Standard Modification Requests (DSMRs) listed above has been Conditionally Approved by the CRDC committee. The conditions are as follows:

1) 6" high curbing must be provided in the areas between Westmoreland Avenue and Lots 1 and 8 and between Menlo Park Place and Lots 7 and 14,
2) "No Parking" signs must be places along the private street,
3) A ADA compliant sidewalk must be extended to Common Area B-2 next to lot 7.

If you have any additional questions, please contact me at 791-5608.

Sincerely,


Patricia Gehlen
Zoning/CDRC Manager
Development Services Department

Attachments: 1

XC: file
Records
Joe Comella, City of Tucson Community Services.