Review Details: RESUBMITTAL - DEVELOPMENT STANDARDS REVIEW
Permit Number - DS06-24
Review Name: RESUBMITTAL - DEVELOPMENT STANDARDS REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/28/2007 | MARILYN KALTHOFF | START | PLANS SUBMITTED | Completed | |
| 03/02/2007 | JOSE ORTIZ | COT NON-DSD | TRAFFIC | Approved | |
| 03/02/2007 | DAVID MANN | COT NON-DSD | FIRE | Approv-Cond | All homes in the subdivision must have automatic fire sprinklers. |
| 03/05/2007 | MATT FLICK | ENGINEERING | REVIEW | Denied | The DSD Engineering Division recommends denial of the DSMR to DS 3-01 to allow the narrower roadway. Although the applicant states that the request is for a 20' roadway, Detail A on the provided exhibit indicates a 16' wide roadway because of the presence of the parking space jutting into the street. This reduces the street width to 16'. The exhibit presented with the previous DSMR application showed a wider street section. Engineering would support the street width reduction if the pavement width remained at 20' and the on-street parking was eliminated. DSD Engineering has no objection to the 4' sidewalk and 34' turning radius. The DSD Engineering Division has no objection to granting of a DSMR to DS 3-01.2.4.D to allow parking which is not designed for both sides of the roadway. Ref: S05-252 |
| 03/07/2007 | ANDY VERA | ENV SVCS | REVIEW | Approved | * Access and turn around capability will work. * Curbside refuse collection for lots 3 thru 5 will be subject to ES approval. Alternative collection site may be required due to substandard cul-de-sac. |
| 03/09/2007 | ROGER HOWLETT | COT NON-DSD | URBAN PLANNING & DESIGN | Approv-Cond | DEPARTMENT OF URBAN PLANNING & DESIGN RESUBMITTAL Regarding SUBJECT: Development Standard Modification Request (DSMR) CASE NUMBER: CASE NAME: DATE SENT DS06-24 5020 E. Fort Lowell 03/09/07 ( ) Tentative Plat (XXXX) Development Plan ( ) Landscape Plan ( ) Revised Plan/Plat ( ) Board of Adjustment ( ) Other CROSS REFERENCE: S05-252 NEIGHBORHOOD PLAN: Old Ft. Lowell GATEWAY/SCENIC ROUTE: COMMENTS DUE BY 03/07/07 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: ( ) Proposal Complies with Annexation or Rezoning Conditions ( ) Proposal in Substantial Compliance with Plan Policies (XXXX) (XXXX) See Additional Comments Attached ( ) No Additional Comments - Complies With Planning Comments Submitted on: ( ) Resubmittal Required: ( ) Tentative Plat ( ) Development Plan ( ) Landscape Plan ( ) Other REVIEWER: drcorral 791-4505 DATE: 03/07/07 Department of Urban Planning and Design Comments: DS0-24 - 5020 E. Fort Lowell 03/07/07 (*NOTES*) Although staff will not be requiring a resubmittal, staff offers the following comments: Staff has a concern with the DSMR request to Development Standard 3-01.2.4-D. The proposal is for a total of two guest parking spaces for this five-lot subdivision. The applicant has stated that complying with this requirement would reduce the useable area within each proposed lot. Unavailability of adequate parking has been concern throughout the community. Staff recommends a site design modification that would allow for additional parking on-site, for approximately three more spaces. Private property cannot be used to satisfy guest parking requirements. |
| 03/09/2007 | DAVID RIVERA | ZONING | REVIEW | Approved | |
| 03/09/2007 | PGEHLEN1 | ZONING-DECISION LETTER | WRITE DECISION LETTER | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE CITY OF TUCSON - DEVELOPMENT SERVICES ***REVISED*** March 9, 2007 Stephen L. Calvert 5020 East Fort Lowell Tucson, Arizona 85712 Re: DSMR 06-24 - 5020 E Fort Lowell (S05-252) Request: DS 3-01.0.A - Several Modifications to street and turn around standards as shown on the final plat for S05-252 (20 foot road width, four (4) foot sidewalk, and a turn around radius of 34 feet to topr of wedge curb) DS 3-01.2.4.D - Modify street standards to eliminate required parking lanes The Development Standard Modification requested above to reduce the width of the street below 20 feet has been Denied by the CRDC committee. The remaining Development Standard Modification Requests (DSMRs) listed above have been Approved by the CDRC committee with the following conditions: 1) Approval of the WASH Overlay Application, 2) The proposed streets must be private, 3) All homes must have automatic fire sprinklers, 4) Provide four (4) guest parking spaces, 5) Curbside refuse collection for lots 3 thru 5 will be subject to ESD approval. If you have any additional questions, please contact me at 791-5608. Sincerely, Patricia Gehlen Zoning/CDRC Manager Development Services Department ttachments: 1 XC: file Records |