Permit Review Detail
Review Status: Completed
Review Details: DEV STDS MODIFICATION REVIEW
Permit Number - DS06-24
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/01/2006 | MARILYN KALTHOFF | START | PLANS SUBMITTED | Completed | |
| 06/02/2006 | MATT FLICK | ENGINEERING | REVIEW | Approv-Cond | Approved subject to WASH Ordinance overlay approval and street to be private, not public. |
| 06/06/2006 | JIM EGAN | FIRE | REVIEW | Approv-Cond | All homes in the subdivision must have automatic fire sprinklers. |
| 06/06/2006 | MKALTHO1 | COMMUNITY PLANNING | REVIEW | Approv-Cond | DEPARTMENT OF URBAN PLANNING & DESIGN Regarding SUBJECT: Development Standard Modification Request (DSMR) CASE NUMBER: CASE NAME: DATE SENT DS06-24 5020 E. Fort Lowell 06/06/06 ( ) Tentative Plat (XXXX) Development Plan ( ) Landscape Plan ( ) Revised Plan/Plat ( ) Board of Adjustment ( ) Other CROSS REFERENCE: S05-252 NEIGHBORHOOD PLAN: Old Ft. Lowell GATEWAY/SCENIC ROUTE: COMMENTS DUE BY 06/07/06 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: ( ) Proposal Complies with Annexation or Rezoning Conditions ( ) Proposal in Substantial Compliance with Plan Policies (XXXX) (XXXX) See Additional Comments Attached ( ) No Additional Comments - Complies With Planning Comments Submitted on: ( ) Resubmittal Required: ( ) Tentative Plat ( ) Development Plan ( ) Landscape Plan ( ) Other REVIEWER: D. Estolano 791-4505 DATE: 06/06/06 Department of Urban Planning and Design Comments: DS0-24 - 5020 E. Fort Lowell 06/06/06 (*NOTES*) Although staff will not be requiring a resubmittal, staff offers the following comments: Staff has a concern with the DSMR request to Development Standard 3-01.2.4-D. The proposal is for a total of two guest parking spaces for this five-lot subdivision. The applicant has stated that complying with this requirement would reduce the useable area within each proposed lot. Unavailability of adequate parking has been concern throughout the community. Staff recommends a site design modification that would allow for additional parking on-site, for approximately three more spaces. Private property cannot be used to satisfy guest parking requirements. |
| 06/06/2006 | JCLARK3 | ENV SVCS | REVIEW | Denied | * Refuse trucks cannot turnaround is the reduced size cul de sac. If there could be an 'L' type turnaround between lots 2 & 3 the trucks can operate safely within the development. |
| 06/08/2006 | DALE KELCH | TRAFFIC | TRAFFIC | Approved | From: Zelin Canchola To: Marilyn Kalthoff Date: 06/07/2006 8:28:14 AM Subject: DSMR DS06-24-5020 E Fort Lowell, S05-252 No objection Zelin Canchola Traffic Engineering |
| 06/09/2006 | DAVID RIVERA | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL FROM: David Rivera Principal Planner DSD Zoning Review Section PROJECT: DS06-124 5020 E Ft. Lowell Road Fort Lowell Place Subdivision - Final Plat Development Standard Modification Request Transmittal date: June 9, 2006 COMMENTS: Approved with conditions 1. A minimum of three visitor parking spaces must be provided. 2. Approval of the proposed roadway width by the Engineering, Environmental Services and Fire Department reviewing agencies. If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. |
| 06/23/2006 | PATRICIA GEHLEN | ZONING-DECISION LETTER | WRITE DECISION LETTER | Completed | COMMUNITY DESIGN REVIEW COMMITTEE CITY OF TUCSON - DEVELOPMENT SERVICES June 23, 2006 Stephen L. Calvert 1802 East 18th Street Tucson, Arizona 85719 Re: DSMR 06-24 - 5020 E Fort Lowell (S05-252) Request: DS 3-01 - Several Modifications to street and turn around standards as shown on the final plat for S05-252 DS 3-01.2.4.D - Modify street standards to eliminate required parking lanes The Development Standard Modification Request (DSMR) requested above to modify the turn around has been Denied by the CRDC committee. The remaining Development Standard Modification Requests (DSMRs) listed above have been Approved by the CDRC committee with the following conditions: 1) Approval of the WASH Overlay Application, 2) The proposed streets must be private, 3) All homes must have automatic fire sprinklers, 4) Provide three (3) guest parking spaces. If you have any additional questions, please contact me at 791-5608. Sincerely, Patricia Gehlen Zoning/CDRC Manager Development Services Department Attachments: 1 XC: file Records |