Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: DS06-05
Parcel: 107070080

Review Status: Completed

Review Details: DEV STDS MODIFICATION REVIEW

Permit Number - DS06-05
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/13/2006 MARILYN KALTHOFF START PLANS SUBMITTED Completed
02/13/2006 MATT FLICK ENGINEERING REVIEW Approved No objection to DSMR for a modification to DS 2-08.3.1 as it regards continuous circulation to new modular office.

Matt Flick
Engineering Manager
02/17/2006 JCLARK3 ENV SVCS REVIEW Approved
02/21/2006 DAVID RIVERA ZONING REVIEW Denied CDRC TRANSMITTAL

FROM: David Rivera
Principal Planner
DSD Zoning Review Section
PROJECT: DSMR-06-05
2640 N. Flowing Wells Road
Air Systems Components
Development Standard Modification Request

Transmittal date: February 21, 2006

COMMENTS: Zoning cannot support the DSMR request for the following reasons.

1. No modification is proposed to the development standard and is required when requesting a DSMR. In addition the sidewalk is to provide an accessible route which has not been addressed on the plan.

2. A DSMR cannot be used to eliminate a development standard. To eliminate the sidewalk completely requires a variance approval through the board of adjustments.





If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.
02/21/2006 JIM EGAN FIRE REVIEW Approv-Cond Maintain 20' wide, paved roads needed for Fire Department access.
02/22/2006 DALE KELCH TRAFFIC TRAFFIC Approved Traffic Engineering recommends APPROVAL of this DSMR.

D. Dale Kelch, PE
Senior Engineering Associate
Traffic Engineering Division
(520)791-4259x305
(520)791-5526 (fax)
dale.kelch@tucsonaz.gov
02/24/2006 MKALTHO1 COMMUNITY PLANNING REVIEW Approved DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Development Standard Modification Request (DSMR)

CASE NUMBER: CASE NAME: DATE SENT

DSMR 06-05 Air System Components 02/23/06

( ) Tentative Plat
( ) Development Plan
( ) Landscape Plan
( ) Revised Plan/Plat
( ) Board of Adjustment
(ü) Other - Site Plan

CROSS REFERENCE:

NEIGHBORHOOD PLAN: General Plan

GATEWAY/SCENIC ROUTE:

COMMENTS DUE BY: 2/21/06

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

( ) Proposal Complies with Annexation or Rezoning Conditions
( ) Proposal in Substantial Compliance with Plan Policies
( ) See Additional Comments Attached
(ü) No Additional Comments - Will Concur with Engineering Decision

( ) Resubmittal Required:
( ) Tentative Plat
( ) Development Plan
( ) Landscape Plan
( ) Other= DSMR Site Plan


REVIEWER: 791-4505 DATE: 1/26/2006
03/13/2006 PATRICIA GEHLEN ZONING-DECISION LETTER WRITE DECISION LETTER Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
CITY OF TUCSON - DEVELOPMENT SERVICES



March 13, 2006

Kim Acorn
Acorn Associates Architecture, Ltd.
4400 East Broadway Blvd., Suite 505
Tucson, Arizona 85711

Re: DSMR 06-05 2620 North Flowing Wells Road

Request: DS 2-08.3.1 - Modify on-site pedestrian circulation for new additions

The Development Standard Modification Request (DSMR) listed above has been approved with the following condition.

1) Continuous pedestrian from Flowing Wells to the new additions is not required. Continuous pedestrian circulation is required from the new parking spaces to the new additions.


If you have any additional questions, please contact me at 791-5608.

Sincerely,


Patricia Gehlen
Zoning/CDRC Manager
Development Services Department









Attachments: 1

XC: file
Records
Cory Lysdahl, Air Systems Components, L.P., 2620 North Flowing Wells Road, Tucson, Arizona, 85705