Permit Number: DS05-30
Parcel: 12907006U

Address:
1435 E 36TH ST

Review Status: Active

Review Details: DEV STDS MODIFICATION REVIEW

Permit Number - DS05-30
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
12/07/2005 ANY ZONING-DECISION LETTER WRITE DECISION LETTER Active
12/08/2005 MARILYN KALTHOFF START PLANS SUBMITTED Completed
12/08/2005 JIM EGAN FIRE REVIEW Approved The Fire Department has no objections, nor adverse comments, regarding DSMR 05-30.
12/13/2005 DAVID RIVERA ZONING REVIEW Approved CDRC TRANSMITTAL

FROM: David Rivera
Principal Planner
DSD Zoning Review Section
PROJECT: DSMR-05-30
Park Villa Casitas
Adult Residential Care Services Use
Development Standard Modification Request

Transmittal date: December 13, 2005

COMMENTS: Approved

1. Zoning supports the DSMR request based on the following findings.

a. The pedestrian circulation has been provided to the front doors of all units and connects both sides of the development with cross walks at four separate locations.

b. The sidewalks are designed as accessible routes with access ramps.

c. There is sufficient room between the buildings and the PAAL area to provide refuge for the occasional pedestrian not utilizing the sidewalks.

If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.
12/13/2005 JCLARK3 ENV SVCS REVIEW Approved
12/14/2005 MATT FLICK ENGINEERING REVIEW Approved No objection to the DSMR to DS 2-08.4.1.B to allow pedestrian circulation areas away from the PAAL.
12/16/2005 MKALTHO1 COMMUNITY PLANNING REVIEW Approved DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Development Standard Modification Request (DSMR)

CASE NUMBER: CASE NAME: DATE SENT

DSMR 05-30 1435 E. 36th Street 12/15/05

( ) Tentative Plat
( ) Development Plan
( ) Landscape Plan
( ) Revised Plan/Plat
( ) Board of Adjustment
(ΓΌ) Other - DSMR

CROSS REFERENCE:

NEIGHBORHOOD PLAN: Greater South Park

GATEWAY/SCENIC ROUTE:

COMMENTS DUE BY 12/14/05

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

( ) Proposal Complies with Annexation or Rezoning Conditions
( X ) Proposal in Substantial Compliance with Plan Policies
( ) See Additional Comments Attached
( ) No Additional Comments - Complies With Planning Comments Submitted on:

( ) Resubmittal Required:
( ) Tentative Plat
( ) Development Plan
( ) Landscape Plan
( ) Other

REVIEWER: D. Estolano 791-4505 DATE: 12/14/05
12/20/2005 DALE KELCH TRAFFIC TRAFFIC Approved Traffic Engineering recommends APPROVAL of this DSMR.

D. Dale Kelch, PE
Senior Engineering Associate
Traffic Engineering Division
(520)791-4259x305
(520)791-5526 (fax)