Review Date Reviewer's Name Type of Review Description Status Comments
07/05/2005 MARILYN KALTHOFF START PLANS SUBMITTED Completed
07/06/2005 JIM EGAN FIRE REVIEW Approv-Cond DSMR is approved with the condition that the Revised "Typical Cross Section-1" is submitted with the Revised Plat. No on-street parking is permitted. 20 feet travel lanes are TOTALLY unobstructed the complete 20 feet width.
07/11/2005 DALE KELCH TRAFFIC TRAFFIC Approved Traffic Engineering recommends APPROVAL of this DSMR.

D. Dale Kelch, PE
Senior Engineering Associate
Traffic Engineering Division
(520)791-4259x305
(520)791-5526 (fax)
dale.kelch@tucsonaz.gov
07/12/2005 JCLARK3 ENV SVCS REVIEW Approved
07/12/2005 MATT FLICK ENGINEERING REVIEW Approved Development Services Engineering does not object to the granting of the DSMR for DS 3-01. , Fig. 2 (as it relates to building setbacks) and DS 3-01.0, Fig. 24 (as it relates to the street jog distance from Morris Bl.).

If the site is reconconfigured from that shown on the exhibits included with the DSMR application, this approval will be void.

Matt Flick, PE
Engineering Manager
12JUL05
07/13/2005 MKALTHO1 COMMUNITY PLANNING REVIEW Approved DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Development Standard Modification Request (DSMR)

CASE NUMBER: CASE NAME: DATE SENT

DSMR 05-18 Placita Mariposa

(XXXX) Tentative Plat
( ) Development Plan
( ) Landscape Plan
( ) Revised Plan/Plat
( ) Board of Adjustment
( ) Other -

CROSS REFERENCE:

NEIGHBORHOOD PLAN: Kino Area Plan

GATEWAY/SCENIC ROUTE: No

COMMENTS DUE BY July 12, 2005

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

( ) Proposal Complies with Annexation or Rezoning Conditions
(XXXX) Proposal in Substantial Compliance with Plan Policies
( ) ( ) See the Additional Advisory Comments Attached
( ) No Additional Comments - Complies With Planning Comments Submitted on:








REVIEWER: DCE 791-4505 DATE: 7/11/05
07/14/2005 DAVID RIVERA ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

FROM: David Rivera
Senior Planner
DSD Zoning Review Section

PROJECT:


DSMR-05-18
Placita Mariposa
847-855 E. Drexel Road
Development Standard Modification Request Transmittal date:

July 14, 2005

COMMENTS: Zoning conditionally supports the requested DSMR.

1. DSMR 3-01.0 Figure 2 - Zoning will conditionally approve the cross section if the vertical curbs were constructed rather than the wedge curbs as depicted on the plan and if the Fire, Traffic Engineering and Environmental Services Departments approve the modification with 20 feet of travel lanes. (The wedge curbs invite on street parking even when "no-parking" signs are posted.)

(*** Zoning Comment: The proposed cross section does not allow sufficient area behind the sidewalk for utilities and a P.U.E. has not been provided over the individual lots due to the proposed type of development.)

2. DSMR 3-01.0 Figure 24 - conditionally approved if approved by Traffic Engineering.


If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.
08/02/2005 PATRICIA GEHLEN ZONING-DECISION LETTER WRITE DECISION LETTER Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
CITY OF TUCSON - DEVELOPMENT SERVICES
***REVISED****


August 2 2005 (Revised April 17, 2006)

George Holguin
ADC West, LLC
11,100 East Sundance Drive
Tucson, Arizona 85749

Re: DSMR 05-18 847 and 855 East Drexel - S04-166

Request: DS 3-01.0 - Figure 2 - modify cross section to eliminate two (2) foot shy space between curb and sidewalk and six (6) inch shy space between back of sidewalk and lot line,
DS3-01.0 - Figure 24 - reduce street jog to less than 150 feet.

The Development Standard Modification Requests (DSMR) listed above has been approved subject to the following conditions:

1. Revised plat is submitted for review by Fire Department. Revised plat must include revised cross section per comments from Fire Department (no on-street parking is permitted),
2. The tentative plat must be revised to show an easement for utilities.

If you have any additional questions, please contact me at 791-5608.

Sincerely,


Patricia Gehlen
Zoning/CDRC Manager
Development Services Department


Attachments: 1

XC: file
Records
Larry Potter, Southern Arizona Community Land Trust, Inc., P.O. Box 57370, Tucson, Arizona 85732