Permit Review Detail
Review Status: Completed
Review Details: DEV STDS MODIFICATION REVIEW
Permit Number - DS05-13
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/25/2005 | MARILYN KALTHOFF | START | PLANS SUBMITTED | Completed | |
| 05/25/2005 | MATT FLICK | ENGINEERING | REVIEW | Approved | The modification to DS 2-08.0 for 42" sidewalks in the areas shown on the exhibit is acceptable. Matt Flick Engineering Manager 25MAY05 |
| 05/26/2005 | JIM EGAN | FIRE | REVIEW | Approved | FIRE HAS NO OBJECTIONS NOR ADVERSE COMMENTS |
| 05/31/2005 | JCLARK3 | ENV SVCS | REVIEW | Approved | |
| 06/03/2005 | MKALTHO1 | COMMUNITY PLANNING | REVIEW | Denied | DEPARTMENT OF URBAN PLANNING & DESIGN Regarding SUBJECT: Development Standard Modification Request (DSMR) CASE NUMBER: CASE NAME: DATE SENT DSMR 05-13 The Exchange at Broadway ( ) Tentative Plat ( ) Development Plan ( ) Landscape Plan ( ) Revised Plan/Plat ( ) Board of Adjustment ( ) Other - Site Plan CROSS REFERENCE: NEIGHBORHOOD PLAN: Tumamoc GATEWAY/SCENIC ROUTE: COMMENTS DUE BY June 1, 2005 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: ( ) Proposal Complies with Annexation or Rezoning Conditions ( ) Proposal in Substantial Compliance with Plan Policies (XXXX) (*) See Additional Comments Attached ( ) No Additional Comments - Complies With Planning Comments Submitted on: ( ) Resubmittal Required: ( ) Tentative Plat ( ) Development Plan ( ) Landscape Plan () Other= DSMR Site Plan REVIEWER: DCE 791-4505 DATE: 6/1/05 Department of Urban Planning and Design Comments: DSMR 05-13 - The Exchange at Broadway June 1, 2005 Staff offers the following comments: The Tumamoc Area Plan (Plan), applicable policies: A. GENERAL PURPOSE: The purpose of the Tumamoc Area Plan is to guide future development while protecting and enhancing existing uses. One if the general purposes of the Plan is to: ยจ Provide safe and efficient circulation systems for all appropriate modes of transportation including pedestrian. The Development Standards states: 2-08.5.1A. Width. All sidewalks will be a minimum four (4) feet wide. 3-01.2.7A. Sidewalk Areas - Reduction in the width of the sidewalk area is not allowed, except when authorized by the City Engineer or designee under the following conditions. 1. If an alternative street cross-section has been previously approved; 2. In order to accommodate existing grade differentials; 3. In order to march existing sidewalks; 4. In order to accommodate drainage facilities. Based on the above, it does not appear that the applicant has provided sufficient justification for this development standard modification request. As designed, the project does not satisfy the "safe" and "efficient" circulation systems for pedestrians as set forth by the plans. Thus; the plans do not support relief from Development Standard 2-08.0. |
| 06/04/2005 | DAVID RIVERA | ZONING | REVIEW | Approved | CDRC TRANSMITTAL FROM: David Rivera Senior Planner DSD Zoning Review Section PROJECT: DSMR-05-13 The Exchange at Broadway Apartment Complex - Student Housing Development Standard Modification Request Transmittal date: June 4, 2005 COMMENTS: No Objection If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. |
| 06/06/2005 | DALE KELCH | TRAFFIC | TRAFFIC | Approved | Traffic Engineering recommends APPROVAL of this DSMR. D. Dale Kelch, PE Senior Engineering Associate Traffic Engineering Division (520)791-4259x305 (520)791-5526 (fax) dale.kelch@tucsonaz.gov |
| 06/07/2005 | PATRICIA GEHLEN | ZONING-DECISION LETTER | WRITE DECISION LETTER | Approved | COMMUNITY DESIGN REVIEW COMMITTEE CITY OF TUCSON - DEVELOPMENT SERVICES June 7, 2005 Tim Hicks. Fairfield Development 2045 North Highway 360, Suite 250B Grand Prairie, Texas 75050 Re: DSMR 05-13 2800 West Broadway - S04-146 - T03OT01130 Request: DS 2-08.5.1.A Allow some on-site sidewalks to be 42" instead of 48". The Development Standard Modification Request (DSMR) listed above has been approved without condition. If you have any additional questions, please contact me at 791-5608. Sincerely, Patricia Gehlen Zoning/CDRC Manager Development Services Department Attachments: 1 XC: file Records |