Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: DEV STDS MODIFICATION REVIEW
Permit Number - DS05-02
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/21/2005 | MARILYN KALTHOFF | START | PLANS SUBMITTED | Completed | |
| 01/25/2005 | JIM EGAN | FIRE | REVIEW | Approved | |
| 01/26/2005 | MATT FLICK | ENGINEERING | REVIEW | Approved | To allow wedge curbs on 56' right-of-way (1'-5' sidewalk-2' shy-2' wedge-36' pavement-2' wedge-2' shy-5' sidewalk-1') residential collectors. |
| 01/26/2005 | JCLARK3 | ENV SVCS | REVIEW | Approved | |
| 01/28/2005 | MKALTHO1 | COMMUNITY PLANNING | REVIEW | Approv-Cond | DEPARTMENT OF URBAN PLANNING & DESIGN Regarding SUBJECT: Development Standard Modification Request (DSMR) CASE NUMBER: CASE NAME: DATE SENT DSMR 05-02 Tres Pueblos 01/27/05 2215 East Bilby Road (Bilby Rd. btwn Campbell Ave. and Tucson Blvd.) (ü) Tentative Plat ( ) Development Plan ( ) Landscape Plan ( ) Revised Plan/Plat ( ) Board of Adjustment ( ) Other - Site Plan & Final Plat CROSS REFERENCE: S04-003 NEIGHBORHOOD PLAN: Kino Area Plan GATEWAY/SCENIC ROUTE: Tucson Blvd. (gateway route) COMMENTS DUE BY January 28, 2005 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: ( ) Proposal Complies with Annexation or Rezoning Conditions (ü) Proposal in Substantial Compliance with Plan Policies (ü) () See Additional Comments Attached ( ) No Additional Comments - Complies With Planning Comments Submitted on: Please have the applicant dimension the parking lanes and resulting travel lane widths on new street cross section REVIEWER: K. Aragonez 791-4505 DATE: 1/26/05 |
| 01/31/2005 | DAVID RIVERA | ZONING | REVIEW | Approved | |
| 02/01/2005 | DALE KELCH | TRAFFIC | TRAFFIC | Approved | Traffic Engineering recommends APPROVAL of this DSMR. D. Dale Kelch, EIT Senior Engineering Associate Traffic Engineering Division (520)791-4259x305 (520)791-5526 (fax) dale.kelch@tucsonaz.gov |
| 02/06/2005 | PATRICIA GEHLEN | ZONING-DECISION LETTER | WRITE DECISION LETTER | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE CITY OF TUCSON - DEVELOPMENT SERVICES February 6, 2005 James King Rick Engineering Company 1745 East River Road Suite 101 Tucson, AZ 85718 Re: DSMR 05-02 2215 E. Bilby Road S04-004 Request: DS 3-01.3.2.B.2.a - Allow wedge curb along proposed streets with an ADT > 1000. The Development Standard Modification Request (DSMR) as listed above has been approved by the Community Design Review Committee (CDRC) subject to the following conditions: 1. Dimension the parking and travel lanes on the new cross section on the tentative plat. If you have any additional questions, please contact me at 791-5608. Sincerely, Patricia Gehlen Zoning/CDRC Manager Development Services Department clg\c:\dsd\0304app.doc Attachments: 8 XC: file Records DR Horton Homes 5255 E. Broadway Blvd. Suite 1030, Tucson, Az., 85711 |