Permit Number: DS04-19
Parcel: Unknown

Address:
720 E LESTER ST

Review Status: Completed

Review Details: DEV STDS MODIFICATION REVIEW

Permit Number - DS04-19
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/29/2004 MARILYN KALTHOFF START PLANS SUBMITTED Completed
07/29/2004 JIM EGAN FIRE REVIEW Approved
07/30/2004 DAVID RIVERA ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

FROM: David Rivera
Senior Planner
DSD Zoning Review Section
PROJECT: DSMR-04-19
Hillcrest Apartments
720 E. Lester Street
Development Standard Modification Request
Transmittal date: July 30, 2004

COMMENTS: Zoning approves the DSMR with conditions. See the following comment.

1. Zoning does not object to the proposed location of the refuse container and the enclosure as long as the parking space, which abuts the refuse enclosure, is widened to ten feet.

Per D.S. 3-05.2.1.B.3
When the side(s) of a parking space abuts any vertical barrier over six (6) inches in height, other than a vertical support for a carport, the required width for the space is ten (10) feet to provide extra width to allow passengers to enter and exit the vehicle on the side where the barrier exists.

(The DSMR does not indicate a request to modify the width of the parking space to less than ten feet as required per the development standards.)

If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.
08/02/2004 MATT FLICK ENGINEERING REVIEW Approved No objection to DSMR for DS 6-01.4.1.I.
08/03/2004 MKALTHO1 ENV SVCS REVIEW Approv-Cond No objection. Approved for roll-out service.
Additional service charge required. Addition on site time for service. Service to be in Lester. Response ltr. to applicant sent.
08/03/2004 DALE KELCH TRAFFIC TRAFFIC Approv-Cond Traffic Engineering recommends APPROVAL of this DSMR contingent on approval of Environmental Services Department.

D. Dale Kelch, EIT
Senior Engineering Associate
Traffic Engineering Division
(520)791-4259x305
(520)791-5526 (fax)
dale.kelch@tucsonaz.gov
08/06/2004 MKALTHO1 COMMUNITY PLANNING REVIEW Approved DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Development Standard Modification Request (DSMR)

CASE NUMBER: CASE NAME: DATE SENT

DSMR 04-19 Hillcrest Apartments 08/06/04

( ) Tentative Plat
( ) Development Plan
( ) Landscape Plan
( ) Revised Plan/Plat
( ) Board of Adjustment
( ) Other - Architectural Site Plan

CROSS REFERENCE:

NEIGHBORHOOD PLAN: University

GATEWAY/SCENIC ROUTE:

COMMENTS DUE BY: 8/02/04

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

( ) Proposal Complies with Annexation or Rezoning Conditions
(XXXX) Proposal in Substantial Compliance with Plan Policies
( ) See Additional Comments Attached
( ) No Additional Comments - Complies With Planning Comments Submitted on:
( ) Resubmittal Required:
( ) Tentative Plat
( ) Development Plan
( ) Landscape Plan
( ) Other

REVIEWER: D. Estolano 791-4505 DATE: 8/02/04
08/09/2004 PATRICIA GEHLEN ZONING-DECISION LETTER WRITE DECISION LETTER Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
CITY OF TUCSON - DEVELOPMENT SERVICES

August 9, 2004

David V. Garcia, AIA
Architectural Design Group, Inc.
2510 E. Grant Road #140
Tucson, AZ 85716

Re: DSMR 04-19 - 720 E. Lester Street

Request: DS 6-01.4.1.I Collection vehicles may not back up into moving traffic


The Development Standard Modification Request (DSMR) listed above has been approved by the Community Design Review Committee (CDRC), subject to the following conditions:

1. The parking space south of the dumpster must be a minimum of 10 feet wide,
2. Garbage service is to be from Lester Street.


If you have any additional questions, please contact me at 791-5608.

Sincerely,


Patricia Gehlen
Zoning Manager
Development Services Department

clg\c:\dsd\0419app.doc

Attachments: 8
XC: file
Records
Tom Garcia & Steve Denny, Fortune Real Estate Services, LLC, 715 E. Lester Street, Tucson, Az, 85719