Permit Number: DS04-15
Parcel: 11105121B

Review Status: Completed

Review Details: DEV STDS MODIFICATION REVIEW

Permit Number - DS04-15
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/11/2004 MARILYN KALTHOFF START PLANS SUBMITTED Completed
06/15/2004 JIM EGAN FIRE REVIEW Approved
06/17/2004 MATT FLICK ENGINEERING REVIEW Approved Environmental Services has approved tentative plat showing hammerheads as depicted.
06/19/2004 DAVID RIVERA ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

FROM: David Rivera
Senior Planner
DSD Zoning Review Section
PROJECT: DSMR-04-15
Presidio Park Central
Tentative Plat - Residential Cluster Project
Development Standard Modification

Transmittal date: June 19, 2004

COMMENTS: Conditional Approval - See comments

1. Per the applicants response to the Zoning Reviewer's comment eight (8) dated March 25, 2004 all units will be barrier free accessible. Per the land use code 3.6.1.4.A.5 only 25% of the units must be barrier free accessible. If all the units are to be barrier free as stated in the applicant's response comments the plan must demonstrate how the units will be provided with the accessibility from the street and or a parking space. I do not believe that this requirement has been demonstrated on the drawing. In addition accessibility must be a concrete sidewalk not D.G. as proposed by the response comment to the Zoning Reviewers comment 13 dated March 25, 2004. If the number of accessible lots is reduced to the 25% (3 units) and the units selected are accessible from the street and or the parking space to the front door via concrete sidewalks and access ramps where required this comment can be disregarded.

2. I do not believe that a development standard modification can supersede a Land Use Code Requirement. Therefore I will make the following comment related to the Zoning Reviewers comment 13 dated March 25, 2004.

Per Land Use Code section 3.6.1.4.G.2 every RCP shall have a pedestrian circulation system connecting all elements of the RCP to all units. The system is to be physically separated from the vehicular circulation system, except where the system intersects a street. I do not believe the plan demonstrates that this requirement has been met but I also acknowledge that per DS 3-01.3.3.A, exceptions to the sidewalk requirements could be satisfied if the argument can be made under one of the exceptions and if this exception can supersede the Land Use Code requirement for the RCP.

I will leave this determination to Patricia Gehlen Principal Planner of the Zoning Review Section.
06/22/2004 DALE KELCH TRAFFIC TRAFFIC Approved
07/02/2004 PGEHLEN1 COMMUNITY PLANNING REVIEW Approved
07/02/2004 PGEHLEN1 ENV SVCS REVIEW Approved
07/02/2004 PATRICIA GEHLEN ZONING-DECISION LETTER WRITE DECISION LETTER Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
CITY OF TUCSON - DEVELOPMENT SERVICES


July 2, 2004

Jeff Stine
AMEC Infrastructure, Inc.
3295 West Ina Road, Suite 200
Tucson, AZ 85741

Re: DSMR 04-15 - 3226 East Presidio Road


Request: DS 3-01.6.5.D Private street does not have to meet all Public street standards
DS 3-01.6.2.C.2 Reduce width of T turn around from 24' to 20'

The Development Standard Modification Requests (DSMR) as listed above have been approved by the Community Design Review Committee (CDRC), subject to the following conditions:

1. Demonstrate that units places on lots 3, 4, 9, and 10 meet the barrier free accessibility requirements per LUC 3.6.1.4.A.5,
2. All driveways must be concrete per DS 3-01.3.3.A.4.

If you have any additional questions, please contact me at 791-5608.

Sincerely,


Patricia Gehlen
Principal Planner
Development Services Department

clg\c:\dsd\0415app.doc