Permit Review Detail
Review Status: Active
Review Details: DEV PKG
Permit Number - DP22-0277
Review Name: DEV PKG
Review Status: Active
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
10/12/2022 | ANY | ENGINEERING | REVIEW | Active | |
10/12/2022 | ANY | LANDSCAPE | REVIEW | Active | |
10/12/2022 | ANY | PLUMBING-COMMERCIAL | REVIEW | Active | |
10/12/2022 | ANY | COT NON-DSD | FIRE | Active | |
10/12/2022 | ANY | COT NON-DSD | REVIEW | Active | |
10/12/2022 | ANY | ZONING-DECISION LETTER | REVIEW | Active | |
10/12/2022 | ANY | PIMA COUNTY - ADDRESSING | PIMA COUNTY - ADDRESSING | Active | |
10/12/2022 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
10/20/2022 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: Casino Self Storage Development Package (1st Review) DP22-0277 TRANSMITTAL DATE: October 20, 2022 DUE DATE: October 26, 2022 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is October 02, 2023. CONTENT REQUIREMENTS 1. COMMENT: 2-06.4.3 – Provide the development package case number, DP22-0277, adjacent to the title block on all sheets. 2-06.4.7 - General Notes The following general notes are required. Additional notes specific to each plan are required where applicable. 2-06.4.7.A - Zoning and Land Use Notes 2. COMMENT: 2-06.4.7.A.4 – The Use Specific Standards listed under General Note 5 are not correct. Review UDC TABLE 4.8-5 and provide the correct standards. 3. COMMENT: 2-06.4.7.A.6.a – As modifications, IPP, TSMR, are proposed, once approved provide the case number(s) adjacent to the title block and complete the general notes to include the case numbers, date of approval, what was modified, and if applicable conditions of approval. 2-06.4.8 - Existing Site Conditions The following information shall be provided on the plan/plat drawing to indicate the existing conditions on site and within 50 feet of the site. On sites bounded by a street with a width of 50 feet or greater, the existing conditions across the street will be provided. 4. COMMENT: 2-06.4.8.C - The following information regarding existing private or public right-of-way adjacent to or within the site shall be provided: the name, right-of-way width, recordation data, type and dimensioned width of paving, curbs, curb cuts, and sidewalks. 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. 5. COMMENT: 2-06.4.9.H.5.a - Until the IPP is approved and required information provided Zoning cannot approve this DP. 6. COMMENT: 2-06.4.9.H.5.a – Provide a detail for both a standard and accessible vehicle parking space. The details shall provide the space, width & depth and wheel stop location and the access aisle width for the required accessible space. 7. COMMENT: 2-06.4.9.H.5.d – Demonstrate how the requirements of UDC Article 7.4.9.B.1.e are met. 8. COMMENT: 2-06.4.9.O – Provide a setback dimension from the proposed building to the curb along the frontage road of I-10. Minimum setback is 21’ or the height of the building wall, greater of the 2. A Board of Adjustment for Variance maybe required. 9. COMMENT: 2-06.4.9.R – A Technical Standards Modification Request (TSME) will need to be submitted and approved for the proposed 3.1’ sidewalk shown on the plan. 10. COMMENT: 2-06.4.9.R – Provide sidewalk width dimensions for the sidewalk shown along the west side of the building. 11. COMMENT: 2-06.4.9.W - Indicate the locations and types of proposed signs (wall, free-standing, pedestal) to assure there are no conflicts with other requirements and that minimal locational requirements can be met. 12. COMMENT: Provide a detail for the proposed security fence called out under Keynote 42 so that perimeter yard setback requirements can be verified. If you have any questions about this transmittal, please contact Nicholas Ross at Nicholas.Ross@tucsonaz.gov. To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
10/20/2022 | DSTIFFE1 | COT NON-DSD | TRAFFIC | Reqs Change | DP22-0277 Comments: 1. The existing curb, sidewalk and the driveway apron may remain if they are within current standards. 2. Any existing curb, sidewalk, curb access ramps or driveway aprons which are not compliant with current standards will be modified or replaced to meet current standards. 3. Concrete curb per P.A.G. standard 209. 4. Concrete sidewalk per P.A.G. standard 200. 5. Concrete curb access ramp per P.A.G. standard 207. 6. At least one sidewalk is required to connect the onsite circulation path to sidewalk in the ROW. 7. New driveway apron per P.A.G. standard 206. 8. Sidewalk from the onsite circulation path cannot tie directly into a driveway apron. 9. For further questions contact an inspector for an onsite precon. 520-791-5100 David Stiffey 520-403-0970 DTM Project Coordinator David.Stiffey@tucsonaz.gov |