Permit Number: DP22-0275
Parcel: 12705075A

Review Status: Completed

Review Details: DEV PKG - OK TO SUBMIT

Permit Number - DP22-0275
Review Name: DEV PKG - OK TO SUBMIT
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/03/2022 SBEASLE1 START PLANS SUBMITTED Completed
10/04/2022 NMARTEL1 ZONING REVIEW Denied Please re-submit the Development Package as one document.

Ensure the submittal requirements are addressed on the next submittal, as found here: https://www.tucsonaz.gov/files/pdsd/forms/Submittal_Requirements.pdf

including:

a. Existing site conditions
b. Right of way information
c. Compliant project location map
d. Sheet Index
e. Consistent title block


nicholas.martell@tucsonaz.gov
10/04/2022 LEVANS2 ENGINEERING REVIEW Reqs Change 1. The dumpster enclosure must have a minimum 10-foot by 10-foot interior space per TSM 8-01.5.2 C, provided dumpster plan shows the total width of the dumpster enclosure as 9 feet.
2. The dumpster enclosure must have a minimum unobstructed opening of 12 feet at the gate per TSM 8-01.5.2 F, provided dumpster detail shows the gate opening is 10 feet 2 inches.
3. Ensure that the concrete apron in the dumpster enclosure detail is sloped at least 2% away from the enclosure to comply with TSM 8-01.5.2 G.

Lianne Evans
lianne.evans@tucsonaz.gov
10/06/2022 SBEASLE1 ZONING-DECISION LETTER WRITE DECISION LETTER Completed email from: COTDSDPermits
TO: Chavonne Jennings
10/06/2022

Plan Denied for Review / Request for Resubmittal
See the Zoning review comments on PRO.

NOTE: Please follow the steps below to resubmit your documents for review

Permit/Activity Number: DP22-0275

Project Description:
Site - Pizza Hut restaurant. New dumpster enclosure, fence repair, reseal and re-stripe parking.
4710 E SPEEDWAY BL

PRO
To view the "Dev Pkg - Okay to Submit" comments by Reviewers and your documents:
www.tucsonaz.gov/pro
1. Home page, left side - Activity Search
2. Enter the Activity Number (it’s not case-sensitive)
3. Under "Permits" heading, click on blue tab and you will see different sections
4. Reviews section - click on Review Details
5. Documents section - click on View to the right of each document

YOUR NEXT STEPS
After corrections are made, name your documents again as a first submittal (the number one leads the title), for example: 1_Dev Pkg Application

Upload ALL documents to the Filedrop.
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
- Select "Existing Application"
- In the "Permit Number" field, enter the number and if applicable, any notes for our staff