Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: DEV PKG
Permit Number - DP22-0183
Review Name: DEV PKG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/18/2022 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 07/18/2022 | SBEASLE1 | ENGINEERING | REVIEW | Approved | Engineering was approved by Loren Makus during the OK to Submit. |
| 07/26/2022 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: El Rio – El Pueblo Health Center Building Addition Development Package (1st Review) DP22-0183 TRANSMITTAL DATE: July 26, 2022 DUE DATE: August 01, 2022 COMMENTS: Resubmit revised drawings and a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is July 06, 2023. CONTENT REQUIREMENTS 1. COMMENT: 2-06.4.1 – Provide the mailing and email addresses, and phone number of the primary property owner. 2. COMMENT: 2-06.4.3 – Provide the development package case number, DP22-0183, adjacent to the title block on all sheets. 2-06.4.7 - General Notes The following general notes are required. Additional notes specific to each plan are required where applicable. 2-06.4.7.A - Zoning and Land Use Notes 3. COMMENT: 2-06.4.7.A.2 - List the gross area of the site/subdivision by square footage and acreage. 4. COMMENT: 2-06.4.7.A.4 – Review UDC Tables 4.8-3 & 4.8-4 and provide the applicable Use Specific Standards for the Medical Service Outpatient use. 5. COMMENT: 2-06.4.7.A.6.a – As Nogales Hwy is designated as and Arterial on the COT MS&R Map provide a general note stating “THIS PROJECT IS DESIGNED TO MEET THE OVERLAY ZONE(S) CRITERIA, UDC ARTICLE 5.4 MAJOR STREETS AND ROUTES SETBACK ZONE (MS&R)”. 2-06.4.7.A.8 - For development package documents provide: 6. COMMENT: 2-06.4.7.A.8.c – Provide a building area expansion calculation on the plan. 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. 7. COMMENT: 2-06.4.9.H.5.d – The bicycle parking calculation should be based on the total square footage 27,792. 8. COMMENT: 2-06.4.9.H.5.d – The number of required long-term bicycle parking spaces is not correct and should be 2, see UDC Article 7.4.3.G. If you have any questions about this transmittal, please contact Nicholas Ross at Nicholas.Ross@tucsonaz.gov. To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 08/03/2022 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 08/09/2022 | AWARNER1 | LANDSCAPE | REVIEW | Needs Review | Provide expansion calculations, UDC 7.6.2.B |
| 08/22/2022 | JPEELDA1 | FIRE | REVIEW | Approved | |
| 08/29/2022 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | Email from: COTDSDPermits to: lisa bowers 08/29/2022 REVIEW NOTICE Returned for Corrections: DP22-0183 Site: El Rio-El Pueblo Health Center. Building addition / infill under second story roof. (The Owner is City of Tucson) Fee Balance: $0 (zero) YOUR NEXT STEPS 1. SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on blue tab - Reviews section - click on REVIEW DETAILS - Documents section - click on VIEW 2. Title your SECOND submittal documents accordingly, example: 2_Comment Response Letter 3. UPLOAD documents to Filedrop: - Comment Response Letter (your response to REQUIRES CHANGE comments) - Plan Set (all pages, full set, even if no changes were made) - Documents requested by review staff FILEDROP https://docs.tucsonaz.gov/Forms/tucsonpermitapp - "Existing Application" - "Permit Number" field: enter the number (and any notes for our staff) Sharon Beasley, Certified Permit Technician City of Tucson, Planning & Development Services Dept. Email: COTDSDpermits@TucsonAz.gov (for development packages, land splits, Thursday Presubmittal meetings) Email: PDSDinquiries@TucsonAz.gov (for building permits) |