| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/15/2022 | AWARNER1 | NPPO | REVIEW | Approved | |
| 07/15/2022 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 08/15/2022 | SBLOOD1 | ENGINEERING | REVIEW | Reqs Change | Development Package Comments: Sheet 1 1. Provide a 3" x 5" block in the lower right corner of the plan adjacent to the title block for use by Pima County Addressing. 2. Please see UDC AM 2-06.3.0 and -4.0 for cover sheet format and content requirements. Project location map is to be in the upper right corner and drawn at a scale of 3"=1 mile. Show the subject property approximately centered within the map and call out as "This Project". 3. Provide a key plan. Sheet 6 4. Revise the stationing listed on the cross sections to match the plan view. 5. Please review cross sections. All cross sections should be mirrored to match plan view. Sheet 10 6. Please add call out specifying materials in slope protection typical section detail. Sheet 13 7. Please provide a list of the keynotes that are in a rectangle. 8. Show stationing in plan view. 9. Please depict culvert with invert in profile view (STA 258+64). 10. Please depict existing waterline in profile 11. Please label outlet invert. 12. Please depict curb openings in profile. Sheet 14 13. Please confirm that the stationing on plan view and on the profile match. 14. Please call out station of low point in profile. 15. Please evaluate the need for concrete header where discharge exits roadway. Sheet 18 16. Please show stationing. Sheet 26 17. Please identify where included stormwater quality protection & erosion/sediment control details are proposed (ex: gravel bag protection, check dam, stabilized construction entrance). Drainage Report Comments: 1. Exhibit A - Provide contour elevations on drainage map. 2. Exhibit A - Provide culvert hydraulic data on drainage map. 3. Exhibit A - Culvert alignment on drainage map does not match roadway plans. 4. Exhibit A - Exhibit A reports the basin area as 10.45 ac which is the "with Project Penny" area, but the basin limits are "without Project Penny". Reconcile basin areas and drawn limits. Does the Project Penny basin need to be shown? What is the purpose of calculation the with and without discharge? Please clarify which assumption is used as the basis of design. 5. Sheet 13 of 30 - Confirm adequate cover over culverts to be constructed "by other" as part of Project Penny. 6. Exhibit A - Need to address the pavement drainage area east of Aero2 and potential erosion where flow discharges at end of curb and gutter down the fill slope. 7. Sheet 13 of 30 - Need more detail for CU2 inlet grading and protection. It is set about 4 feet below adjacent grade. Need to ensure head cutting does not occur. Review and Comments provided by third party engineer reviewers under contract with the City of Tucson. For Questions or Concerns contact: Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |
| 08/18/2022 | DSTIFFE1 | COT NON-DSD | TRAFFIC | Reqs Change | DP22-0169 Comments: 1. This project is going to require a PIA. https://www.tucsonaz.gov/tdot/private-improvement-agreement David Stiffey DTM Project Coordinator David.Stiffey@tucsonaz.gov |
| 08/19/2022 | SBEASLE1 | ZONING-DECISION LETTER | WRITE DECISION LETTER | Reqs Change | Email from: COTDSDPermits To: Victor Palma cc: Drew Spear, Ian Mowry REVIEW NOTICE Returned for Corrections: DP22-0169 Grading/Swppp - Tucson Airport Authority, Project Penny Aeronautical Way Improvements. New roadway and drainage improvements to extend Aeronautical Way 1,200' in front of new development for the Tucson Airport Authority. 3615 E AERONAUTICAL WY FEE BALANCE: $ 26,002.95 See image at end of email - the majority is for the grading review (completed by engineers Loren Makus and Stephen Blood) Please pay at a minimum, the REVIEW category fees. A payment is required before your next submittal. ONLINE PAYMENTS ** If the online amount doesn't match "Fee Balance" shown above, check back in a few hours ** https://www.tucsonaz.gov/pdsd/fees 1- Click on: Pay Planning & Permit Fees 2- Enter Permit Nbr, example: dp20-0000 (not case-sensitive but a hyphen-dash- is needed) 3- Business/Individual Name: Leave this field blank 4- "Continue" 5- In the Pay column - check the boxes 6- "Continue" YOUR NEXT STEPS 1. SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on blue tab - Reviews section - click on REVIEW DETAILS - Documents section - click on VIEW 2. Title your SECOND submittal documents accordingly, example: 2_Comment Response Letter 3. UPLOAD A RESUBMITTAL to Filedrop: - Comment Response Letter (your response to REQUIRES CHANGE comments) - Plan Set (all pages, full set, even if no changes were made) - Any other documents requested by review staff FILEDROP https://docs.tucsonaz.gov/Forms/tucsonpermitapp - "Existing Application" - "Permit Number" field: enter the number (and any notes for our staff) - Select "PLANS" for all documents Sharon Beasley, Certified Permit Technician City of Tucson, Planning & Development Services Dept. Email: COTDSDpermits@TucsonAz.gov (for development packages, land splits, Thursday Presubmittal meetings) Email: PDSDinquiries@TucsonAz.gov (for building permits) |