Permit Number: DP22-0159
Parcel: 11307088B

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP22-0159
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/22/2022 SBEASLE1 START PLANS SUBMITTED Completed
07/08/2022 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: Pastiche Outdoor Dining
Development Package (1st Review)
DP22-0159

TRANSMITTAL DATE: July 8, 2022

DUE DATE: July 12, 2022

COMMENTS: Resubmit revised drawings and a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is June 09, 2023.

2-06.2.0 APPLICATION SUBMITTAL REQUIREMENTS

1. COMMENT: 2-06.2.4 – As the DP is for site related reviews only remove all references to Building Code from the plans

2-06.3.0 FORMAT REQUIREMENTS

2. COMMENT: 2-06.3.2 – All mapped data shall be drawn at an engineering scale having no more than 50 feet to the inch. Revised sheets 4 & 5 to meet this requirement.

CONTENT REQUIREMENTS

3. COMMENT: 2-06.4.1 – Provide the name, mailing and email addresses, and phone number of the primary property owner of the site, on the right half of the cover sheet.

4. COMMENT: 2-06.4.2.D – Provide the page number and the total number of pages in the package (i.e., sheet xx of xx) on all sheets of the DP.
5.

6. COMMENT: 2-06.4.3 – Provide the development package case number, DP22-0159, adjacent to the title block on all sheets.

7. COMMENT: 2-06.4.4 - The project-location map shall be drawn at a minimum scale of three-inch equals one mile.

8. COMMENT: 2-06.4.4.C – Label the ection, township, and range; section corners and the scale on the location map.

2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

2-06.4.7.A - Zoning and Land Use Notes

9. COMMENT: 2-06.4.7.A.2 - List the gross area of the site/subdivision by square footage and acreage.

10. COMMENT: 2-06.4.7.A.4 – The existing and proposed use should be Food Service Excluding Soup Kitchens. subject to Use Specific Standards 4.9.4.M.1 & 5 and 4.9.13.O.

11. COMMENT: 2-06.4.7.A.6.a - As Campbell Ave is designated as an Arterial Gateway on the COT MS&R map provide a general note stating “THIS PROJECT IS DESIGNED TO MEET THE OVERLAY ZONE(S) CRITERIA, UDC ARTICLE 5.4 MAJOR STREETS AND ROUTES SETBACK ZONE (MS&R) & UDC ARTICLE 5.5 GATEWAY CORRIFOR ZONE (GCR)”

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

12. COMMENT: 2-06.4.9.H.5.a – As you are proposing and expansion to a food service and the vehicle parking is based on 1 space per 100 sq ft of GFA clearly demonstrate that the requirements of a shopping center, no more than 50% of the floor area is dedicated to uses with a parking formula of one space per 100 square feet of gross floor area or a more intense formula are met.

13. COMMENT: 2-06.4.9.H.5.a – The mounting height shown on the HC Parking Sign detail is not correct and should be to the lowest part of the sign. Mounting height should be shown as 7’-0” within a pedestrian circulation path and 5’-0” when not within a pedestrian circulation path.

If you have any questions about this transmittal, please contact Nicholas Ross at Nicholas.Ross@tucsonaz.gov.

To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
07/28/2022 AWARNER1 LANDSCAPE REVIEW Approved
08/08/2022 JPEELDA1 FIRE REVIEW Approved
08/15/2022 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change Email from: COTDSDPermits
To: Bernard Buford
08/15/2022


REVIEW NOTICE

Returned for Corrections: DP22-0159
Site: Pastiche Outdoor Dining, Suite # 121. New dining area, concrete sidewalk and slab work, new fencing, and new ADA parking spaces with new curb access ramp.
3025 N CAMPBELL AV

Fee Balance: $0 (zero) Thank you for the payment.

YOUR NEXT STEPS
1. SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW

2. Title your SECOND submittal documents accordingly, example: 2_Comment Response Letter

3. UPLOAD A RESUBMITTAL to Filedrop:
- Comment Response Letter (your response to REQUIRES CHANGE comments)
- Plan Set (all pages, full set, even if no changes were made)
- Any other documents requested by review staff

FILEDROP
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
- "Existing Application"
- "Permit Number" field: enter the number (and any notes for our staff)
- Select "PLANS" for all documents


Sharon Beasley, Certified Permit Technician

City of Tucson, Planning & Development Services Dept.
Email: COTDSDpermits@TucsonAz.gov
(for development packages, land splits, Thursday Presubmittal meetings)
Email: PDSDinquiries@TucsonAz.gov
(for building permits)