Permit Number: DP22-0150
Parcel: 134244300

Address:
6363 E 22ND ST

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP22-0150
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/21/2022 SBEASLE1 START PLANS SUBMITTED Completed
06/21/2022 SBEASLE1 ENGINEERING REVIEW Approved Engineering was approved by Loren Makus during the OK to Submit.
06/28/2022 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
06/30/2022 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: Cal Ranch Retail Store
Development Package (1st Review)
DP22-0150

TRANSMITTAL DATE: June 30, 2022

DUE DATE: July 01, 2022

COMMENTS: Resubmit revised drawings and a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is June 07, 2023.

CONTENT REQUIREMENTS

1. COMMENT: 2-06.4.1 – Provide an email address for the Owner listed on sheet 1.

2. COMMENT: 2-06.4.3 – Provide the development package case number, DP22-0150, adjacent to the title block on all sheets.

3. COMMENT: 2-06.4.4.C – The section corners listed on the location map are not correct. Also, remove the subdivisions from the location map as they are not required.

2-06.4.7.A.8 - For development package documents provide:

4. COMMENT: 2-06.4.7.A.8.d – As this site is part of a larger site, the calculations encompass the entire site, whether existing or proposed.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

5. COMMENT: 2-06.4.9.H.5.a – The vehicle parking space calculation is not correct and shall include the entire shopping center, reference T09CM02651. Also, per UDC Article 7.4.3.F.4 outdoor areas used for sale of merchandise shall be included in the required number of vehicle parking spaces.

6. COMMENT: 2-06.4.9.H.5.a – Clearly show that the vehicle parking spaces directly north of the proposed fence called out under Keynote 3 meet the requirements of UDC Article 7.4.6.D.b.

7. COMMENT: 2-06.4.9.H.5.a - Clearly show how the requirements of UDC Article 7.4.6.H.1 are met for the vehicle parking spaces along the east and west sides of the proposed “OUTDOOR SALES AREA”.

If you have any questions about this transmittal, please contact Nicholas Ross at Nicholas.Ross@tucsonaz.gov.

To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
07/11/2022 AWARNER1 LANDSCAPE REVIEW Approved
07/14/2022 JPEELDA1 FIRE REVIEW Approved
07/15/2022 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change email from: COTDSDPermits
To: Tri Miller
Fri 7/15/2022 10:52 AM

REVIEW NOTICE

Returned for Corrections: DP22-0150
SITE - Cal Ranch Retail Store. Building remodel.
6363 E 22ND ST

FEE BALANCE: $ 511.50
Please pay at a minimum, the REVIEW category fees.
A payment is required before your next submittal.

ONLINE PAYMENTS
** If the online amount doesn't match "Fee Balance" shown above, check back in a few hours **
https://www.tucsonaz.gov/pdsd/fees
1- Click on: Pay Planning & Permit Fees
2- Enter Permit Nbr, example: dp20-0000
(not case-sensitive but a hyphen-dash- is needed)
3- Business/Individual Name: Leave this field blank
4- "Continue"
5- In the Pay column - check the boxes
6- "Continue"

YOUR NEXT STEPS
1. SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW

2. Title your SECOND submittal documents accordingly, example: 2_Comment Response Letter

3. UPLOAD A RESUBMITTAL to Filedrop:
- Comment Response Letter (your response to REQUIRES CHANGE comments)
- Plan Set (all pages, full set, even if no changes were made)
- Any other documents requested by review staff

FILEDROP
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
- "Existing Application"
- "Permit Number" field: enter the number (and any notes for our staff)
- Select "PLANS" for all documents


Sharon Beasley, Certified Permit Technician

City of Tucson, Planning & Development Services Dept.
Email: COTDSDpermits@TucsonAz.gov
(for development packages, land splits, Thursday Presubmittal meetings)
Email: PDSDinquiries@TucsonAz.gov
(for building permits)