Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP22-0114
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/22/2022 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 09/07/2022 | PAUL CAMARENA | ZONING | REVIEW | Reqs Change | FROM: Paul Camarena PDSD Zoning Review Section PROJECT: Crossroads Festival PAD Development Package (2nd Review) DP22-0114 TRANSMITTAL DATE: September 7, 2022 DUE DATE: September 14, 2022 COMMENTS: Resubmit revised drawings and a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is May 03, 2023. This comment is still applicable, please show a continuous pedestrian circulation path to the existing buildings on site 8. COMMENT: 2-06.4.9.R – Per TSM 7-01.3.3.B & 7-01.4.1.D a pedestrian circulation/sidewalk is required to connect the proposed buildings to the existing buildings on site, clearly demonstrate how this is accomplished. A virtual meeting is recommended. ***For additional information on the any standard presented in this memo, please refer to the City of Tucson “Unified Development Code” – Administrative Manual Section 2-06 or Technical Standards noted in the comments. https://www.tucsonaz.gov/pdsd/all-codes-plans-determinations If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov |
| 09/07/2022 | SBLOOD1 | ENGINEERING | REVIEW | Approved | |
| 09/13/2022 | DSTIFFE1 | COT NON-DSD | TRAFFIC | Reqs Change | DP22-0114 Comments: 1. Any existing curb, sidewalk or Curb Access Ramps adjacent to Grant Rd, along the frontage of the property, are to be brought up to current standards. 2. Sheet 3- Regarding the new "Pedestrian Path" sidewalk, tying into sidewalk in the City ROW, at the two locations where the sidewalk turns at a 90°, these two turns are to be ADA "Landings." Landings are to be a minimum of 60" X 60" and not to exceed 2% in any direction. a. Please provide "spot grades" for the corners of the landings. It appears as though the east/ west slope is 3.8% The landing cannot exceed 2% in cross-slope in any direction. b. Please note the DISTANCE between the two 90° landings. 3. At the point where new pedestrian path/ sidewalk ties-in to the "existing" sidewalk adjacent to Grant Rd, this tie-in also must meet the criteria of an ADA Landing. The "Landing" must be where the existing sidewalk is. (The existing will need to be removed and replaced at 60" Square. David Stiffey DTM Project Coordinator David.Stiffey@tucsonaz.gov |
| 09/22/2022 | AWARNER1 | LANDSCAPE | REVIEW | Approved | |
| 09/26/2022 | JPEELDA1 | COT NON-DSD | FIRE | Approved | |
| 09/28/2022 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | email from: COTDSDPermits To: Marty Magelli cc: Jean REVIEW NOTICE Returned for Corrections: DP22-0114 Site/Grading - Crossroads Festival PAD, new Chipotle restaurant. 4857 E GRANT RD Fee Balance: $0 (zero) Thank you for the payment. YOUR NEXT STEPS 1. SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on the blue tab - Reviews section - click on REVIEW DETAILS - Documents section - click on VIEW 2. Title your THIRD submittal documents accordingly, example: 3_Comment Response Letter 3. UPLOAD documents to Filedrop: - Comment Response Letter (your response to REQUIRES CHANGE comments) - Plan Set (all pages, full set, even if no changes were made) - Documents requested by review staff FILEDROP https://docs.tucsonaz.gov/Forms/tucsonpermitapp - "Existing Application" - "Permit Number" field: enter the number (and any notes for our staff) Sharon Beasley, Certified Permit Specialist City of Tucson, Planning & Development Services Dept. Email: COTDSDpermits@TucsonAz.gov (for development packages, land splits, Thursday Presubmittal meetings) Email: PDSDinquiries@TucsonAz.gov (for building permits) |