Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: DP22-0089
Parcel: 14039052E

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP22-0089
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/21/2022 SBEASLE1 START PLANS SUBMITTED Completed
04/21/2022 SBEASLE1 ENGINEERING REVIEW Reqs Change Review comments from the OK to Submit:

1. Add a note indicating review by Environmental Services is required since the project is within 500 feet of a landfill. (TC Sec 29-24)
2. Show slopes on new and existing slopes for sidewalks.

Loren Makus
loren.makus@tucsonaz.gov
04/22/2022 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: Los Reales Landfill – New Canopy
Development Package (1st Review)
DP22-0089

TRANSMITTAL DATE: April 22, 2022

DUE DATE: May 05, 2022

COMMENTS: Please resubmit revised drawings and a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is April 20, 2023.

CONTENT REQUIREMENTS

1. COMMENT: 2-06.4.2.A – Remove the reference to “LOTS X-XX & COMMON AREAS”X”, “X” & “X”” as this is not a tentative plat.

2. COMMENT: 2-06.4.3 – Provide the development package case number, DP22-0089, adjacent to the title block on all sheets.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

3. COMMENT: 2-06.4.9.Q – Provide the height and square footage of the canopy within the foot print.

If you have any questions about this transmittal, please contact Nicholas Ross at Nocholas.Ross@tucsonaz.gov.

To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
04/29/2022 JVINCEN1 FIRE REVIEW Approved
05/02/2022 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
05/13/2022 AWARNER1 LANDSCAPE REVIEW Approved
05/19/2022 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change Email from: COTDSDPermits
to: lisa bowers
Thu 5/19/2022 10:53 AM

REVIEW NOTICE
Returned for Corrections: DP22-0089

DESCRIPTION: Site/Grading - Los Reales Landfill. Canopy.

Fee Balance: $0 (zero)

YOUR NEXT STEPS
1. SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW

2. Title your SECOND submittal documents accordingly, example: 2_Comment Response Letter

3. UPLOAD A RESUBMITTAL to Filedrop:
- Comment Response Letter (your response to REQUIRES CHANGE comments)
- Plan Set (all pages, full set, even if no changes were made)
- Any other documents requested by review staff

- FILEDROP:
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
- "Existing Application"
- "Permit Number" field: enter the number (and any notes for our staff)
- Select "PLANS" for all documents


Sharon Beasley, Certified Building Technician

City of Tucson, Planning & Development Services Dept.
Email: COTDSDpermits@TucsonAz.gov
(for development packages, land splits, Thursday Presubmittal meetings)

Email: PDSDinquiries@TucsonAz.gov
(for building permits and all other subjects)