Permit Number: DP22-0084
Parcel: 141366870

Review Status: Completed

Review Details: GRADING

Permit Number - DP22-0084
Review Name: GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/20/2022 STEVE SHIELDS ZONING REVIEW Approv-Cond PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: La Estancia Parcel 8 – Grading Only
Development Package (1st Review)
DP22-0084

TRANSMITTAL DATE: April 20, 2022

DUE DATE: May 05, 2022

The Zoning Review Section conditionally approves the grading plan for this project. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised grading plan to verify that those changes do not affect any zoning requirements.

CONTENT REQUIREMENTS

1. COMMENT: 2-06.4.3 – Provide the development package case number, DP22-0084, adjacent to the title block on all sheets.

If you have any questions about this transmittal, please contact Nicholas Ross at Nocholas.Ross@tucsonaz.gov.

To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
04/21/2022 SBLOOD1 ENGINEERING REVIEW Reqs Change Sheet 1
1. Provide the contact information for the Geotechnical Engineer.
2. Please include a 3" x 5" block in the lower right quadrant for the approval stamp on all sheets.
3. Provide adjacent parcel information to the west on the key map.
4. Please ensure water valves in legend plot correctly.
5. Please shift utility legend text down one line item as they are all incorrect.
6. All effort should be given towards matching the comments shown on all other adjacent parcels and offsite grading plan submittals.
7. Please add squiggly flow arrows to the legend, as well as all other symbols used.
8. The 100-yr flood inundation limit is shown within the legend, but I do not see the line in plan view. Please verify.
9. Please add "SSL, RSL" to the abbreviations list.
10. Please revise the retaining wall legend item or the black phaselines in plan view as they appear the same.
11. Please add reference number DP22-0084 to each sheet.

Sheet 3
12. Provide site boundary bearing.
13. Please show lot number on lot 71.
14. The pad drop between lot 59 and lot 11 is greater than 2'. Therefore, the section called out should be C8.
15. The pad drop between lot 69 and 18 exceeds 3'. Revise to meet section 8 requirements or update section callout.
16. Please include all lot dimensions.

Sheet 4
17. Please include the 100-yr flood inundation limit as shown in the legend.
18. Identify all high and low points.
19. Please label the storm drain size, length, and slope.
20. Please provide scupper details.

Sheet 5
21. Provide the height for the step in the garage.
22. Please provide section D-D as referenced in typical finish lot grading detail.
23. Please show on the Typical Finish Lot Grading Detail, a minimum slope away from buildings of 1%.

Review and Comments provided by third party engineer reviewers under contract with the City of Tucson. For Questions or Concerns contact:
Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov
06/08/2022 AWARNER1 NPPO REVIEW Reqs Change CDRC TRANSMITTAL
TO: Planning and Development Services Department, Plans Coordination
FROM: Anne Warner, RLA
PDSD Landscape/Native Plant Preservation Section

PROJECT: La Estancia West
ACTIVITY NO: DP22-0084

TRANSMITTAL DATE: June 8, 2022
DUE DATE: May 5, 2022
COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Landscape Review Section comments were addressed.
This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants and water harvesting.

1. The monitor is responsible for an assessment of the condition of the site's plants one year after the final inspection has been performed on the site. The monitor shall visit the site and prepare a report on plant status, including general plant condition, the identification of plants under stress and the appropriate method to relieve the stress, and recommendations for replacement of plants that are dead or dying. Dead or dying plants must be replaced with the same size plant at a one-to-one ratio of like genus and species. Copies of the report must be submitted to the site owner/developer and to PDSD. The owner must respond to the plant needs as outlined in the status report within six months of report submittal or within a shorter period if required to improve the health of stressed plants and prevent plant loss.

2. Please identify the project monitor prior to any grading activities, UDC 7.7.5. On-monitoring of all aspects of site clearing, grading, plant protection, preservation, salvage, and mitigation must be provided during project construction at the expense of the developer for all residential development that is over five acres and for all commercial and industrial development that is over one acre . The monitoring must be performed by an individual who is qualified in arid lands native plant resource identification and protection as specified in UDC Section 7.7.4.D, Professional Expertise. The monitor must provide periodic progress reports to the developer outlining the status of work accomplished and any problems encountered. A copy of these reports must be submitted to the PDSD for the project file.


RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package

YOUR NEXT STEPS: Submit documents to the Filedrop
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
Select "Existing Application"
1) Comment Response Letter (your response to
the reviewer's Requires changes comments)
2) Plan Set (or individual sheets)
3) Any other items requested by review staff

If you have any questions, please contact me at anne.warner@tucsonaz.gov
06/16/2022 SBEASLE1 ZONING-DECISION LETTER WRITE DECISION LETTER Reqs Change Email from: COTDSDPermits
To: Andie Hemmah
Thu 6/16/2022 11:54 AM

REVIEW NOTICE
Returned for Corrections: DP22-0084

Project Description: Grading: La Estancia, Parcel 8, residential subdivision. 6670 E CAMINO BOLEADORAS

FEE BALANCE: $ 2,511.97
Please pay at a minimum, the REVIEW category fees.
A payment is required before your next submittal.

ONLINE PAYMENTS
** If amount doesn't match "Fee Balance", check back in a few hours **
https://www.tucsonaz.gov/pdsd/fees
1- Click on: Pay Planning & Permit Fees
2- Enter Permit Nbr, example: dp20-0000
(not case-sensitive but a hyphen-dash- is needed)
3- Business/Individual Name: Leave this field blank
4- "Continue"
5- In the Pay column - check the boxes
6- "Continue"

YOUR NEXT STEPS
1. SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW

2. Title your SECOND submittal documents accordingly, example: 2_Comment Response Letter

3. UPLOAD A RESUBMITTAL to Filedrop:
- Comment Response Letter (your response to REQUIRES CHANGE comments)
- Plan Set (all pages, full set, even if no changes were made)
- Any other documents requested by review staff

- FILEDROP
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
- "Existing Application"
- "Permit Number" field: enter the number (and any notes for our staff)
- Select "PLANS" for all documents

Thank you.
Sharon Beasley, Certified Building Technician

City of Tucson, Planning & Development Services Dept.
Email: COTDSDpermits@TucsonAz.gov
(for development packages, land splits, Thursday Presubmittal meetings)

Email: PDSDinquiries@TucsonAz.gov
(for building permits)