Permit Number: DP22-0080
Parcel: 14136683A

Review Status: Completed

Review Details: GRADING

Permit Number - DP22-0080
Review Name: GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/20/2022 STEVE SHIELDS ZONING REVIEW Approv-Cond PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: La Estancia Parcel 7 – Grading Only
Development Package (1st Review)
DP22-0080

TRANSMITTAL DATE: April 20, 2022

DUE DATE: May 05, 2022

The Zoning Review Section conditionally approves the grading plan for this project. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised grading plan to verify that those changes do not affect any zoning requirements.

CONTENT REQUIREMENTS

1. COMMENT: 2-06.4.3 – Provide the development package case number, DP22-0080, adjacent to the title block on all sheets.

If you have any questions about this transmittal, please contact Nicholas Ross at Nocholas.Ross@tucsonaz.gov.

To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
04/21/2022 SBLOOD1 ENGINEERING REVIEW Reqs Change Sheet 1
1. Please provide disturbed area in both SF and acres.
2. Please provide contact information for Geotechnical Engineer.
3. Please include a 3" x 5" block in the lower right quadrant for the approval stamp on all sheets.
4. Please add "SSL, RSL" to the abbreviations list.
5. Please provide adjacent parcel information to the key map.
6. Please ensure water valves in legend plot correctly.
7. Please shift utility legend text down one line item as they are all incorrect.
8. All effort should be given towards matching the comments shown on all other adjacent parcels and offsite grading plan submittals.
9. Please add squiggly flow arrows to the legend, as well as all other symbols used.
10. The 100-yr flood inundation limit is shown within the legend, but I do not see the line in plan view. Please verify.
11. Please revise the retaining wall legend item or the black phaselines in plan view as they appear the same.
12. Please add reference number DP22-0080 to each sheet.

Sheet 2
13. General Note #2: Please provide gross area in both SF and acres.

Sheet 3
14. Please provide grade change elevations in front of lot 60.
15. Elevation drop from PAD 70 to PAD 85 and from PAD 70 to PAD 84 are less than 2'. C8 is not apply. Please provide appropriate section (Example: add a new section for less than 2' PAD to PAD drop, with grouted rip rap).
16. Provide site boundary bearing and distance.

Sheet 4
17. At lot 32: It shows section C4 crossing the basin. Please clarify if it should be section C5 instead of C4.
18. For all proposed basins, please label, WSEL limit, proposed top and bottom elevation, volume and flow rate.
19. Please provide storm drain invert elevations and slope.
20. Lot 11 and Lot 59 have 2.2' PAD to PAD drop. Cross Section C7 is not apply. Please provide appropriate cross section.
21. Lot 16 and Lot 67 have 2.4' PAD to PAD drop. Cross Section C7 is not apply. Please provide appropriate cross section.
22. S. Via Bombachas, STA 11+00 to 14+00: Please identify HP elevation.
23. Please provide culvert info such as flowlines and section.
24. Please identify the dashed road appearing behind all linework.
25. Please include all lot dimensions.

Sheet 5
26. Please provide section D-D.
27. Please provide height for step in garage.

Review and Comments provided by third party engineer reviewers under contract with the City of Tucson. For Questions or Concerns contact:
Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov
06/08/2022 AWARNER1 NPPO REVIEW Reqs Change CDRC TRANSMITTAL
TO: Planning and Development Services Department, Plans Coordination
FROM: Anne Warner, RLA
PDSD Landscape/Native Plant Preservation Section

PROJECT: La Estancia
ACTIVITY NO: DP22-0080

TRANSMITTAL DATE: June 8, 2022
DUE DATE: May 5, 2022
COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Landscape Review Section comments were addressed.
This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants and water harvesting.

1. The monitor is responsible for an assessment of the condition of the site's plants one year after the final inspection has been performed on the site. The monitor shall visit the site and prepare a report on plant status, including general plant condition, the identification of plants under stress and the appropriate method to relieve the stress, and recommendations for replacement of plants that are dead or dying. Dead or dying plants must be replaced with the same size plant at a one-to-one ratio of like genus and species. Copies of the report must be submitted to the site owner/developer and to PDSD. The owner must respond to the plant needs as outlined in the status report within six months of report submittal or within a shorter period if required to improve the health of stressed plants and prevent plant loss.

2. Please identify the project monitor prior to any grading activities, UDC 7.7.5. On-monitoring of all aspects of site clearing, grading, plant protection, preservation, salvage, and mitigation must be provided during project construction at the expense of the developer for all residential development that is over five acres and for all commercial and industrial development that is over one acre . The monitoring must be performed by an individual who is qualified in arid lands native plant resource identification and protection as specified in UDC Section 7.7.4.D, Professional Expertise. The monitor must provide periodic progress reports to the developer outlining the status of work accomplished and any problems encountered. A copy of these reports must be submitted to the PDSD for the project file.


RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package

YOUR NEXT STEPS: Submit documents to the Filedrop
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
Select "Existing Application"
1) Comment Response Letter (your response to
the reviewer's Requires changes comments)
2) Plan Set (or individual sheets)
3) Any other items requested by review staff

If you have any questions, please contact me at anne.warner@tucsonaz.gov
06/16/2022 SBEASLE1 ZONING-DECISION LETTER WRITE DECISION LETTER Reqs Change Email from: COTDSDPermits
To: Andie Hemmah
Thu 6/16/2022 11:43 AM

REVIEW NOTICE
Returned for Corrections: DP22-0080

Project Description: Grading - La Estancia, Parcel 7, Lots 1 thru 107, and Common Areas A7, B7, C7, and D7.
6670 E CAMINO BOLEADORAS

Fee Balance: $0 (zero) Thank you for the payment.

YOUR NEXT STEPS
1. SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW

2. Title your SECOND submittal documents accordingly, example: 2_Comment Response Letter

3. UPLOAD A RESUBMITTAL to Filedrop:
- Comment Response Letter (your response to REQUIRES CHANGE comments)
- Plan Set (all pages, full set, even if no changes were made)
- Any other documents requested by review staff

- FILEDROP
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
- "Existing Application"
- "Permit Number" field: enter the number (and any notes for our staff)
- Select "PLANS" for all documents

Thank you.