04/13/2022 SBEASLE1 START PLANS SUBMITTED Completed
04/20/2022 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: Tropical Smoothie Valencia
Development Package (1st Review)
DP22-0078

TRANSMITTAL DATE: April 20, 2022

DUE DATE: May 03, 2022

COMMENTS: Please resubmit revised drawings and a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is March 30, 2023.

CONTENT REQUIREMENTS

1. COMMENT: 2-06.4.3 – Provide the development package case number, DP22-0078, adjacent to the title block on all sheets.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

2. COMMENT: 2-06.4.9.H.5.d – It does not appear that the southern most short-term bicycle parking meets the requirements of UDC Article 7.4.9.C.2.a. Clearly demonstrate that this requirement is met.

3. COMMENT: 2-06.4.9.O – The street perimeter yard setback listed under Setbacks, Landscape Borders and Screening note 1 is not correct. As Valencia is designated as an Arterial Gateway on the COT MS&R map this site does not qualify for Established Area Setbacks, see UDC Article 11.4.6 definition of Established Area Setback. The street perimeter yard setback should be listed as 21’ or the height of the proposed exterior building wall, great of the two, as measured from the back of future curb. Zoning acknowledges the platted setback requirement shown on the plan.

If you have any questions about this transmittal, please contact Nicholas Ross at Nocholas.Ross@tucsonaz.gov.

To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
04/29/2022 JVINCEN1 FIRE REVIEW Approved
05/02/2022 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
05/12/2022 AWARNER1 LANDSCAPE REVIEW Approv-Cond Please add a note at the existing basin to remove existing d.g. at the bottom and replace with 4" or greater rock to mitigate sediment.
06/24/2022 SBEASLE1 PIMA COUNTY - ADDRESSING PIMA COUNTY - ADDRESSING Passed Email from: Nicholas Jordan <Nicholas.Jordan@pima.gov> on behalf of Addressing <Addressing@pima.gov>
To: CDRC
Thu 6/23/2022 1:29 PM

Please remove Pima County Addressing from the review queue for this activity. The project does not require review by Pima County Addressing.
Thank you

Nicholas Jordan
Site Review Project Manager - Addressing Official
07/11/2022 LOREN MAKUS ENGINEERING REVIEW Approved
07/12/2022 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change email from: COTDSDPermits
To: James McMurtrie
Tue 7/12/2022 10:08 AM

REVIEW NOTICE

Returned for Corrections: DP22-0078
Site/Grading/Swppp - Tropical Smoothie Valencia. 3200 E VALENCIA RD

Fee Balance: $0 (zero) Thank you for the payment.

YOUR NEXT STEPS
1. SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW

2. Title your SECOND submittal documents accordingly, example: 2_Comment Response Letter

3. UPLOAD A RESUBMITTAL to Filedrop:
- Comment Response Letter (your response to REQUIRES CHANGE comments)
- Plan Set (all pages, full set, even if no changes were made)
- Any other documents requested by review staff

FILEDROP
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
- "Existing Application"
- "Permit Number" field: enter the number (and any notes for our staff)
- Select "PLANS" for all documents


Sharon Beasley, Certified Permit Technician

City of Tucson, Planning & Development Services Dept.
Email: COTDSDpermits@TucsonAz.gov
(for development packages, land splits, Thursday Presubmittal meetings)
Email: PDSDinquiries@TucsonAz.gov
(for building permits)