Permit Number: DP22-0037
Parcel: 111041550

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP22-0037
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/07/2022 SBEASLE1 START PLANS SUBMITTED Completed
03/07/2022 SBEASLE1 ENGINEERING REVIEW Approved Engineering was approved by Loren Makus during the OK to Submit.
03/17/2022 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
03/23/2022 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: Kleindale MF Development
Development Package (1st Review)
DP22-0037

TRANSMITTAL DATE: March 23, 2022

DUE DATE: March 30, 2022

COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is February 24, 2023

2-06.3.0 FORMAT REQUIREMENTS

CONTENT REQUIREMENTS

1. COMMENT: 2-06.4.2.D – Provide the page number and total number of pages, 2 of 4, on the second sheet.

2. COMMENT: 2-06.4.3 – Provide the development package case number, DP22-0037, adjacent to the title block on all sheets.

2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

2-06.4.7.A - Zoning and Land Use Notes

3. COMMENT: 2-06.4.7.A.4 – The Use Specific Standard listed under General Note 3 is not correct. Review UDC TABLE 4.8-2: PERMITTED USES - URBAN RESIDENTIAL ZONES, Residential Land Use Group With Land Use Class/Type: Multifamily Development, R-3 Zone and provide the correct Use Specific Standard.

4. COMMENT: 2-06.4.7.A.6.a – Remove General Note 11 from the plan as this site does not border on a street designated on the DOT MS&R map.

2-06.4.8 - Existing Site Conditions
The following information shall be provided on the plan/plat drawing to indicate the existing conditions on site and within 50 feet of the site. On sites bounded by a street with a width of 50 feet or greater, the existing conditions across the street will be provided.

5. COMMENT: 2-06.4.8.C – Provide the following information for Kleindale Ave on the plan: right-of-way width, dimensioned width of paving, curbs, curb cuts, and sidewalks.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

6. COMMENT: 2-06.4.9.H.5 – As you are reconfiguring the majority of the vehicle use area provide a fully dimensioned vehicle use area. This shall include PAAL widths along with parking space depths.

7. COMMENT: 2-06.4.9.H.5 – There appears to be a roof overhang on Bldg 4 that overhangs the PAAL. The over hang either needs to meet UDC Article 7.4.6.E.2 or 7.4.6.F.2.b, clearly demonstrate that one of these requirements is met.

8. COMMENT: 2-06.4.9.H.5.a – Per 2018 IBC Chapter 11 Section 1106.5 For every six of fraction of six accessible parking spaces at least one shall be a van-accessible parking space. Provide the number of required and provided van-accessible spaces in the parking calculation. Also, clearly show that the requirements of ICC A117.1-2009 Section 502 are met.

9. COMMENT: 2-06.4.9.H.5.a – Per UDC Article 7.4.6.D.a The minimum Space Depth for a vehicle parking space is 18’-0” revise the detail to show the correct depth.

10. COMMENT: 2-06.4.9.H.5.d – Sheet 4 there is a call out for “SHORT TERM BIKE PARKING (2)” located in the southeast corner of the site that appears to point to a sidewalk, clarify what is proposed.

11. COMMENT: 2-06.4.9.H.5.d – Revise the provided long-term bicycle parking to show 13 provided with in the individual units, you do not need to provide any external long-term on site.

12. COMMENT: 2-06.4.9.H.5.d – The 2’-0” dimension shown on the “typical short term” detail is not shown correctly and should be shown from the edge of the rack not the center, see UDC Figure 7.4.9-C.

13. COMMENT: 2-06.4.9.O – The street perimeter yard setback shown on sheet 1 is not correct and should be 20 feet or one and one-half the height of the proposed wall (H), greater of the two, see UDC Article 6.4.5.C.1.a.

14. COMMENT: 2-06.4.9.O – The south perimeter yard setback shown on sheet 1 is not correct and should be listed as 10 feet or 3/4 the height of the proposed wall (H), greater of the two, see UDC Article 6.3.3.C and Table 6.3-2.A.

15. COMMENT: 2-06.4.9.R – As you are proposing a new use for Bldg #4, TSM Section 7-01.2.A demonstrate on the plan that the requirements of TSM Sections 7-01.3.2, 3.3, 4.1, 4.2 & 4.3 are met.

If you have any questions about this transmittal, please contact Nicholas Ross at Nocholas.Ross@tucsonaz.gov.

To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
03/24/2022 JPEELDA1 FIRE REVIEW Approved Waiting to hear from Ryan
04/29/2022 AWARNER1 LANDSCAPE REVIEW Reqs Change CDRC TRANSMITTAL
TO: Planning and Development Services Department, Plans Coordination
FROM: Anne Warner, RLA
PDSD Landscape/Native Plant Preservation Section

PROJECT: Kleindale MF dev
ACTIVITY NO:
Parcel: 111-04-1550
Zoning: R-3
Existing Use: Multi-family
Proposed Use: Multi-family

TRANSMITTAL DATE: April 29, 2022
DUE DATE: March 30, 2022
COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Landscape Review Section comments were addressed.
This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants and water harvesting.

1. One tree is required for the new parking spaces to provide shade over the asphalt. Existing trees can count towards the requirement, but must be shown on the plans. UDC 7.6.1.A.3

2. Ensure that Zoning and Engineering comments are addressed prior to landscape section approval.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package

YOUR NEXT STEPS: Submit documents to the Filedrop
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
Select "Existing Application"
1) Comment Response Letter (your response to
the reviewer's Requires changes comments)
2) Plan Set (or individual sheets)
3) Any other items requested by review staff

If you have any questions, please contact me at anne.warner@tucsonaz.gov
04/29/2022 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change Email from: COTDSDPermits
To: Ryan
Fri 4/29/2022 12:15 PM

REVIEW NOTICE
Returned for Corrections: DP22-0037

DESCRIPTION: SITE - Kleindale MF Dev. Existing buildings to be improved for introduction of new units. Augmentation of parking layout for new parking spaces based on increased number of dwelling units. All else existing to remain.
3414 E KLEINDALE RD

FEE BALANCE: $ 2,102.38
Please pay at a minimum, the REVIEW category fees.
A payment is required before your next submittal.

ONLINE PAYMENTS
** If amount doesn't match "Fee Balance", check back in a few hours **
https://www.tucsonaz.gov/pdsd/fees
1- Click on: Pay Planning & Permit Fees
2- Enter Permit Nbr, example: dp20-0000
(not case-sensitive but a hyphen-dash- is needed)
3- Business/Individual Name: Leave this field blank
4- "Continue"
5- In the Pay column - check the boxes
6- "Continue"

YOUR NEXT STEPS
1. SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW

2. Title your SECOND submittal documents accordingly, example: 2_Comment Response Letter

3. UPLOAD A RESUBMITTAL to Filedrop:
- Comment Response Letter (your response to REQUIRES CHANGE comments)
- Plan Set (all pages, full set, even if no changes were made)
- Any other documents requested by review staff

- FILEDROP:
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
- "Existing Application"
- "Permit Number" field: enter the number (and any notes for our staff)
- Select "PLANS" for all documents

Thank you.
Sharon Beasley, Certified Permit Specialist

City of Tucson, Planning and Development Services
Email: COTDSDpermits@TucsonAz.gov
04/29/2022 SBEASLE1 PIMA COUNTY - ADDRESSING PIMA COUNTY - ADDRESSING Needs Review